Logotipo del repositorio

Publicación:
Evaluación de la sinergia entre el microdesgaste y la corrosión de recubrimiento de ácido poliglicoli-co-copolimero en contacto con hueso y fluido sinovial

dc.contributor.advisorPeña Ballesteros, Darío Yesid
dc.contributor.authorInfante Villalba, Sergio Andrés
dc.contributor.authorRamírez Parada, Laura Andrea
dc.date.accessioned2024-03-03T18:04:41Z
dc.date.available2010
dc.date.available2024-03-03T18:04:41Z
dc.date.created2010
dc.date.issued2010
dc.description.abstractDebido a las características del sistema inmunológico, cuando se introduce un cuerpo extraño en el organismo, éste tiende a rechazarlo o inclusive a atacarlo, generando una serie de síntomas posibles entre estas inflamaciones, malformaciones, dolores, fiebre, etc., que pueden obligar a retirar la prótesis colocada. Los rechazos pueden minimizarse si se selecciona adecuadamente el material a ser usado, de tal forma que sea atóxico e inerte, para alterar lo menos posible el medio donde se coloca el implante.[1] A lo largo de las extensas aplicaciones de los polímeros, la tribología de los polímeros ha tenido cada vez más importancia. El progreso en la comprensión sobre este campo en la última década, es analizada en virtud de los diferentes temas que existen para la tribología, entre ellos la tribología de materiales poliméricos.[2] En este trabajo se evaluará el sinergismo entre el desgaste y la corrosión, en unas probetas de titanio sin recubrimiento y recubiertas por PLGA. Los ensayos se realizaron en una máquina de tribocorrosión, teniendo en cuenta dos variables: velocidad de rayado y carga aplicada. Se adecuó un bipotencióstato para obtener las curvas Tafel, Potenciostáticas e EIS en condiciones de reposo, en movimiento y desgaste-corrosión. Adicionalmente se realizó un estudio de fricción de superficies. La topografía de superficies se realizó usando un microscopio Imager Z1 de Carl-Zeiss. Esta información, conjuntamente con los resultados de pérdida de masa y de los ensayos electroquímicos, se usó para establecer los mecanismos sinergísticos y de degradación del material en las diferentes condiciones de ensayo. De los resultados obtenidos en este trabajo, se observó que el sinergismo es el factor importante de la degradación en la superficie recubierta con un porcentaje de 82 %, siendo el proceso fundamental de remoción del material que se concluye como desgaste puro.
dc.description.abstractenglishDue to the nature of the immune system, when introducing a foreign organism in the body, it tends to reject it or even to attack, generating a series of possible symptoms, among them, swelling, deformities, pain and fever. This may require removing the prosthesis. The rejections can be minimized by properly selecting the material to be used in such a way that is non-toxic and inert, to alter as little as possible the environment where the implant is placed. Throughout the extensive applications of polymers, understanding the tribology of polymers has become increasingly important. Progress in understanding this field in the last decade is reviewed under different topics that exist for tribology, including the tribology of polymer materials. In this paper, the synergism between wear and corrosion will be evaluated in some uncoated titanium specimens and coated with PLGA. The tests were performed on a tribocorrosion machine taking into account two variables, scratch speed and applied load. It adapts a bipotenciostat for Tafel curves, Potentiostatic and EIS at rest, in motion and wear-corrosion. Additionally, a study of friction surfaces was performed. The surface topography was performed using an Imager Z1 microscope Carl-Zeiss. This information, together with the results of mass loss and electrochemical tests, was used to establish the synergistic mechanisms and material degradation in the different test conditions. From the results obtained in this study, it was found that the synergism is the most important process of degradation in the coated surface, with a percentage of 82%, and the fundamental process of material removal, which was concluded as pure wear.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Metalúrgico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/23278
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Metalúrgica
dc.publisher.schoolEscuela de Ingeniería Metalúrgica y Ciencia de Materiales
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectTribocorrosión
dc.subjectSinergismo desgaste-corrosión
dc.subjectCorrosión acelerada por desgaste
dc.subjectDesgaste acelerado por corrosión
dc.subjectTitanio
dc.subjectbiopolímeros degradables
dc.subjectdesgaste.
dc.subject.keywordTribocorrosion
dc.subject.keywordWear-corrosion synergism
dc.subject.keywordWear-accelerated corrosion
dc.subject.keywordCorrosion- accelerated wear
dc.subject.keywordTitanium
dc.subject.keywordbiodegradable biopolymers
dc.subject.keywordwear.
dc.titleEvaluación de la sinergia entre el microdesgaste y la corrosión de recubrimiento de ácido poliglicoli-co-copolimero en contacto con hueso y fluido sinovial
dc.title.englishAssessment of the synergy between microwear and polyglycolic acidcopolymer coating corrosion in contact with bone and synovial fluid
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
946.47 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
3.14 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
321.86 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031