Publicación: Controladores robustos gft para la regulación automática del nivel de glucosa en pacientes con diabetes mellitus tipo i: diseño y validación numérica
| dc.contributor.advisor | Villamizar Mejía, Rodolfo | |
| dc.contributor.author | Monsalve Monsalve, Reynel | |
| dc.contributor.author | Vecino Duran, Claudia Juliana | |
| dc.date.accessioned | 2024-03-03T18:42:49Z | |
| dc.date.available | 2011 | |
| dc.date.available | 2024-03-03T18:42:49Z | |
| dc.date.created | 2011 | |
| dc.date.issued | 2011 | |
| dc.description.abstract | Este articulo presenta los resultados numéricos de la validación de controladores robustos para la regulación automática del nivel de glucosa en la sangre en pacientes con Diabetes Mellitus Tipo 1 (DMT1), usando para su diseño el modelo de un sensor continuo de glucosa y una bomba infusora de insulina y versiones reducidas del modelo numérico no lineal de Sorensen, obtenidas a partir de la linealización del modelo con la herramienta ldent de Matlab seleccionando las funciones de transferencia que presentaban un mejor ajuste. Para obtener los controladores robustos se considero la técnica Quantitative Feedback Theory (QFT), cuyo principal objetivo es el diseño de controladores de mínimo ancho de banda que satisfagan todas las especificaciones de comportamiento deseadas contemplando incertidumbre paramétrica en la planta del sistema. Se generaron plantillas según las frecuencias de trabajo seleccionadas y se obtuvieron los contornos de comportamiento según restricciones de seguimiento y reducción de la sensibilidad, se añadieron polos y ceros a la función de lazo abierto hasta obtener los controladores para periodos de muestreo de 1, 5 y 10 minutos. Los resultados se validaron numéricamente sobre el modelo no lineal de Sorensen ante una perturbación caracterizada por simular la dieta de un paciente diabético en un día. Se evaluó el desempeño de los controladores diseñados según el criterio de la integral del error IAE e ITAE teniendo como conclusión que los controladores diseñados para 5 y 10 minutos presentan un menor tiempo de establecimiento y una respuesta más rápida ante la perturbación. | |
| dc.description.abstractenglish | This paper presents the numerical validation of robust controllers for the automatic regulation of blood glucose level in patients with Type 1 Diabetes Mellitus (T1MD). The controllers were designed using the model of a continuous glucose sensor and an insulin pump, and a scaled-down version of the nonlinear numerical Sorensen model. A system identification tool was used to calculate a set of transfer functions, selecting the ones which fitted better. The Quantitative Feedback Theory (QFT) technique was used to tune the controllers. This technique is based in the objective of designing a controller, with lowest bandwidth, which meets all the performance specifications and considers parametric uncertainty in the system. Templates were generated according to selected working frequencies and contours were obtained as restrictions of monitoring behavior and reduced sensitivity. Poles and zeros were added to the open-loop function to achieve a discrete controller at periods of 1, 5 and 10 minutes. Results were numerically validated against the nonlinear Sorensen model to simulate a disturbance characterized by the daily diet of a diabetic patient. The performance of the controllers designed at the discretion of the error integral IAE and ITAE taking the conclusion that drivers designed for 5 to 10 minutes have a lower settling time and a faster response to disturbance. 3 Final | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/25522 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Bounds | |
| dc.subject | Controlador QFT | |
| dc.subject | Diabetes | |
| dc.subject | Glucosa | |
| dc.subject | Incertidumbre paramétrica | |
| dc.subject | Insulina | |
| dc.subject | Templates | |
| dc.subject.keyword | Bounds | |
| dc.subject.keyword | Diabetes | |
| dc.subject.keyword | Glucose | |
| dc.subject.keyword | Insulin | |
| dc.subject.keyword | Parametric Uncertainty | |
| dc.subject.keyword | QFT controllers | |
| dc.subject.keyword | Templates | |
| dc.title | Controladores robustos gft para la regulación automática del nivel de glucosa en pacientes con diabetes mellitus tipo i: diseño y validación numérica | |
| dc.title.english | Qft robust controllers for automatic regulation of glucose in patients with diabetes mellitus type |: design and numerical | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 177.09 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 584.95 KB
- Formato:
- Adobe Portable Document Format