Publicación: Software para la caracterización y análisis estadístico de la señal electrooculografica, usado en la determinación de asociación entre alteración de movimientos oculares sacádicos y esquizofrenia
| dc.contributor.advisor | Mendoza Castellanos, Alfonso | |
| dc.contributor.advisor | Pinzon Amado, Alexander | |
| dc.contributor.author | Blanco Diaz, Mónica Janeth | |
| dc.contributor.author | Leon Martinez, Nelson Enrique | |
| dc.date.accessioned | 2024-03-03T16:08:52Z | |
| dc.date.available | 2006 | |
| dc.date.available | 2024-03-03T16:08:52Z | |
| dc.date.created | 2006 | |
| dc.date.issued | 2006 | |
| dc.description.abstract | El presente trabajo estuvo constituido de dos partes. La primera parte fue el diseño e implementación de una herramienta software para el filtrado, la caracterización y el análisis estadístico de señales electrooculográficas. La segunda parte corresponde a la aplicación de la herramienta software en un estudio de Casos y Controles en pacientes esquizofrénicos, en el cual se exploró la posible asociación entre la alteración de los movimientos oculares sacádicos y la esquizofrenia. Fueron incluidos en el estudio 50 pacientes con diagnóstico clínico de esquizofrenia y 50 controles sanos. Fueron tomados tres tipos diferentes de medidas para todos los participantes: una entrevista psiquiátrica estructurada, una detallada evaluación optométrica y un electrooculograma. Para el filtrado de las señales, se implementaron algoritmos que hacían uso de la transformada de Wavelet y el diseño de filtros paso bajo a través del algoritmo de Parks-McClellan. La caracterización de la señal electrooculográfica permitió la detección de las regiones en las cuales se registraban movimientos sacádicos. Para cada una de las regiones o sacadas que fueron identificadas se hallaron valores para los parámetros: Amplitud, Duración, Gain, Latencia y Velocidad Pico. Con estos valores se realizó un análisis estadístico de variación utilizando el método parámetrico ANOVA de una vía o el método no parámetrico de Kruscal-Wallis cuando los datos no tenían una distribución normal. El análisis estadístico del estudio mostró que no habían diferencias estadísticamente significativas entre ambos grupos, en términos de Amplitud, Duración, Gain y Velocidad Pico. Se hallaron diferencias entre los grupos para el parámetro Latencia, en los valores correspondientes a amplitudes visuales mayores de 45 grados. En el movimiento antisacádico con amplitudes visuales de 10 y 20 grados se encontraron diferencias significativas en este mismo parámetro. | |
| dc.description.abstractenglish | The present study was constituted of two parts. The first part was the design and implementation of a software tool for the filtration, characterization and statistical analysis of electrooculographic signals. The second part corresponds to the software tool application in a case-control study in schizophrenic patients, in which the possible association between the alteration of saccadic ocular movements and the schizophrenia was explored. 50 patients with clinical diagnosis of schizophrenia and 50 healthy controls were included in the study. Three different kinds of measurements were taken to all the participants: a structured psychiatric interview, a detail optometric evaluation and an electrooculogram. The Wavelet transform algorithm and the Parks-McClellan algorithm for the low pass filters design were implemented for the signal filtration. The electrooculografic signal characterization permitted the detection of the regions in which sacadic movements were registered. For each one of the regions or saccades identified some parameters values were found: Amplitude, Duration, Gain, Latency and Speed. With these values a statistical analysis was made using the one-way ANOVA parametric method or the Kruscal-Wallis non-parametric method when the data were non-normal distributed. The statistical analysis of the study showed that there were not statistically significant differences between both groups in terms of the Amplitude, Duration, Gain and Speed parameters. Statically significant differences were found for the Latency parameter, in the values corresponding to greater visual amplitude of 45 degrees. In the antisaccadic movement with visual amplitude of 10 and 20 degrees were significant differences in this same latency parameter. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero de Sistemas | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/18684 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería de Sistemas | |
| dc.publisher.school | Escuela de Ingeniería de Sistemas e Informática | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Electrooculografía | |
| dc.subject | Señal Electrooculográfica | |
| dc.subject | Movimiento Sacádico | |
| dc.subject | Esquizofrenia | |
| dc.subject | Movimiento Antisacádico | |
| dc.subject | Transformada De Wavelet | |
| dc.subject | Algoritmo De Parks-Mcclellan | |
| dc.subject | Caracterización | |
| dc.subject | Filtrado. | |
| dc.subject.keyword | Electrooculography | |
| dc.subject.keyword | Electrooculographic Signal | |
| dc.subject.keyword | Saccadic Movement | |
| dc.subject.keyword | Schizophrenia | |
| dc.subject.keyword | Antisaccadic Movement | |
| dc.subject.keyword | Wavelet Transform | |
| dc.subject.keyword | Parks-Mcclellan Algorithm | |
| dc.subject.keyword | Characterization | |
| dc.subject.keyword | Filtrate. | |
| dc.title | Software para la caracterización y análisis estadístico de la señal electrooculografica, usado en la determinación de asociación entre alteración de movimientos oculares sacádicos y esquizofrenia | |
| dc.title.english | Software for the characterization and statistical analysis of electrooculographic signal, used in tthe determination of association between alteration of ocular sacadics movements and schizophrenia. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |