Publicación: Análisis del coeficiente de disipación de energía "r" para una edificación incorporando interacción suelo estructura
| dc.contributor.advisor | Zapata Orduz, Luis Eduardo | |
| dc.contributor.advisor | Cotes Prieto, David Sebastian | |
| dc.contributor.author | Bravo Rivera, Juan David | |
| dc.date.accessioned | 2024-03-04T00:41:16Z | |
| dc.date.available | 2020 | |
| dc.date.available | 2024-03-04T00:41:16Z | |
| dc.date.created | 2020 | |
| dc.date.issued | 2020 | |
| dc.description.abstract | El estudio del comportamiento sísmico de las edificaciones ha demostrado que su capacidad, medida en términos del coeficiente modificación de respuesta sísmica R, se ve considerablemente afectada por la interacción suelo-estructura (ISE). Sin embargo, hay poca información sobre el efecto de este fenómeno en el coeficiente R para edificaciones que involucran muros estructurales, debido al alto costo computacional que demandan estos modelos. Por lo tanto, este proyecto de investigación estudia el efecto de la ISE sobre R, mediante un caso de estudio de una edificación irregular con muros estructurales y un sistema de cimentación de zapatas aisladas cargadas excéntricamente a través de un modelo de análisis no lineal estático de plasticidad concentrada computacionalmente eficiente, en el software SAP-2000. Se estudiaron los efectos de un suelo con velocidades de onda de corte (Vs) entre 360 (m/s) y 180 (m/s), modelados como resortes discretos e independientes contemplando la plasticidad del suelo y el levantamiento de los cimientos. Se determinaron las curvas de capacidad y los valores de R en la dirección no simétrica Y en sentido negativo (-Y) y positivo (+Y) y en la dirección X, para 39 modelos con pandeo; i) 1 modelo restringido en la base, ii) 19 modelos con comportamiento lineal del suelo, iii) y 19 modelos con comportamiento no lineal del suelo. Se compararon los resultados obtenidos de R respecto al modelo restringido en la base encontrando que los valores de R aumentaron al incluir los efectos de ISE siendo más notorio este cambio en la dirección X donde la fuerza sísmica afectó a los muros fuera del plano, presentándose valores de R promedio con respecto al modelo restringido en la base en las direcciones X, +Y y -Y para suelo lineal de 103%, 12.7% y 2% y para suelo no lineal de 104%, 12.7% y 2.2%, respectivamente. | |
| dc.description.abstractenglish | The study of seismic behavior on buildings has demonstrated that its capacity measured in terms of response reduction factor R is considerably affected by soil-structure interaction (ISE, by its acronym in Spanish). Although, there is few information about the effect of this phenomena in the R coefficient for buildings with structural walls due to the high computational cost demanded by the models. Therefore, this research project studies the effect of ISE on R through a case of study of an irregular building with structural walls and an isolated footings foundation system loaded eccentrically by means of a nonlinear static analysis model of concentrated plasticity computationally efficient using the software SAP-2000. Capacity curves and R coefficients were determined in the non-symmetric direction Y for positive axis (+Y) and negative axis (-Y) and in X direction, for 39 models with buckling: i) 1 model fixed at base ii) 19 models with linear soil behavior iii) and 19 models with nonlinear soil behavior. The R coefficients results obtained were compared respect the fixed model finding that R coefficient increase due to the ISE effects being more noticeable this change in X direction where the seismic force affected the walls out of plane, presenting average values of R coefficient respect the fixed model in X, +Y and -Y directions to the lineal soil of 103%, 12.7% y 2% and to the nonlinear soil of 104%, 12.7% and 2.2%, respectively. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Civil | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/39863 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Civil | |
| dc.publisher.school | Escuela de Ingeniería Civil | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Pandeo fuera del plano | |
| dc.subject | Interacción suelo-estructura | |
| dc.subject | Plasticidad concentrada | |
| dc.subject | Plasticidad distribuida | |
| dc.subject | Coeficiente de modificación de respuesta R. | |
| dc.subject.keyword | Out of plane buckling; Soil-structure interaction; Concentrated plasticity; Distributed plasticity; Response reduction factor R. | |
| dc.title | Análisis del coeficiente de disipación de energía "r" para una edificación incorporando interacción suelo estructura | |
| dc.title.english | Alysis for a building incorporating soilstructure interaction * | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 209.87 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 187.03 KB
- Formato:
- Adobe Portable Document Format