Publicación: Diseño e implementación de un sistema para la medición de la reactividad pupilar a través de visión artificial
| dc.contributor.advisor | Barrero Pérez, Jaime Guillermo | |
| dc.contributor.advisor | Plata Gómez, Arturo | |
| dc.contributor.author | Avendaño Diaz, Juan Camilo | |
| dc.contributor.author | Nuñez Larrota, Fabian | |
| dc.date.accessioned | 2024-03-03T19:26:58Z | |
| dc.date.available | 2012 | |
| dc.date.available | 2024-03-03T19:26:58Z | |
| dc.date.created | 2012 | |
| dc.date.issued | 2012 | |
| dc.description.abstract | El presente proyecto es resultado del trabajo conjunto de los Grupos CEMOS (Grupo de Investigación en Control, Electrónica, Modelado y Simulación) y GOTS (Grupo de Óptica y Tratamiento de Señales) de la Universidad Industrial de Santander, con el fin de proporcionar al Grupo de Investigación en Neurociencias y Comportamiento de la misma universidad, un sistema pupilométrico, que permita iniciar investigaciones en el área de la psicofisiología. La psicofisiología estudia la relación entre la actividad fisiológica y los procesos psicológicos en humanos. Dicha actividad fisiológica se suele registrar a partir de procedimientos no invasivos, dentro de los cuales, la variación del diámetro pupilar es una de las medidas más habituales, pues existen evidencias que señalan una posible relación entre diversos aspectos comportamentales y la variación de dicho diámetro. La medición del tamaño de la pupila o su diámetro es comúnmente señalada como pupilometría e incluye el registro del diámetro pupilar como función del tiempo. En primera instancia se seleccionó e implementó un sistema para la adquisición de imágenes oculares, teniendo presente que la pupila de un ojo humano puede variar entre los 1.5 y 9 milímetros de diámetro, reaccionando ante estímulos en 0.2 segundos. Además, la cámara seleccionada para el sistema de adquisición de imágenes se caracterizó, se estableció un protocolo de medición y calibración para el sistema pupilométrico desarrollado y se implementó un algoritmo que permite, a partir de las imágenes oculares obtenidas por el sistema de adquisición, realizar la medición del tamaño pupilar en función del tiempo con una exactitud de ±0.2mm. | |
| dc.description.abstractenglish | This project is the result of collaboration between CEMOS (Research Group in Control, Electronics, Modeling and Simulation) and GOTS (Optics and Signal Processing Research Group) research groups from Universidad Industrial de Santander. It has been done in order to provide a pupillometric system to the Neuroscience and Behavior Research Group from the same university. The idea is to allow the begining of researches in the psychophysiology area. Psychophysiology studies the relationship between physiological activity and psychological processes in humans. In this area, physiological activity use to be measured using non-invasive procedures. Measuring pupil diameter changes is one of the most common procedures since there is evidence of a possible link between behavioral aspects and pupil diameter variations. Measuring pupil size or diameter is commonly named as pupillometry and includes measuring pupil diameter as a time function. First of all, there was selected and implemented an adquisition system, taking into account that pupil diameter varies from 1.5 mm up to 8 or 9 mm, reacting to stimuli in 0.2 seconds. In addition, the selected camera was characterized, there was established a measurement and calibration protocol and there was implemented an algorithm that measures pupil size through time with an ± 0.2mm accuracy. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/26528 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Pupilometría | |
| dc.subject | Visión Artificial | |
| dc.subject | Infrarrojo Cercano | |
| dc.subject | LabVIEW. | |
| dc.subject.keyword | Pupillometry | |
| dc.subject.keyword | Computer Vision | |
| dc.subject.keyword | Near Infrared | |
| dc.subject.keyword | LabVIEW. | |
| dc.title | Diseño e implementación de un sistema para la medición de la reactividad pupilar a través de visión artificial | |
| dc.title.english | Design and implementation of a system for measuring pupil reactivity using computer vision | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |