Logotipo del repositorio

Publicación:
Análisis económico comparativo de sistemas de calefacción de agua en edificaciones con distribución centralizada o particular

dc.contributor.advisorGarcía Solano, Mario
dc.contributor.authorViviescas Vargas, Néstor Alirio
dc.contributor.authorMoreno López, Daniel Hernando
dc.date.accessioned2024-03-03T20:07:10Z
dc.date.available2013
dc.date.available2024-03-03T20:07:10Z
dc.date.created2013
dc.date.issued2013
dc.description.abstractEl documento muestra los resultados, observaciones y conclusiones del análisis hecho a sistemas de calentamiento de agua con distribución central o particular en edificaciones de uso residencial, mediante la comparación tanto de funcionalidad como del costo en cada caso. Dicha comparación se hizo tomando como base del estudio un diseño hidráulico real para un sistema de calentamiento y distribución centralizada de agua, en una edificación tipo residencial de 21 pisos y 58 apartamentos, permitiendo generar un diseño paralelo con especificaciones similares pero con la implementación de calentadores individuales por apartamento a fin de poder ejecutar una adecuada comparación entre los dos sistemas descritos. En tramos rectos de montantes aunque aumentan los diámetros de tubería ya que lo hacen proporcionalmente al caudal; la reducción del costo se manifiesta es en la disminución de longitud de los mismos debido a que se excluye la impulsión de agua caliente desde la parte inferior de la edificación; consecuente con esto se evitan los costos por medidores, la caldera central y el sistema de recirculación ubicado en la parte superior del edificio. El hecho de manejar solo la impulsión de agua fría evita la utilización del sin número de válvulas reductoras de presión ubicadas a lo largo de la montante de agua caliente, existente en el diseño original de calefacción central lo que también beneficia económicamente el diseño individual propuesto. Como sobrecosto al sistema que se desarrolla en la propuesta de grado (sistema de calefacción individual por apartamentos) podemos encontrar la implementación de calentadores en cada uno de los inmuebles, lo que se compensaría de una u otra forma con alguna de las especificaciones del sistema centralizado; con la salvedad de representar un costo inferior al encontrado en el sistema base de caldera central.
dc.description.abstractenglishThe paper shows the results, findings and conclusións of the analysis made water heating systems with central distribution or particularly residential buildings, by comparing both the functionality and the cost in each case. This comparison is made based on the actual hydraulic design study for a heating system and centralized distribution of water in a residential building of 21 floors and 58 apartments, allowing to generate a parallel with similar specs but with the implementation of heaters individual apartment in order to run a proper comparison between the two systems described. In straight sections of uprights although increasing pipe diameters since they do proportion to flow, the cost reduction is manifested in decreasing length thereof is excluded because the hot water discharge from the bottom of the construction, consistent with this costs are avoided by measuring the central boiler and the recirculation system located on top of the building. The fact drive handle only cold water avoids the use of any number of pressure-reducing valves located along the upright of hot water, existing in the original design of heating which also benefits economically individual design proposed. As the system overhead which is developed in the proposed degree (heating system per apartment) we find heaters implementing each of the properties, which would be offset in one or another way with any of the centralized system specifications, with the exception of representing a lower cost than found in the central boiler-based system.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Civil
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/29104
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programIngeniería Civil
dc.publisher.schoolEscuela de Ingeniería Civil
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectAcometida
dc.subjectMontante
dc.subjectHidroneumático
dc.subjectPerdidas
dc.subjectVálvulas.
dc.subject.keywordConnection
dc.subject.keywordUpright
dc.subject.keywordHydro Pneumatic
dc.subject.keywordLost
dc.subject.keywordValves.
dc.titleAnálisis económico comparativo de sistemas de calefacción de agua en edificaciones con distribución centralizada o particular
dc.title.englishComparative ecomomic analysis of water heating systems for buildings with centralized or paticular distribution
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
5.89 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
540.8 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031