Publicación: Aplicación de la técnica de ultrasonido para la estimación de la perdida de espesor en la superficie externa de una pieza tubular
| dc.contributor.advisor | Quintero Ortiz, Luz Amparo | |
| dc.contributor.advisor | Mendoza Gonzalez, Edward Yesith | |
| dc.contributor.author | Catalina Moros, Adriana | |
| dc.contributor.author | Torres Benitez, Elkin Yesid | |
| dc.date.accessioned | 2024-03-03T17:32:37Z | |
| dc.date.available | 2009 | |
| dc.date.available | 2024-03-03T17:32:37Z | |
| dc.date.created | 2009 | |
| dc.date.issued | 2009 | |
| dc.description.abstract | Este trabajo presenta el estudio de la aplicación de la técnica de ultrasonido por inmersión para la estimación de la pérdida de espesor en la superficie externa de escalerillas calibradas ASTM E797-05 (en milímetro y en pulgadas) y de una probeta tipo tubular, utilizando un transductor no focalizado. Primero se realizaron ensayos con cada una de las escalerillas calibradas, las cuales cuentan con cuatro pasos descendentes, realizándose un barrido desde el espesor mayor hasta el espesor menor de cada una de estas, con pasos de 1 o 2 milímetros registrándose así la posición de la columna de agua, la cual determinó la pérdida de espesor en la superficie externa de cada escalerilla. Con base en estos datos se realizó la representación de la variación de espesores para cada uno de los escalones que tiene las escalerillas. Posteriormente, se realizó de la misma forma el barrido para la probeta tipo tubular, con pasos de 1 milímetro, registrándose en cada paso la posición de la columna de agua, la cual determinó la pérdida de espesor en la superficie externa de la probeta tubular. Al igual que con las escalerillas, se realizó la representación de la variación de espesores para cada uno de los escalones que tiene la probeta. De acuerdo con los resultados obtenidos, se pudo comprobar que la técnica de ultrasonido por inmersión, permite determinar cambios de espesor de hasta 2[mm] con buena precisión en piezas planas (escalerillas), además es una herramienta adecuada en la determinación de las pérdidas de espesor en la superficie de las probetas tubulares, presentando menor error en la determinación de pérdida de espesores mayores al 20%. | |
| dc.description.abstractenglish | This paper presents a study of the implementation of immersion ultrasound technique to estimate the lost of thickness on the outer surface of ladders calibrated ASTM E797-05 (in mm and inches) and a tubular cylinder, using a Unfocused transducer. First tests were performed with each of the ladders calibrated, which has four steps down, carrying out a sweep from the greater thickness to the thickness under each of these, in steps of 1 or 2 mm and recorded the position of the water column, which determined the lost of thickness on the outer surface of each ladder. Based on these data was made representing the thickness variation for each of the steps that has the ladder. Later, there were just as sweeping for the tubular specimen, with steps of 1 mm, recorded at each step the position of the water column, which determined the lost of thickness on the outer surface of the specimen tube. As with the stairs, there was representation of the variation in thickness for each of the steps that have the probe. According to the results, it was found that the ultrasonic immersion technique, to determine changes in thickness up to 2 [mm] with good precision flat parts (ladders), also is a valuable tool in determining the losses thickness on the surface of the tubular specimens, presenting minor error in the determination of loss of thickness greater than 20%. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Metalúrgico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/22343 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Metalúrgica | |
| dc.publisher.school | Escuela de Ingeniería Metalúrgica y Ciencia de Materiales | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Ultrasonido por Inmersión | |
| dc.subject | Perdidas de espesor | |
| dc.subject | Acero al Carbón Palpador. | |
| dc.subject.keyword | Ultrasonic Immersion Testing | |
| dc.subject.keyword | Search Unit | |
| dc.subject.keyword | Carbon Iron Pipe | |
| dc.subject.keyword | Lost of Thickness | |
| dc.title | Aplicación de la técnica de ultrasonido para la estimación de la perdida de espesor en la superficie externa de una pieza tubular | |
| dc.title.english | Application of ultrasound technique for estimating loss external thickness on the surface of a tubular piece | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |