Logotipo del repositorio

Publicación:
Comparación técnica, económica y ambiental de dos trenes tecnológicos para el tratamiento de las aguas residuales de los asentamientos no planificados “Miradores de la UIS”, “El Porvenir” y “Santos Bajo” en la ciudad de Bucaramanga, Colombia.

dc.contributor.advisorDomínguez Rivera, Isabel Cristina
dc.contributor.advisorOviedo Ocaña, Edgar Ricardo
dc.contributor.authorVega Ordoñez, Aider Ferney
dc.contributor.authorMayorga Betancur, Brandon Esteban
dc.contributor.evaluatorParra Orobio, Brayan Alexis
dc.contributor.evaluatorGuarín Corredor, Tatiana
dc.date.accessioned2024-08-28T15:03:47Z
dc.date.available2024-08-28T15:03:47Z
dc.date.created0024-08-12
dc.date.issued2024-08-12
dc.description.abstractEn los asentamientos no planificados el aumento de la población y el incremento del consumo de agua generan grandes problemas con la eliminación de aguas residuales domésticas. Estas aguas, en muchos casos, se vierten directamente en áreas abiertas o en los cuerpos hídricos cercanos. Esto expone a los habitantes a riesgos de salud debido a la contaminación del agua. Es por eso que la presente investigación tuvo como objetivo comparar técnica, económica y ambientalmente dos trenes tecnológicos para el tratamiento de las aguas residuales de los asentamientos no planificados “Miradores de la UIS”, “El Porvenir” y “Santos Bajo” en la ciudad de Bucaramanga, Colombia. La metodología para la realización del proyecto se dividió en tres etapas. Primero, se caracterizaron las variables requeridas para el predimensionamiento de los trenes de tratamiento de aguas residuales en la zona de estudio; segundo, se predimensionaron las unidades que conforman los trenes de tratamiento de aguas residuales propuestos; tercero, se evaluaron los aspectos técnicos, ambientales y económicos de los trenes propuestos en el contexto de estudio. El tren uno está compuesto por: reactor UASB, filtro percolador y tanque de contacto de cloro, mientras que el tren dos está compuesto por reactor UASB, filtro anaerobio de flujo ascendente y tanque de contacto de cloro. Al comparar los aspectos técnicos se observó que el consumo energético del tren de tratamiento uno es mayor entre 0.5 a 1.5 KW/hab.año que el del tren dos. Al comparar los aspectos de afectación ambiental (malos olores, aerosoles, insectos y ruidos) se observó que tanto el tren uno como el tren dos poseen un valor medio de afectación. Al comparar los aspectos económicos se observó que los valores del Capital expenditures (CAPEX) y operating expenses or expenditure (OPEX) fueron mayores en el tren de tratamiento uno, mientras que en el caso del valor del CAPEX calculado en el proyecto fue mayor en el tren de tratamiento dos. Finalmente, el desarrollo de esta investigación aporta información valiosa para la toma de decisiones en la selección de una planta de tratamiento descentralizada para las aguas residuales domésticas de los asentamientos no planificados de la zona de estudio que contribuya a el mejoramiento en la calidad de vida de los habitantes de la zona, de igual forma en una reducción en la carga contaminante del Río Suratá.
dc.description.abstractenglishIn unplanned settlements, population growth and increased water consumption create major problems with domestic wastewater disposal. These waters, in many cases, are discharged directly into open areas or into nearby water bodies. This exposes residents to health risks due to water contamination. The present research aims to compare technically, economically and environmentally two technological trains for the treatment of wastewater from the unplanned settlements “Miradores de la UIS”, “El Porvenir” and “Santos Bajo” in the city of Bucaramanga, Colombia. Project methodology was divided into three stages. First, the variables required for the pre-sizing of the wastewater treatment trains in the study area were characterized; second, the units that make up the proposed wastewater treatment trains were pre-sized; Third, the technical, environmental and economic aspects of the proposed trains in the study context were evaluated. Train one is composed of: UASB reactor, trickling filter and chlorine contact tank, while train two is composed of UASB reactor, anaerobic filter and chlorine contact tank. When comparing the technical aspects, it was observed that the energy consumption of treatment train one is greater between 0.5 to 1.5 KW/inhabitant.year than train two. When comparing the aspects of environmental impact (bad odors, aerosols, insects and noise) it was observed that both train one and train two have an average impact value. When comparing the economic aspects, it was observed that the values of Capital expenditures (CAPEX) and operating expenses or expenditure (OPEX) were higher in treatment train one, while in the case of the CAPEX value calculated in the project was higher in treatment train two. Finally, the development of this research provides valuable information for decision-making in the selection of a decentralized treatment plant for domestic wastewater from unplanned settlements in the study area, contributing to the improvement in the life quality of the inhabitants of the area, as well as a reduction in the polluting load of the Suratá River.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Civil
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/43947
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programIngeniería Civil
dc.publisher.schoolEscuela de Ingenieria Civil
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjecttratamiento
dc.subjectaguas residuales
dc.subjectasentamientos no planificados
dc.subjecteconómico
dc.subjecttécnico
dc.subjectambiental
dc.subject.keywordwastewater
dc.subject.keywordtreatment
dc.subject.keywordunplanned settlements
dc.subject.keywordeconomical
dc.subject.keywordtechnical
dc.subject.keywordenvironmental
dc.titleComparación técnica, económica y ambiental de dos trenes tecnológicos para el tratamiento de las aguas residuales de los asentamientos no planificados “Miradores de la UIS”, “El Porvenir” y “Santos Bajo” en la ciudad de Bucaramanga, Colombia.
dc.title.englishTechnical, economic and environmental comparison of two wastewater treatment for the unplanned settlements “Miradores de la UIS”, “El Porvenir” and “Santos Bajo” in the city of Bucaramanga, Colombia.
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
105.65 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
28.97 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
380.1 KB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
2.18 KB
Formato:
Item-specific license agreed to upon submission
Descripción:

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031