Publicación: Verificación experimental de un algoritmo para localización de falla eléctricas de tipo monofásico
| dc.contributor.advisor | Álzate Castaño, Ricardo | |
| dc.contributor.advisor | Carrillo Caicedo, Gilberto | |
| dc.contributor.author | Diaz González, Jose David | |
| dc.contributor.author | Ramírez Cubillos, Erson Darío | |
| dc.date.accessioned | 2024-03-03T20:09:07Z | |
| dc.date.available | 2013 | |
| dc.date.available | 2024-03-03T20:09:07Z | |
| dc.date.created | 2013 | |
| dc.date.issued | 2013 | |
| dc.description.abstract | El presente proyecto de grado aborda el análisis, diseño e implementación de 2 algoritmos para localización de fallas eléctricas de tipo monofásico, en un prototipo de laboratorio. Como estrategias de localización se utilizan los métodos de la reactancia y Takagi, seleccionados por medio de una investigación literaria basada en investigaciones previas realizadas en la UIS, destacando su viabilidad para ser implementados en un dispositivo lógico programable, para predecir la ubicación de un fallo a tierra en un modelo de línea corta representado por resistencias e inductancias distribuidas uniformemente en una distancia de 5 [m]. Se exponen las etapas que conforman el sistema de pruebas, de las cuáles se realiza una descripción de su diseño e implementación, así como también de los elementos seleccionados para su construcción. Los algoritmos seleccionados fueron inicialmente analizados y validados mediante rutinas de simulación en MATLAB® y posteriormente adecuados para su implementación en un microcontrolador MCF51QE128 de FREESCALE®. Se describe detalladamente el método algorítmico implementado para la detección y localización de fallas eléctricas. Como resultado principal se obtuvo la localización de dos fallas consecutivas inducidas en diferentes secciones y la reconfiguración automática de la topología de la línea de transmisión, en un prototipo de laboratorio. A manera de trabajo futuro se propone el estudio de técnicas más complejas para detección y localización de fallas eléctricas como parte del concepto de relés digitales aplicados al contexto de las redes inteligentes. 1 | |
| dc.description.abstractenglish | This degree project is aimed at analyzing, designing and implementing two algorithms to locate line-to-ground fault in single-phase electrical systems, in a prototype working model. As localization strategies the reactance and Takagi techniques were used, selected through a literature review based on previous research carried out in the UIS, highlighting its feasibility to be implemented in a programmable logic device to predict the location of a ground fault in a short line model represented by resistors and inductors uniformly distributed over a distance of 5 [m]. It explains the stages in the test system, from which a description of the design and implementation is made as well as the selected items for its construction. The selected algorithms have been simulated and validated in MATLAB® and implemented in a MCF51QE128 FREESCALE® microcontroller. It describes in detail the implemented algorithm method for detection and localization of electrical faults. As a main result, it was obtained the localization of two consecutive faults induced in different sections and the automatic reconfiguration of the topology of the transmissión line, in a laboratory prototype. Ongoing work includes analysis of more complex techniques for the localization of electrical faults as part of the computer relaying topic in the context of smart-grid applications. 3 | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/29246 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Fallas Eléctricas | |
| dc.subject | Redes Inteligentes | |
| dc.subject | Relé Digital | |
| dc.subject | Algoritmo De Takagi. | |
| dc.subject.keyword | Electrical Faults | |
| dc.subject.keyword | Smart-Grid | |
| dc.subject.keyword | Computer Relaying | |
| dc.subject.keyword | Takagi Algorithm. | |
| dc.title | Verificación experimental de un algoritmo para localización de falla eléctricas de tipo monofásico | |
| dc.title.english | Experimental verification of a single-line fault detection and localization algorithm. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 702.12 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 453.22 KB
- Formato:
- Adobe Portable Document Format