Publicación: Relación entre la resistencia a la compresión, porosidad y velocidad de pulso ultrasónico en el concreto variando la relación agua/cemento
| dc.contributor.advisor | Quintero Ortiz, Luz Amparo | |
| dc.contributor.advisor | Herrera Ortiz, Julian Orlando | |
| dc.contributor.author | Corzo Patino, Laura Angelica | |
| dc.contributor.author | Garcia Duarte, Johanna Ximena | |
| dc.date.accessioned | 2024-03-03T17:32:36Z | |
| dc.date.available | 2009 | |
| dc.date.available | 2024-03-03T17:32:36Z | |
| dc.date.created | 2009 | |
| dc.date.issued | 2009 | |
| dc.description.abstract | Este trabajo presenta la influencia de la porosidad sobre la resistencia a la compresión del concreto y la velocidad de pulso ultrasónico, esto es evaluado en probetas de concreto fabricadas con cemento Portland tipo I, con relaciones agua/cemento de 0.45; 0.50; 0.55 y 0.60; ensayados en los días 7, 14 y 28 de curado; el cual fue realizado al medio ambiente bajo techo. Se establecieron las relaciones correspondientes entre las variables estudiadas. El desarrollo de esta investigación se hace con el fin de estudiar el comportamiento de la velocidad de pulso ultrasónico en el concreto, el cual es uno de los materiales más utilizados por el hombre y uno de los más expuestos a daños producidos por el medio ambiente. Un factor influyente en el concreto es la porosidad, afectando su resistencia a la compresión, permitiendo el ingreso de agentes agresivos y en general disminuye el tiempo de vida útil proyectado para la estructura. Estudios anteriores han mostrado que la porosidad depende de la relación agua/cemento (a/c) empleada en la mezcla. Uno de los métodos para evaluar las estructuras sin afectarlas es el ultrasonido, por medio de este se puede estimar la resistencia mecánica tanto in situ como en laboratorio. La técnica ultrasónica de mayor aplicación es la de velocidad de pulso ultrasónico (VPU) la cual se basa en la medición del tiempo de vuelo del haz sonoro, pudiéndose relacionar con la resistencia a la compresión del concreto. Los resultados de este estudio están dirigidos a evaluar la posibilidad de la aplicación de la técnica de VPU en la evaluación de concreto a edad temprana. | |
| dc.description.abstractenglish | This work explains the porosity influence on the concrete™s compression resistance and the pulse ultrasonic velocity. This influence is evaluated in test tubes made of concrete with Cement Portland type I, with a water/cement ratio of 0.45; 0.50; 0.55 and 0.60. The experiments were carried out at 7, 14 and 28 days of curing at room conditions under roof. Correlations between the studied variables were established. This research was developed with the purpose of analyze the pulse ultrasonic velocity behavior in concrete, which is one of the most used materials by men, and one of the most exposed to damage caused by the environment. Porosity has a big influence on concrete as it affects its compression resistance allowing aggressive agents to be incorporated into the concrete matrix, and causing a decreasing on the structure lifespan. Previous studies have proved that porosity strongly depends on the water/cement ratio (a/c) used for the mix. One of the methodologies to evaluate structures without affecting them is by using ultrasounds, which allows estimating in situ and lab mechanic resistance. The most used ultrasonic technique is the pulse ultrasonic velocity (PUV), which is based on the sound beam fly time measurement and its relationship to the concrete™s resistance compression. The purpose of this study is to evaluate the application of the PUV technique for the assessment of concrete at early age. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Metalúrgico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/22331 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Metalúrgica | |
| dc.publisher.school | Escuela de Ingeniería Metalúrgica y Ciencia de Materiales | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Concreto | |
| dc.subject | Resistencia a la Compresión | |
| dc.subject | Porosidad | |
| dc.subject | Velocidad de Pulso Ultrasónico. | |
| dc.subject.keyword | Concrete | |
| dc.subject.keyword | Compression Resistance | |
| dc.subject.keyword | Porosity | |
| dc.subject.keyword | Pulse Ultrasonic Velocity | |
| dc.title | Relación entre la resistencia a la compresión, porosidad y velocidad de pulso ultrasónico en el concreto variando la relación agua/cemento | |
| dc.title.english | Relation between compression strength, porosity and pulse ultrasonic velocity in concrete varying the water / cement ratio | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 1.6 MB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 382.61 KB
- Formato:
- Adobe Portable Document Format