Publicación: Estudio experimental de la resistencia a la corrosión de un acero al carbono aisi sae 1020 implantado con iones de titanio vía plasma
| dc.contributor.advisor | Peña Ballesteros, Darío Yesid | |
| dc.contributor.advisor | Valbuena Niño, Ely Dannier | |
| dc.contributor.author | Reyes Corzo, Martha Sofia | |
| dc.date.accessioned | 2024-03-03T18:48:31Z | |
| dc.date.available | 2011 | |
| dc.date.available | 2024-03-03T18:48:31Z | |
| dc.date.created | 2011 | |
| dc.date.issued | 2011 | |
| dc.description.abstract | El método 3DII (Three-Dimensional Ion Implantation), de modificación superficial, está basado en una descarga pulsada de alto voltaje a bajas presiones. Los pioneros en el estudio de este tipo de descarga fueron Klarfeld, Pokrovskaya-Soboleva y McClure. En la UIS, el grupo FITEK ha implementado éste método a escala semindustrial; los grupos GOTS, LEAM de la Escuela de Física y el Laboratorio de Difracción de Rayos X estudian en conjunto las condiciones físicas de las superficies implantadas; así mismo el Grupo GIC de la Escuela de Ingeniería Metalúrgica y Ciencia de Materiales y la Corporación para la Investigación de la Corrosión (CIC) analizan el efecto de éste método para contrarrestar el fenómeno de la corrosión en aceros y aleaciones. Esta investigación evalúa el comportamiento frente a la corrosión en la superficie de cupones de acero AISI SAE 1020, sin tratamiento y modificados con iones de titanio, a energías de 5 y 10 keV y tiempos de exposición a la dosis de implantación de 6 y 12 minutos, sumergidos de 0 a 28 días en solución electrolítica de NaCl al 3%, utilizando pruebas de inspección visual, microscopía óptica y técnicas electroquímicas como: OCP, Rp, Extrapolación de Tafel y EIS. Los resultados indican que los cupones con menor velocidad de corrosión fueron implantados con 5 k eV y un tiempo de 12 minutos, siendo inferiores en un 85% respecto a los cupones sin tratamiento superficial después de 28 días en la solución. Los cupones implantados a 5 keV respecto a los de 10 keV mostraron mejores condiciones, deduciendo mayor estabilidad del pulso de descarga durante el proceso de implantación para los primeros. Se concluye que esta tecnología de tratamiento superficial es un mecanismo efectivo para mitigar el efecto de la corrosión en aceros de bajo contenido de carbono y baja aleación expuestos a medios agresivos. | |
| dc.description.abstractenglish | The method of superficial modification 3DII (Three-dimensional Ion Implantation), it is based on a pressed discharge of high voltage to drops pressures. The pioneers in the study of this discharge type were Klarfeld, Pokrovskaya-Soboleva and McClure. In the UIS, the group FITEK has implemented this method to semindustrial scale; in associate with the groups GOTS, LEAM of the Physics School and the Diffraction X Rays Laboratory they study the physical conditions of the implanted surfaces; likewise the GIC research group of the Metallurgical and Science Materials Engineering School and the Corporation for the Investigation of the Corrosion (CIC) they analyze the effect of this method to counteract the corrosion phenomenon in steels and alloys. This investigation evaluates the behavior front corrosion in the surface AISI SAE 1020 steel coupons without treatment and modified with titanium ions at energy of 5 and 10 keV and times of exhibition to the dose of installation of 6 and 12 minutes, submerged of 0 to 28 days in electrolytic solution of NaCl at the 3%, using tests of visual inspection, optic microscopy and electrochemical techniques as: OCP, Rp, Extrapolation of Tafel and EIS. The results indicate that the coupons with smaller speed of corrosion were implanted with 5 keV and a time of 12 minutes, being inferior in 85% regarding the coupons without superficial treatment after 28 days in the solution. The implanted coupons to 5 keV regarding those of 10 keV showed better conditions, deducing bigger stability of the discharge pulse during the trial from installation for the first ones. You conclude that this superficial technology treatment is effective mechanism to mitigate the effect of the corrosion in low carbon steels content and low alloy exposed to aggressive means. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Metalúrgico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/26135 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Metalúrgica | |
| dc.publisher.school | Escuela de Ingeniería Metalúrgica y Ciencia de Materiales | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Acero AISI SAE 1020 | |
| dc.subject | Implantación Iónica | |
| dc.subject | Modificación superficial | |
| dc.subject | Iones de titanio | |
| dc.subject | Corrosión | |
| dc.subject | Técnicas Electroquímicas | |
| dc.subject | Inspección Topográfica. | |
| dc.subject.keyword | AISI SAE 1020 Steel | |
| dc.subject.keyword | Ionic Implantation | |
| dc.subject.keyword | Surface Modification | |
| dc.subject.keyword | Titanium Ions | |
| dc.subject.keyword | Corrosion | |
| dc.subject.keyword | Electrochemical Techniques | |
| dc.subject.keyword | Topography Inspection. | |
| dc.title | Estudio experimental de la resistencia a la corrosión de un acero al carbono aisi sae 1020 implantado con iones de titanio vía plasma | |
| dc.title.english | Experimental study of the corrosion resistance of aisi sae 1020 carbon steel implanted with titanium ions to plasma inmersion. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 69.91 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Documento.pdf
- Tamaño:
- 11.64 MB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 345.2 KB
- Formato:
- Adobe Portable Document Format