Publicación: Implementación de un montaje para caracterizar oxihemoglobina basado en espectroscopia de infrarrojo cercano de onda continua (nir-cw)
| dc.contributor.advisor | Meneses Fonseca, Jaime Enrique | |
| dc.contributor.advisor | Miranda Mercado, David Alejandro | |
| dc.contributor.author | Torres Melo, Carmen Eveth | |
| dc.contributor.author | Plata Planidina, Alexandra | |
| dc.date.accessioned | 2024-03-03T17:03:38Z | |
| dc.date.available | 2008 | |
| dc.date.available | 2024-03-03T17:03:38Z | |
| dc.date.created | 2008 | |
| dc.date.issued | 2008 | |
| dc.description.abstract | La alta incidencia de cáncer de mama plantea la necesidad de implementar técnicas alternativas que contribuyan a la detección temprana de cáncer. El crecimiento de los tumores exige el aporte de oxígeno y nutrientes a través del riego sanguíneo, lo cuál implica un aumento en el número de vasos sanguíneos en el intersticio del tejido, proceso denominado angiogénesis. Una forma de determinar la presencia de angiogénesis es midiendo la cantidad de oxigeno local que se encuentra en la sangre. Por otro lado, La mayoría de los tejidos biológicos son transparentes a la radiación infrarroja (700 a 900 nm). Cuando se irradia el tejido, ocurren fenómenos de reflexión, absorción y dispersión que alteran la intensidad luminosa de la radiación de salida. De esta forma detectando la intensidad luminosa de una radiación infrarroja al atravesar un espesor de tejido, se puede recuperar información morfológica e histológica correspondiente al estado actual del tejido. Existen variables que afectan la intensidad de radiación de salida, principalmente intervienen las concentraciones de los centros absorbentes, para el caso del tejido subcutáneo, la concentración de Oxihemoglobina, desoxihemoglobina y agua. De esta manera, utilizando tres longitudes de onda y detectando sus intensidades de salida, se puede establecer un sistema de tres ecuaciones con tres incógnitas, a partir de la ecuación básica que interviene en la absorción: Ley de Beer-Lambert. Según lo anterior, el objetivo del presente proyecto es determinar si las alteraciones de concentraciones de oxígeno en sangre afectan la intensidad de salida de la radiación luminosa de tres longitudes de onda en el rango infrarrojo. Se implementó un dispositivo opto-electrónico y se comprobó que las concentraciones de oxígeno afectan la intensidad de la radiación de salida. Este proyecto es la primera fase de un proyecto que busca implementar un equipo para la detección temprana de cáncer de mama. | |
| dc.description.abstractenglish | The high incidence of breast cancer raises the need to implement alternative techniques that contribute to the early cancer detection. The growth of tumors requires of nutrients and oxygen through the blood supply, which means an increase in the number of blood vessels in the interstitial tissue, process called angiogenesis. One way to determinate the presence of angiogenesis is measuring the oxygen concentration found locally in the blood. The majority of biological tissues are transparent to infrared radiation (700 to 900 nm). When the tissue is irradiated, phenomena of reflection, scattering and absorption occurring and alter the light intensity of the output radiation. In this way measuring the light intensity of infrared radiation passing through the tissue, this retrieves morphological and histological information of tissue state. There are several variables that affect the output radiation, mainly the presence of absorbing centers that in the case of subcutaneous tissue are the concentration of Oxihemoglobin, desoxihemoglobin and water. In this way, using three wavelengths and detecting their intensities after passing the tissue, it can establish a system of three equations with three unknowns, from the basic equation involved in the absorption: Beer-Lambert Law. According to the above, the objective of this project is to determine if alterations in oxygen concentrations in the blood affect the intensity of the radiation in three wavelengths in the infrared range. It was implemented an opto-electronic device and was found that the concentration of oxygen affects the output intensity of the threes wavelengths used. This project is the first phase of a project that to look for to implement a device for the early detection of breast cancer. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/21062 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Angiogénesis | |
| dc.subject | Radiación infrarroja | |
| dc.subject | Absorción | |
| dc.subject | Dispersión | |
| dc.subject | Longitud de onda | |
| dc.subject | oxihemoglobina | |
| dc.subject | desoxihemoglobina. | |
| dc.subject.keyword | Angiogenesis | |
| dc.subject.keyword | Infrared radiation | |
| dc.subject.keyword | Scattering | |
| dc.subject.keyword | Absorption | |
| dc.subject.keyword | Wavelengths | |
| dc.subject.keyword | oxihemoglobin | |
| dc.subject.keyword | desoxihemoglobin. | |
| dc.title | Implementación de un montaje para caracterizar oxihemoglobina basado en espectroscopia de infrarrojo cercano de onda continua (nir-cw) | |
| dc.title.english | Implementation of an assembly to characterize oxihemoglobin based on continuous wave near infrared spectroscopy (nir-cw)*. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 227.47 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 308.01 KB
- Formato:
- Adobe Portable Document Format
