Publicación: Medidor de impedancia electroquimica
| dc.contributor.advisor | Barrero Perez, Jaime Guillermo | |
| dc.contributor.advisor | Amaya Palacio, Jose Alejandro | |
| dc.contributor.author | Rodriguez Pacheco, Jorge Humberto | |
| dc.contributor.author | Ruiz Gomez, Sergio Andres | |
| dc.date.accessioned | 2024-03-03T04:40:06Z | |
| dc.date.available | 2004 | |
| dc.date.available | 2024-03-03T04:40:06Z | |
| dc.date.created | 2004 | |
| dc.date.issued | 2004 | |
| dc.description.abstract | Este trabajo describe las características principales del diseño y construcción de un equipo Medidor de Impedancia Electroquímica (MIE), para pruebas de Impedancia en el laboratorio de corrosión de la Escuela de Ingeniería Metalúrgica y Ciencia de Materiales. El medidor de impedancia electroquímica es un prototipo autónomo que permite la realización de pruebas de laboratorio. Realiza un barrido de frecuencia comprendido entre 130mHz y 62kHz (6 décadas) con la posibilidad de escoger entre 2, 4, 6 u 8 valores de frecuencia por década. Entrega a la celda una tensión senoidal de amplitud constante durante toda la prueba de 50mVp-p, 35mVp-p o 20mVp-p según la configuración dada por el usuario. El control general del prototipo es realizado por un microcontrolador PIC16F877, el cual se encarga del control del barrido de frecuencia, de la ganancia variable del amplificador medidor de corriente, de la medición de fase y frecuencia mediante temporizadores, conversión A/D de la amplitud pico de la corriente y de la fase por hardware, del almacenamiento de los datos medidos, comunicación con el PC mediante puerto paralelo y con el PIC16F84A encargado de la interfaz con el usuario mediante pulsadores y una pantalla LCD. La visualización de resultados se realiza en el PC con una aplicación implementada mediante Labview, en la cual se realizan las gráficas de Bode (magnitud, fase por hardware y fase medida por el PIC) y Nyquist, se registran los valores de corriente, magnitud de la impedancia, impedancia real e imaginaria y fase para cada valor de frecuencia evaluado y se determinan los valores de resistencia Rs, Rp y condensador CD equivalente de un sistema electroquímico simple según la celda de | |
| dc.description.abstractenglish | This work describes the main characteristics of the design and construction of a team Meter of Electrochemical Impedance (MIE), for tests of Impedance in the laboratory of corrosion of the School of Engineering Metallurgy and Science of Materials. The meter of electrochemical impedance is an autonomous prototype that allows the realization of laboratory tests. It carries out a sweeping of frequency understood between 130mHz and 62kHz (6 decades) with the possibility of choosing among 2, 4, 6 or 8 values of frequency per decade. It gives to the cell a tension senoidal of constant width during the whole test of 50mVp-p, 35mVp-p or 20mVp-p according to the configuration given by the user. The general control of the prototype is carried out by a microcontroller PIC16F877, which takes charge of the control of the sweeping of frequency, of the variable gain of the amplifier current meter, of the phase mensuration and frequency by means of timing device, converter A/D of the amplitude pick of the current and of the phase for hardware, of the storage of the measured data, communication with the PC by means of parallel port and with the PIC16F84A in charge of the interfaz with the user by means of pulsadores and a screen LCD. The visualization of results is carried out in the PC with an application implemented by means of Labview, in which the prototype are carried out the graphs of Bode (magnitude, phase for hardware and phase measured by the PIC) and Nyquist, registers the current values, magnitude of the impedance, real and imaginary impedance and phase for each evaluated value of frequency and the resistance values Rs, Rp and condenser equivalent CD of a simple electrochemical system is determined according to the cell of | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/16563 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Impedancia Barrido De Frecuencia Microcontrolador | |
| dc.subject.keyword | Impedance Sweeping Of Frequency Microcontroller | |
| dc.title | Medidor de impedancia electroquimica | |
| dc.title.english | Meter of electrochemical impedance | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |