Logotipo del repositorio

Publicación:
Determinación de la concentración de un inhibidor químico para retardar el pardeamiento de fresa deshidratada

dc.contributor.advisorLópez Giraldo, Luis Javier
dc.contributor.authorBecerra Navas, Javier Oswaldo
dc.contributor.authorSilva Silva, Jose Miguel
dc.date.accessioned2024-03-04T00:08:45Z
dc.date.available2018
dc.date.available2024-03-04T00:08:45Z
dc.date.created2018
dc.date.issued2018
dc.description.abstractPara la empresa Sensafruit S.A.S la fresa deshidratada representa un 20% de su producción anual, pero estas presentan problemas de pardeamiento total de tres a cuatro meses de producción, generándose pérdida del producto. Se ha relacionado las reacciones de pardeamiento como una cadena de reacciones de oxidación de polifenoles a quinonas catalizada por la enzima polifenoloxidasa (PPO). En las reacciones mediadas por la PPO influyen factores como la humedad del alimento, la presencia de luz y oxígeno; por tanto, un estudio para la implementación de un método que retarde el pardeamiento, y mejoramiento en el secado, contribuirá a obtener una estabilidad visual. Se realizó un montaje de cinco cámaras manipulando la humedad interna, y exposición de luz con el objetivo de acelerar la reacción de pardeamiento y realizar un seguimiento de color; además se realizó un análisis bibliográfico y experimental para seleccionar la concentración del inhibidor (ácido ascórbico y cítrico), se usaron como variables de respuesta del contenido de polifenoles totales, la capacidad antioxidante y el tiempo de pardeamiento como criterio final. Por último, se realizaron pruebas de secado en un deshidratador de bandejas a 45,55,65 y 75°C; el objetivo de esto fue determinar la temperatura de procesamiento que aumenta el tiempo en que se inicia el pardeamiento del producto, una vez ésta ha sufrido el proceso de inhibición descrito anteriormente. Para tal fin, se usaron como criterios la apariencia física, humedad y tiempo. Se obtuvó como resultado una concentración de ácido ascórbico de 45mM en el proceso de pretratamiento, junto con una temperatura de 65°C y una velocidad de aire de 6 m/s en el proceso de deshidratación, aumentan el tiempo de inicio de pardeamiento según el consumidor de 3 a 4.8 semanas. Bajo estas condiciones se obtiene un producto deshidratado con una humedad final de 13.02%.
dc.description.abstractenglishThe unsatisfied demand in Colombia, regarding the calibration of low pressures, is mainly due to the lack of secondary patterns that provide low uncertainty and have ONAC certification. The purpose of this research is to take the Dwyer 1425 Series Hook Gage communicating vessel pattern from the Gas CDT laboratory and modify it, in such a way that its uncertainty estimated by the GUM method is lower than the original one and therefore it is enabled to perform calibrations. To accomplish this aim, the uncertainty in the original pattern is first estimated to identify the sources of variability that most contribute to doubt in the measurements, from which it was obtained that the level measurement in the vessels is the most relevant source, due to its lack of precision. Secondly, 4 proposals focused on a decrease in the contribution by the level measurements were designed, to later choose one of these proposals based on the cost and the uncertainty, from which it was obtained that the best option is to suppress the measurement level in a vessel and incorporate optical improvements in the other to continue level measurements with micrometer. Finally, the differences of uncertainty between the original, modified pattern and the required uncertainty were compared, from there a significant gap was obtained between the original and modified uncertainty of pattern, in addition a compliance in the laboratory requirements was achieved in a manometric range of 2.5 kPa to 5.2 kPa, in pressure and vacuum.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/38978
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectPolifenoloxidasa
dc.subjectPardeamiento Enzimático
dc.subjectSistema Rgb Y Fresa Deshidratada..
dc.subject.keywordCommunicating Vessels
dc.subject.keywordUncertainty
dc.subject.keywordSource Of Variability
dc.subject.keywordContribution Of Uncertainty
dc.subject.keywordGum Method
dc.subject.keywordAccuracy.
dc.titleDeterminación de la concentración de un inhibidor químico para retardar el pardeamiento de fresa deshidratada
dc.title.englishDecrease of the uncertainty of a communicating vessel pattern for pressure calibration, with a manometric range of -5.2 kpa to 5.2 kpa*
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
149.6 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
1.49 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
121.39 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031