| dc.description.abstract | En este trabajo de grado se implementó un circuito para controlar el grabado electroquímico de filamentos metálicos que pueden ser utilizados en técnicas de microscopía y espectroscopía de sonda local. En particular, el ataque electroquímico se desarrolló disponiendo un filamento de plata (ánodo) y un contra electrodo (cátodo). El electrolito consistió en una solución de ácido perclórico y metanol en proporción de 1:4, respectivamente. El acabado de las puntas, para una misma longitud de hilo sumergido en la solución, se controló estableciendo una tensión de referencia a un circuito comparador, el cual garantiza la reproducibilidad de la punta tallada a este valor de tensión. Además, por medio de un osciloscopio Fluke 199B Scopemeter 200 MHz se trazó la curva de la caída de tensión en el cátodo, en la cual se obtuvo cutoff time aproximado de 140 ns, producto de la velocidad de conmutación de los transistores de efecto campo (MOSFET). La evaluación del hilo tallado se realizó a través de imágenes de microscopía óptica y electrónica de barrido. Se evidencia con estas imágenes que a valores muy altos del voltaje de referencia, el grabado del filamento queda incompleto y a valores muy bajos se obtienen puntas con exceso de tallado, provocando una geometría roma en el ápice del filamento atacado electroquímicamente. Sin embargo, es posible aliviar estas situaciones extremas en un cierto rango de valores para la tensión de referencia. i | |
| dc.description.abstractenglish | In this work, a circuit to control the electrochemical etching of metallic filaments, which can be used in microscopy and spectroscopy, was implemented. In particular, the electrochemical attack was developed using a silver filament (anode) and a counter electrode (cathode). The electrolyte consisted in a solution of perchloric acid and methanol in a ratio of 1:4, respectively. The profile of the tips, for the same length of wire submerged into the solution, was controlled establishing a reference voltage to a comparator circuit, warranting the reproducibility of the profile at this voltage. In addition, the voltage at the cathode was tracked using a Fluke 199B scopemeter oscilloscope. It was obtained a cutoff time of approximately 140 ns, which result of the switching speed of field effect transistors (MOSFET). The assessment of the tips was done through optical microscopy and scanning electron microscopy imaging. It evidenced with this images that at very high values of the reference voltage, the etching of the tip is incomplete and at very low values, tips with excess of etching were obtained, by generating a blunt geometry at the apex of the filament etched. However, it is possible to alleviate these extreme situations in a certain range of values for the reference voltage. iii | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/37046 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Control | |
| dc.subject | Grabado Electroquímico. | |
| dc.subject.keyword | Control | |
| dc.subject.keyword | Electrochemical Etching. | |
| dc.title | Diseño de un circuito de control para el grabado electroquímico de puntas metálicas usadas en microscopia y espectroscopia de sonda local | |
| dc.title.english | Design of a control circuit for the electrochemical etching of metal tips used in microscopy and spectroscopy of local probe.iii | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 453.68 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 248.8 KB
- Formato:
- Adobe Portable Document Format