Publicación: Caracterización mecánica del biomaterial PEEK con fibra de carbono para aplicación médica en el diseño de prótesis articular ATM
| dc.contributor.advisor | González Estrada, Octavio Andrés | |
| dc.contributor.advisor | Mejía Rodríguez, Manuel Alejandro | |
| dc.contributor.author | Macías Rincón, Yeison Stiven | |
| dc.contributor.evaluator | Villegas Bermudez, Diego Fernando | |
| dc.contributor.evaluator | Sanchez Acevedo, Heller Guillermo | |
| dc.date.accessioned | 2025-11-19T12:18:09Z | |
| dc.date.available | 2025-11-19T12:18:09Z | |
| dc.date.created | 2025-11-18 | |
| dc.date.issued | 2025-11-18 | |
| dc.description.abstract | Los materiales tradicionalmente usados en prótesis para la articulación temporomandibular (ATM), como el Ti-6Al-4V o cobalto-cromo tienen problemas como liberación de partículas, osteólisis y el blindaje óseo. En este contexto, el polieteretercetona reforzado con fibra de carbono (CFR-PEEK) es una alternativa prometedora como biomaterial en el diseño de este tipo de prótesis. Por tal razón el objetivo de esta investigación fue caracterizar este material mediante pruebas de compresión y flexión bajo normativas ASTM, para compararlo con la aleación de titanio y determinar qué tan viable es el CFR-PEEK en aplicaciones médicas. El análisis de normas llevo a seleccionar la ASTM D790 (flexión en 3 puntos) y ASTM D695 (compresión) como las más adecuadas para caracterizar este material, se fabricaron probetas estandarizadas y se ensayaron en una prensa MTS, registrado curvas de carga-desplazamiento y esfuerzo-deformación. Identificando que para flexión el material presentó un comportamiento elástico lineal en la zona inicial, con una fractura progresiva con microgrietas, alcanzando cargas máximas de 468,7 N, esfuerzo de 527,8 Mpa y un módulo en flexión de 92,1 Gpa. En compresión se identificó la falla por presencia y propagación de grietas diagonales, obteniendo una resistencia máxima de 174 Mpa, módulo de elasticidad de 6,55 Gpa al someter las muestras a cargas máximas de 22 KN. Aunque las propiedades mecánicas del Ti-6Al-4V son superiores, se demostró que la rigidez y resistencia del CFR-PEEK son similares al hueso cortical, reduciendo el blindaje óseo y mejorando su compatibilidad. Respaldando la viabilidad de usarlo como material alternativo en prótesis de ATM, aportando una metodología estandarizada y datos experimentales relevantes para la comprensión de nuevos biomateriales. | |
| dc.description.abstractenglish | Materials traditionally used in temporomandibular joint (TMJ) prostheses, such as Ti-6Al-4V or cobalt-chromium, suffer from problems such as particle release, osteolysis, and bone sheathing. In this context, carbon fiber-reinforced polyetheretherketone (CFR-PEEK) is a promising alternative biomaterial for the design of this type of prosthesis. For this reason, the objective of this research was to characterize this material through compression and flexural testing under ASTM standards, to compare it with titanium alloy and determine the viability of CFR-PEEK in medical applications. The analysis of standards led to the selection of ASTM D790 (3-point bending) and ASTM D695 (compression) as the most appropriate to characterize this material. Standardized specimens were manufactured and tested in an MTS press, recording load-displacement and stress-strain curves. The material exhibited linear elastic behavior in the initial flexural zone, with progressive fracture with microcracks, reaching maximum loads of 468.7 N, a stress of 527.8 MPa, and a flexural modulus of 92.1 Gpa. In compression, failure was identified by the presence and propagation of diagonal cracks, obtaining a maximum strength of 174 Mpa and an elastic modulus of 6.55 Gpa when the samples were subjected to maximum loads of 22 KN. Although the mechanical properties of Ti-6Al-4V are superior, the stiffness and strength of CFR-PEEK were shown to be similar to cortical bone, reducing bone shielding and improving its compatibility. This supports the feasibility of using it as an alternative material in TMJ prostheses, providing a standardized methodology and relevant experimental data for understanding new biomaterials. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Mecánico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/46551 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
| dc.publisher.program | Ingeniería Mecánica | |
| dc.publisher.school | Escuela de Ingeniería Mecánica | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Articulación temporomandibular | |
| dc.subject | polieteretercetona reforzado con fibra de carbono | |
| dc.subject | compresión axial | |
| dc.subject | flexión a tres puntos | |
| dc.subject | ASTM D695 | |
| dc.subject | ASTM D790 | |
| dc.subject | Modulo en flexión | |
| dc.subject | Modulo en compresión | |
| dc.subject | esfuerzo | |
| dc.subject | deformación | |
| dc.subject | desplazamiento | |
| dc.subject | fuerza | |
| dc.subject.keyword | Temporomandibular joint | |
| dc.subject.keyword | carbon fiber reinforced polyetheretherketone | |
| dc.subject.keyword | axial compression | |
| dc.subject.keyword | three-point bending | |
| dc.subject.keyword | ASTM D695 | |
| dc.subject.keyword | ASTM D790 | |
| dc.subject.keyword | Flexural modulus | |
| dc.subject.keyword | Compressive modulus | |
| dc.subject.keyword | stress | |
| dc.subject.keyword | strain | |
| dc.subject.keyword | displacement | |
| dc.subject.keyword | force | |
| dc.title | Caracterización mecánica del biomaterial PEEK con fibra de carbono para aplicación médica en el diseño de prótesis articular ATM | |
| dc.title.english | Mechanical characterization of the PEEK biomaterial with carbon fiber for medical application in the design of TMJ joint prostheses | |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 149.23 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 132.39 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: