Logotipo del repositorio

Publicación:
Flujos Normalizantes Condicionales para la estimación del espectro de muones.

dc.contributor.advisorNúñez de Villavicencio Martínez, Luis Alberto
dc.contributor.advisorSarmiento Cano, Christian Andrés
dc.contributor.authorOrduz Carvajal, Cristian Vladimir
dc.contributor.authorAlmanzar Quintero, Jhon Jairo
dc.contributor.evaluatorRomo Bucheli, David Edmundo
dc.contributor.evaluatorBenavides Arévalo, Bernardo Andrés
dc.date.accessioned2026-08-20T11:27:03Z
dc.date.created2026-08-18
dc.date.issued2026-08-18
dc.description.abstractLa muografía es una técnica de imagen no invasiva que infiere la estructura interna de grandes objetos mediante la atenuación del flujo de muones atmosféricos. Su viabilidad depende de estimar con precisión el espectro muónico del sitio de interés, el cual varía de forma no lineal con la altitud y el campo geomagnético. Los métodos tradicionales presentan limitaciones opuestas: simulaciones como ARTI/CORSIKA son precisas pero lentas, superando las once horas por sitio, mientras que las parametrizaciones analíticas son rápidas pero restringidas a condiciones geofísicas específicas. Esta brecha motivó la pregunta central: ¿pueden los flujos normalizantes condicionales replicar la precisión de ARTI con un costo computacional significativamente menor? Para responderla, se generó un conjunto de datos balanceado mediante muestreo estratificado sobre 45 ubicaciones en 25 países, cubriendo altitudes entre 0 y 5230 m s.n.m. e intensidades geomagnéticas entre 22,5 y 56,75 muT. Con base en este conjunto, se entrenó un modelo bidimensional con transformaciones autoregresivas enmascaradas y splines racionales cuadráticas, capaz de estimar la distribución conjunta de energía y ángulo cenital condicionada por variables geofísicas. Adicionalmente, el modelo fue integrado en una plataforma web Angular–FastAPI para consultar, generar y visualizar espectros según su ubicación geográfica. El modelo alcanzó un error relativo absoluto promedio de 0,1160 en validación y 0,0925 en prueba. Las mayores discrepancias se concentraron en el intervalo energético de 10^3 a 10^4 GeV y en los extremos angulares, regiones de baja densidad donde el propio ARTI presenta variabilidad estadística inherente a su naturaleza Monte Carlo. En eficiencia, el tiempo de generación se redujo de 8 horas 50 minutos por ciudad a un tiempo promedio de 60 segundos por ciudad, con aceleraciones superiores a 500x. Estos resultados respaldan la viabilidad de los flujos normalizantes condicionales como modelo sustituto para la estimación del espectro de muones en aplicaciones de muografía.
dc.description.abstractenglishMuography is a non-invasive imaging technique that infers the internal structure of large objects from the attenuation of atmospheric muon flux. Its feasibility depends on accurately estimating the muon spectrum at the site of interest, which varies nonlinearly with altitude and the geomagnetic field. Traditional methods have opposing limitations: simulations like ARTI/CORSIKA are accurate but take a long time, exceeding eleven hours per site, while analytical parameterizations are fast but restricted to specific geophysical conditions. This gap motivated the central question: can conditional normalizing flows replicate the accuracy of ARTI with a significantly lower computational cost? To address this, a balanced dataset was generated through stratified sampling over 45 locations in 25 countries, covering altitudes between 0 and 5230 m a.s.l. and geomagnetic intensities between 22.5 and 56.75 muT. Based on this dataset, a bidimensional model was trained using masked autoregressive transformations and rational quadratic splines, capable of estimating the joint distribution of energy and zenith angle conditioned on geophysical variables. Additionally, the model was integrated into an Angular–FastAPI web platform to query, generate, and visualize spectra from a geographic location. The model achieved a mean absolute relative error of 0.1160 on the validation set and 0.0925 on the test set. The largest discrepancies were concentrated in the energy range of 10^3 to 10^4 GeV and at angular extremes, low-density regions where ARTI itself shows statistical variability due to its Monte Carlo nature. In terms of efficiency, generation time was reduced from 8 hours 50 minutes per city to an average time of 60 seconds per city, with speedups exceeding 500x. The results support the viability of conditional normalizing flows as a surrogate model for estimating the muon spectrum in muography applications.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero de Sistemas
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/48121
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programIngeniería de Sistemas
dc.publisher.schoolEscuela de Ingeniería de Sistemas e Informática
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectFlujos normalizantes condicionales
dc.subjectPrototipo de plataforma web
dc.subjectMuografía
dc.subjectARTI/CORSIKA
dc.subjectMuones
dc.subjectCosto computacional
dc.subject.keywordConditional normalizing flows
dc.subject.keywordWeb platform prototype
dc.subject.keywordMuography
dc.subject.keywordARTI/CORSIKA
dc.subject.keywordMuons
dc.subject.keywordComputational cost
dc.titleFlujos Normalizantes Condicionales para la estimación del espectro de muones.
dc.title.englishConditional Normalazing Flows for muon spectrum estimation.
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Nota de Proyecto.pdf
Tamaño:
541.28 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
3.18 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Carta Autorización de Uso.pdf
Tamaño:
156.7 KB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
2.17 KB
Formato:
Item-specific license agreed to upon submission
Descripción:

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031