Publicación: Simplificación tecnológica del dispositivo de visión artificial para la auditoría y control del lavado de manos en centros hospitalarios: "MANITOR"
| dc.contributor.advisor | Salamanca Becerra, William Alexander | |
| dc.contributor.advisor | Orozco-Levi, Mauricio | |
| dc.contributor.advisor | Sierra Bueno, Daniel Alfonso | |
| dc.contributor.author | Perez Caceres, Sonia | |
| dc.contributor.author | Rovira Gomez, Maria Fernanda | |
| dc.date.accessioned | 2024-03-03T23:57:15Z | |
| dc.date.available | 2018 | |
| dc.date.available | 2024-03-03T23:57:15Z | |
| dc.date.created | 2018 | |
| dc.date.issued | 2018 | |
| dc.description.abstract | El presente trabajo muestra el desarrollo de un prototipo que guía y audita el lavado de manos bajo el protocolo establecido por la Organización Mundial de la Salud (OMS) con el fin de combatir y mitigar las infecciones asociadas a la atención en salud (IAAS). Surge como una simplificación a nivel de hardware y software del modelo funcional MANITOR desarrollado por la Fundación y equivale a la proyección de videos en una tablet detrás de un espejo con aspecto de vidrio polarizado ubicado en el sitio de lavado. Este dispositivo probó ser una innovación que promueve la higiene de manos completa disminuyendo de manera considerable el inóculo bacteriano de las manos. Para lograr la simplificación se establecieron los requerimientos mínimos computacionales del dispositivo, se eligieron los elementos de hardware y software a implementar, a través de unos parámetros de selección fijados durante el desarrollo, se diseñaron una serie de algoritmos que permiten detectar la presencia de un usuario, reconocer piel y el movimiento de las manos e instruir el paso a paso del lavado. Para medir el desempeño del prototipo, se realizaron pruebas en el Hospital Internacional de Colombia (HIC), en donde se obtuvo 97,25% de sensibilidad, 90% de especificidad y logró una disminución de costo del 66.67% respecto al modelo funcional MANITOR. | |
| dc.description.abstractenglish | This paper shows the development of a prototype that guides and audits hand washing under the protocol established by the World Health Organization (WHO) to combat and mitigate healthcare-associated infections (HAI). It is created as a hardware and software simplification of the functional model MANITOR, developed by the Cardiovascular Foundation of Colombia (FCV), its name is derived from the acronym "MANos" and "moniTORización" and is equivalent to a projection of videos on a tablet behind a mirror with polarized glass appearance located in the wash room. This device proved to be an innovation that promotes complete hand hygiene by considerably reducing the bacterial inoculum of the hands. To achieve the simplification, a minimum of computational requirements were stablished, implementable hardware and software elements were chosen through selection parameters set during the development, as well as a series of algorithms designed to detect the presence of a user, recognize skin and hand movements and instruct every step of the washing protocol. To measure the performance of the prototype was tested in the International Hospital of Colombia (HIC), where a 97.25% of sensitivity and 90% of specificity were obtained. Also, a decrease of 66.67% in cost was achieved beside the functional model MANITOR. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/37845 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Lavado De Manos | |
| dc.subject | Visión Artificial | |
| dc.subject | Opencv | |
| dc.subject | Optical Flow | |
| dc.subject.keyword | Hand Wash | |
| dc.subject.keyword | Artificial Vision | |
| dc.subject.keyword | Opencv | |
| dc.subject.keyword | Optical Flow | |
| dc.title | Simplificación tecnológica del dispositivo de visión artificial para la auditoría y control del lavado de manos en centros hospitalarios: "MANITOR" | |
| dc.title.english | Technological simplification of the artificial vision device for the audit and control of hand washing in hospital centers: "manitor* | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 539.06 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 164.83 KB
- Formato:
- Adobe Portable Document Format