Publicación: Estudio paramétrico del comportamiento histerético de disipadores de placas ranuradas usando las herramientas de Ansys Workbench
| dc.contributor.advisor | Begambre Carrillo, Óscar Javier | |
| dc.contributor.advisor | Guevara Corzo, Jeffrey | |
| dc.contributor.advisor | Mendoza Cuy, Angie Paola | |
| dc.contributor.author | Suárez Marín, Yelin Patricia | |
| dc.contributor.author | Báez Vargas, Paula Daniela | |
| dc.contributor.evaluator | Zapata Orduz, Luis Eduardo | |
| dc.contributor.evaluator | Benjumea Royero, José Miguel | |
| dc.date.accessioned | 2022-04-18T13:59:47Z | |
| dc.date.available | 2022-04-18T13:59:47Z | |
| dc.date.created | 2022-04-12 | |
| dc.date.issued | 2022-04-12 | |
| dc.description.abstract | Con el paso de los años se han originado diferentes técnicas de disipación de energía sísmica, esto como solución ante la ocurrencia de eventos telúricos y fuertes vientos que afectan gravemente la respuesta dinámica de las edificaciones. Una de estas técnicas son los disipadores pasivos, que han sido un referente ampliamente estudiado por diferentes autores y dentro de sus resultados se consideran a los dispositivos histeréticos metálicos con ranuras como elementos con ciclos de histéresis estables, razón por la cual se pueden aplicar como la mejor alternativa de implementación en el diseño tradicional de edificaciones para países en vía de desarrollo como Colombia. Este estudio tuvo como objetivo analizar el comportamiento histerético de un disipador metálico con ranuras circulares. La investigación se realizó mediante un estudio paramétrico sobre 27 modelos de disipadores sometidos a un protocolo de carga cíclica. Para determinar la capacidad de disipación de los dispositivos se empleó el software de análisis estructural basado en elementos finitos Ansys Workbench. A partir de los resultados obtenidos en esta investigación, se concluye que la relación de aspecto de la placa del dispositivo es el factor con mayor influencia en su desempeño, resaltando que los disipadores con ranuras circulares de menor radio son los que presentan una mayor capacidad de disipación de energía. Finalmente, se determinó lo contraproducente que puede ser el que se dispongan orificios en una sola fila, debido a la concentración de esfuerzos en el material entre ranuras. | |
| dc.description.abstractenglish | Over the years, different seismic energy dissipation techniques have been developed as a solution to the occurrence of telluric events and strong winds that seriously affect the dynamic response of buildings. One of these techniques are the passive dissipators, which have been a reference widely studied by different authors and within their results, metallic hysteretic devices with slots are considered as elements with stable hysteresis cycles, reason why they can be applied as the best alternative for implementation in the traditional design of buildings for developing countries such as Colombia. The objective of this study was to analyze the hysteretic behavior of a metallic heatsink with circular slots. The research was carried out by means of a parametric study on 27 heatsink models subjected to a cyclic loading protocol. The finite element based structural analysis software Ansys Workbench was used to determine the dissipation capacity of the devices. From the results obtained in this research, it is concluded that the aspect ratio of the device plate is the factor with the greatest influence on its performance, highlighting that the heatsinks with circular slots of smaller radius are the ones that present a greater energy dissipation capacity. Finally, it was determined how counterproductive it can be to have holes in a single row, due to the concentration of stresses in the material between slots. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Civil | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/9907 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
| dc.publisher.program | Ingeniería Civil | |
| dc.publisher.school | Escuela de Ingenieria Civil | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Disipador | |
| dc.subject | Control sísmico | |
| dc.subject | Control pasivo | |
| dc.subject | Histéresis | |
| dc.subject | Edificaciones | |
| dc.subject.keyword | Dissipator | |
| dc.subject.keyword | Seismic control | |
| dc.subject.keyword | Passive control | |
| dc.subject.keyword | Hysteresis | |
| dc.subject.keyword | Buildings | |
| dc.title | Estudio paramétrico del comportamiento histerético de disipadores de placas ranuradas usando las herramientas de Ansys Workbench | |
| dc.title.english | Parametric study of the hysteretic behavior of slotted plate heatsinks using Ansys Workbench tools | |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 319.05 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 82.95 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.18 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: