Logotipo del repositorio

Publicación:
CARDIAC ARRHYTHMIAS DETECTION WITH 12-LEAD ECG USING A MULTIMODAL NEURAL NETWORK

dc.contributor.advisorRodriguez Rodriguez, Harold Hernando
dc.contributor.advisorSantos Ortiz, Camilo Andres
dc.contributor.advisorFajardo Ariza, Carlos Augusto
dc.contributor.authorRuíz González, Karla Vanessa
dc.contributor.authorMoreno Ortiz, Didier Julian
dc.contributor.evaluatorQuintero Muñoz, Jorge Eduardo
dc.contributor.evaluatorSepulveda Sepulveda, Franklin Alexander
dc.date.accessioned2025-11-21T16:29:21Z
dc.date.available2025-11-21T16:29:21Z
dc.date.created2025-11-19
dc.date.issued2025-11-19
dc.description.abstractLas enfermedades cardiovasculares son la principal causa de muerte a nivel mundial, siendo las arritmias cardíacas una de las condiciones más frecuentes y difíciles de diagnosticar. El diagnóstico se basa tradicionalmente en electrocardiogramas (ECG) de 12 derivaciones, los cuales generan grandes volúmenes de datos que requieren interpretación experta y pueden saturar al personal clínico en entornos de alta demanda. Este estudio propone una red neuronal multimodal para la detección de arritmias a partir de ECG de 12 derivaciones, incorporando interpretabilidad para identificar las derivaciones más influyentes. El modelo se entrenó inicialmente con datos de los desafíos PhysioNet/Computing in Cardiology 2020 y 2021, utilizando una red neuronal convolucional basada exclusivamente en la señal del ECG, y se analizó mediante Shapley Additive Explanations para jerarquizar la importancia de las derivaciones. Posteriormente, se reentrenó y evaluó empleando configuraciones de 6, 4 y 2 derivaciones, tanto en modelos basados únicamente en la señal del ECG como en configuraciones multimodales que combinan el ECG con características demográficas y temporales. Los resultados muestran que los modelos de 4 y 6 derivaciones alcanzaron puntajes F1 comparables o superiores a la línea base de 12 derivaciones, mientras que el modelo de 2 derivaciones mantuvo un rendimiento estable. La métrica oficial del PhysioNet/Computing in Cardiology Challenge alcanzó un valor máximo de 0.9074. El enfoque multimodal no produjo mejoras significativas, lo que resalta la contribución limitada de las características adicionales. Estos hallazgos demuestran la viabilidad de los modelos con derivaciones reducidas como alternativas eficientes y accesibles para la clasificación de arritmias.
dc.description.abstractenglishCardiovascular diseases are the leading cause of death worldwide, with cardiac arrhythmias among the most prevalent and diagnostically challenging conditions. Diagnosis traditionally relies on 12-lead electrocardiograms (ECG), which produce large amounts of data requiring expert interpretation and may overwhelm clinicians in high-demand settings. This study proposes a multimodal neural network for arrhythmia detection from 12-lead ECGs, incorporating interpretability to identify the most influential leads. The model was initially trained on data from the PhysioNet/Computing in Cardiology Challenges 2020 and 2021 using a signal-only convolutional neural network and analyzed with Shapley Additive Explanations to rank lead importance. It was then retrained and evaluated using 6, 4, and 2 leads, in both signal-only and multimodal configurations combining ECGs with demographic and temporal features. Results show that 4- and 6-lead models achieved F1-scores comparable to or higher than the 12-lead baseline, while the 2-lead model maintained stable performance. The official PhysioNet/Computing in Cardiology Challenge metric reached 0.9074 at best. The multimodal approach did not yield significant improvements, underscoring the limited contribution of the additional features. These findings demonstrate the feasibility of reduced-lead models as efficient and accessible alternatives for arrhythmia classification.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Electrónico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/46650
dc.language.isoeng
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programIngeniería Electrónica
dc.publisher.schoolEscuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.subjectArritmias cardíacas
dc.subjectECG
dc.subjectMultimodal
dc.subjectAprendizaje profundo
dc.subjectInterpretabilidad
dc.subject.keywordCardiac Arrhythmias
dc.subject.keywordECG
dc.subject.keywordMultimodal
dc.subject.keywordDeep Learning
dc.subject.keywordInterpretability
dc.titleCARDIAC ARRHYTHMIAS DETECTION WITH 12-LEAD ECG USING A MULTIMODAL NEURAL NETWORK
dc.title.englishCARDIAC ARRHYTHMIAS DETECTION WITH 12-LEAD ECG USING A MULTIMODAL NEURAL NETWORK
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
190.08 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
156.36 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
288.02 KB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
2.17 KB
Formato:
Item-specific license agreed to upon submission
Descripción:

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031