Publicación: Propuesta de diseño de un socket para usuarios con amputación transfemoral, basado en la integración de técnicas de ingeniería inversa, modalidad practica empresarial en la empresa líneas hospitalarias S.A.S.
| dc.contributor.advisor | López Gualdron, Clara Isabel | |
| dc.contributor.advisor | Bautista Rojas, Luis Eduardo | |
| dc.contributor.author | Machuca Gelvez, Jesus Alexis | |
| dc.date.accessioned | 2024-03-03T22:12:55Z | |
| dc.date.available | 2015 | |
| dc.date.available | 2024-03-03T22:12:55Z | |
| dc.date.created | 2015 | |
| dc.date.issued | 2015 | |
| dc.description.abstract | Con el fin de solucionar los inconvenientes que se presentan por los cambios de volumen del muñón, en amputados del miembro inferior del caso transfemoral y con la integración de tecnologías de ingeniería inversa, al proceso de fabricación artesanal de sockets. Este proyecto plantea el diseño de un nuevo socket aplicado a un caso de estudio para la empresa Líneas Hospitalarias SAS. Para esto se implementó en el laboratorio de órtesis y prótesis de la empresa una metodología de 4 etapas: 1. Ingeniería inversa. Con la técnica de triangulación se reconstruyo el muñón del caso de estudio para la obtención de un modelo digital. 2. Construcción digital del socket base. Utilizando herramientas CAD y el modelo digital obtenido, se construyó virtualmente el socket actual del caso de estudio. 3 Diseño. Se desarrollaron diferentes conceptos de socket con la propuesta de valor del ajuste al cambio de volumen del muñón, de los cuales se seleccionó una alternativa final, que fue desarrollada con base al socket base construido con herramientas CAD. 4. Verificación y testeo. Finalmente la alternativa final fue prototipada y utilizada en el caso de estudio para pruebas de usabilidad. Los resultados muestran que fue posible desarrollar un diseño de socket con el modelo de integración de tecnologías, este dispositivo fue anatómicamente adecuado para la geometría del muñón, y se comprobó con pruebas estáticas y dinámicas que el grado de confort es similar a un socket convencional. De igual forma que el sistema de ajuste desarrollado tuvo una aceptación adecuada en el paciente del caso de estudio y se evidencio la capacidad de ajustarse a los cambios de volumen identificados. _______________________ | |
| dc.description.abstractenglish | In order to solve the problems presented by changes in residual limb volume, on lower limb amputees case of transfemoral and the integration of reverse engineering technologies, to the process of handmade sockets. This project involves the design of a new socket applied to a case study for the company Lineas Hospitalarias SAS. To this was implemented in the laboratory of orthotic and prosthetic Company a methodology of 4 stages: 1. Reverse engineering. With the technique of triangulation the stump of case study to obtaining a digital model is constructed. 2. Digital reconstruction of the socket base. Using CAD tools and the digital model obtained is virtually built the current socket of the case study. 3. Design. Socket different concepts were developed with the value proposition of setting the volume change of the stump, of which a final option was selected, which it was developed based on the basic CAD tools built socket. 4. Verification and testing. Finally the final alternative was prototyped and used in the case study for usability testing. The results show that it was possible to develop a socket design with technology integration model, this device was anatomically suited to the geometry of the stump, and it was found with static and dynamic tests the level of comfort is similar to a conventional socket. Similarly the adjustment system developed had adequate patient acceptance Case Study and was evidenced the ability to adjust to changes volume identified. _____________________ | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Diseñador Industrial | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/33209 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Diseño Industrial | |
| dc.publisher.school | Escuela de Diseño Industrial | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Prótesis Transfemoral | |
| dc.subject | Amputación | |
| dc.subject | Diseño De Socket | |
| dc.subject | Cambios De Volumen. | |
| dc.subject.keyword | Transfemoral Prosthesis | |
| dc.subject.keyword | Amputation | |
| dc.subject.keyword | Socket Design | |
| dc.subject.keyword | Volumen Changes. | |
| dc.title | Propuesta de diseño de un socket para usuarios con amputación transfemoral, basado en la integración de técnicas de ingeniería inversa, modalidad practica empresarial en la empresa líneas hospitalarias S.A.S. | |
| dc.title.english | Proposed design of a socket to transfemoral amputees users. integration based on reverse engineering techniques. business practice mode in the company lineas hospitalarias sas. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |