Publicación: Evaluación, diseño y estimación de indicador de vida útil remanente de los transformadores de potencia de una Central Térmica
| dc.contributor.advisor | Quiroga Méndez, Jabid Eduardo | |
| dc.contributor.author | Luna Espitia, Juan Pablo | |
| dc.contributor.evaluator | Pinto Hernández, William | |
| dc.contributor.evaluator | González Estrada, Gonzalo Andrés | |
| dc.date.accessioned | 2025-12-10T18:26:20Z | |
| dc.date.available | 2025-12-10T18:26:20Z | |
| dc.date.created | 2025-11-18 | |
| dc.date.issued | 2025-11-18 | |
| dc.description.abstract | Los transformadores de potencia son equipos críticos en la cadena de generación de energía eléctrica y su indisponibilidad impacta de forma directa la confiabilidad y el balance económico de cualquier central térmica. Esta investigación formula un Indicador de Vida Útil Remanente (IVUR) que integra información dieléctrica, fisicoquímica, cromatografía de gases y operativa con técnicas de inteligencia artificial, a fin de priorizar el mantenimiento y prevenir fallas catastróficas. Se analizaron 4680 registros históricos (2012-2024) correspondientes a nueve transformadores con 20 variables: rigidez dieléctrica, humedad, número ácido, densidad relativa, tensión interfacial, factor de potencia, índice de calidad del aceite, nueve gases de falla clave, concentración de furanos, grado de polimerización, carga y temperatura. Tras un estudio de relevancia, se descartaron edad cronológica y pruebas eléctricas de rutina, estado físico, historial de fallas y ubicación geográfica, enfocándose en los factores que explican > 85 % de la varianza. El IVUR se estimó mediante dos enfoques: o Red Neuronal Artificial (ANN) feed forward con algoritmo Levenberg Marquardt. o Sistema Neuro Difuso Adaptativo (ANFIS) con 20 funciones de membresía gaussiana y entrenamiento híbrido. Ambos modelos se entrenaron con un reparto 70-15-15 y mostraron alta precisión (MSE ≤ 8,5 × 10⁻³; R ≥ 0,85 en prueba). La comparación con los valores de laboratorio basados en la curva de Doble para furanos arrojó errores relativos < 2 % en los nueve equipos, confirmando la validez del IVUR. El transformador TX08 resultó ser el más crítico, con IVUR ≈ 76 %, lo que respalda decisiones de intervención prioritaria. El estudio demuestra que la combinación de ANN y ANFIS supera la subjetividad de los métodos ponderados tradicionales, brinda interpretabilidad suficiente y reduce el riesgo operativo. Se recomienda implementar monitoreo en línea y validación cruzada continua para refinar el índice y soportar la toma de decisiones de la gerencia de activos. | |
| dc.description.abstractenglish | Power transformers are critical assets in the electricity generation chain, and their unavailability directly impacts the reliability and economic balance of any thermal power plant. This work proposes a Remaining Useful Life Indicator (RULI) that blends dielectric, physicochemical, gas in oil and operating data with artificial intelligence methods to support maintenance prioritization and failure prevention. A database of 4,914 historical samples (2012-2024) from nine transformers was compiled, comprising 20 variables: dielectric strength, moisture, acid number, relative density, interfacial tension, power factor, oil quality index, nine key fault gases, furan concentration, degree of polymerization, load, and temperature. Feature relevance analysis discarded chronological age and routine electrical testing, physical condition, failure history, and geographic location, focusing on factors explaining more than 85 % of variance. RULI was computed using two approaches: o A Feed forward Artificial Neural Network trained with the Levenberg Marquardt algorithm. o An Adaptive Neuro Fuzzy Inference System employing 20 Gaussian membership functions and a hybrid learning scheme. With a 70-15-15 train validation test split, both models achieved high accuracy (MSE ≤ 8.5 × 10⁻³; R ≥ 0.85 on test data). Comparison with laboratory estimates based on Duval’s furan curve showed relative errors below 2 % across all units, confirming the robustness of the indicator. Transformer TX08 emerged as the most critical asset, with a RULI of approximately 76 %, guiding priority maintenance actions. The study evidences that combining ANN and ANFIS surpasses the subjectivity of weighted sum methods, offering adequate interpretability and mitigating operational risk. Future work should include on line sensor integration and continuous cross validation to enhance indicator fidelity and asset management decision making. | |
| dc.description.degreelevel | Maestría | |
| dc.description.degreename | Magíster en Gerencia de Mantenimiento | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/46839 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
| dc.publisher.program | Maestría en Gerencia de Mantenimiento | |
| dc.publisher.school | Escuela de Ingeniería Mecánica | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Transformadores de potencia | |
| dc.subject | ANN | |
| dc.subject | ANFIS | |
| dc.subject | Furanos | |
| dc.subject | Vida útil remanente | |
| dc.subject.keyword | Power transformers | |
| dc.subject.keyword | remaining useful life | |
| dc.subject.keyword | ANN | |
| dc.subject.keyword | ANFIS | |
| dc.subject.keyword | Furan analysis | |
| dc.title | Evaluación, diseño y estimación de indicador de vida útil remanente de los transformadores de potencia de una Central Térmica | |
| dc.title.english | Evaluation, design and estimation of a remaining useful life indicator for power transformers in a thermal power plant | |
| dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Maestría | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 5 de 5
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 252.12 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 47.81 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Anexo Datos Transformadores.pdf
- Tamaño:
- 156.61 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: