Logotipo del repositorio

Publicación:
Desarrollo de un sistema mediante turbidimetría para la evaluación de formación de haze a diferentes temperaturas

dc.contributor.advisorMaradei García, María Paola
dc.contributor.advisorMendoza Flórez, Liliana Cristina
dc.contributor.authorPedraza Parra, Camila Andrea
dc.date.accessioned2024-03-03T20:35:24Z
dc.date.available2014
dc.date.available2024-03-03T20:35:24Z
dc.date.created2014
dc.date.issued2014
dc.description.abstractLa presencia de precipitados insolubles (haze) en el biodiesel de aceite de palma ocasiona el taponamiento de filtros e inyectores en motores, por tal razón, es necesario indagar sobre métodos para su cuantificación. La turbidimetría puede ser utilizada para determinar la concentración de haze, puesto que, el análisis turbidimétrico mide la disminución de la intensidad de los rayos incidentes causada por la dispersión de partículas presentes. Por lo tanto, la variación de la señal de turbidimetría puede ser asociada a una variación en la concentración de material particulado suspendidos en un líquido. En este trabajo se desarrolla una unidad piloto para cuantificar el haze en el biodiesel usando turbidimetría. Se encontraron las mejores condiciones de agitación y altura de la sonda para medir la concentración de precipitados de manera reproducible, sin alteraciones en la señal por presencia de vortex y/o burbujas dentro de la matriz. En esas condiciones, se construyó una curva de calibración para relacionar la señal de turbidez con la concentración de haze (0 170 mg/L). La curva fue probada a diferentes temperaturas y por análisis estadístico se encontró que la señal de turbidez no es afectada con esta variable. Para la validación del sistema se aplicaron las pruebas D7501 y D7321 a dos lotes de biodiesel comercial provenientes de Ecoflores y conteniendo respectivamente, 157,7 y 104,3 mg/L. Se encontró que la cantidad de haze predicha por la curva de calibración es inferior al obtenido por la norma D7321, siendo la diferencia entre ellas más importante para mayores concentraciones de haze. La subestimación de la concentración de material particulado obtenida por turbidimetría se explica por la existencia de problemas de sedimentación en el sistema, los cuales son más importantes cuando la concentración de material particulado es superior a 100mg/L.
dc.description.abstractenglishThe insoluble precipitates (haze) in palm oil biodiesel cause the plugging of filters and injectors in motors; therefore, it is necessary to inquire methods for haze quantification. Turbidimetry can be used to determinate haze concentration because turbidimetric analysis measures the diminution of intensity of incident rays, caused by the dispersion of present particles. Thus, variation in the turbidimetric signal can be associated with a variation in the concentration of particulate material suspended in a liquid. In this job a system is developed to quantify the haze in the biodiesel using turbidimetry. . The best conditions for mixing and high of the turbidimetry probe were found to measure the concentration of precipitated reproducibly. Inside of the organic matrix was no presence of vortex and/or bubbles that affect turbidity signal. A calibration curve was constructed under these conditions, the turbidity signal was related to haze concentration (0-170 mg / L). The curve was tested at different temperatures and a statistical analysis found that the turbidity signal is not affected by this variable. To validate the system were applied the D7501 and D7321 tests to two lots of commercial biodiesel. The biodiesel from Ecoflores. The haze was found 157.7 and 104.3 mg / L, respectively. It was found that predicted quantity of haze using the adjusted model to the equation of the calibration curve is lower than the obtained by the D7321 test, being more significant the difference at higher concentrations of particulate material. The underestimation of the concentration of precipitates obtained by turbidimetry could mean the existence of sedimentation problems in the system, which are more important when particulate material is over 100mg/L.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/29797
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectBiodiesel
dc.subjectPrecipitados
dc.subjectHaze
dc.subjectTurbidimetría
dc.subjectSedimentación
dc.subject.keywordBiodiesel
dc.subject.keywordTurbidimetry
dc.subject.keywordHaze
dc.subject.keywordSedimentation.
dc.titleDesarrollo de un sistema mediante turbidimetría para la evaluación de formación de haze a diferentes temperaturas
dc.title.englishDevelopment of a system by turbidimetry to monitoring haze in palm biodiesel to different temperature
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
208.8 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
1.96 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
231.46 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031