Estrategias para minimizar costos por perdidas por evaporación en la gasolina corriente almacenada en tanques de la planta TELBA de Barranquilla

dc.contributor.advisorCacua Pérez, Jenny Milena
dc.contributor.authorVilla Sánchez, Alberto Mario
dc.contributor.evaluatorLeón Bermúdez, Adán Yovani
dc.date.accessioned2023-11-24T14:25:37Z
dc.date.available2023-11-24T14:25:37Z
dc.date.created2023-11-10
dc.date.embargoEnd2028-11-10
dc.date.issued2023-11-10
dc.description.abstractEl presente estudio tuvo como objeto analizar las pérdidas por evaporación en la gasolina corriente almacenada en los tanques 1002 y 1004 de planta TELBA, por el periodo de 6 meses para luego proponer y analizar estrategias para minimizar costos que son causados por estas pérdidas. Inicialmente los inspectores de Bureau Veritas Colombia Ltda, recopilaron datos diarios de campos operativos en la ejecución del servicio de certificación de cantidad y calidad, que actualmente es prestado a planta TELBA y así mismo se caracterizó el producto en el laboratorio de Bureau Veritas para conocer y asegurar que la calidad del producto es la estipulada contractualmente por Ecopetrol. Se tomaron mediciones estáticas en los tanques como; nivel de producto, temperatura del líquido y temperatura ambiente, para certificar los volúmenes recibidos, transferidos y entregados por Ecopetrol. Estos datos fueron utilizados para realizar los cálculos por perdidas por evaporación de la gasolina corriente diariamente almacenada en los tanques mencionados. Los resultados de las pérdidas por evaporación para el tanque 1002 por almacenamiento estacionario fueron de 48,23 bbls y por vaciado y llenado de 268,93 bbl para un total de 317,16 bbl. Para el tanque 1004 se calcularon perdidas por almacenamiento estacionario por valor de 50,08 bbl y por vaciado y llenado de 274,6 bbl para un total de 324,68 bbl. Seguido a esto se calcularon perdidas por evaporación, contemplando el supuesto de que los tanques tuvieran membranas internas. Estos últimos cálculos mencionados, arrojaron números inferiores que mejoraron los porcentajes de pérdidas no identificadas operativas en planta TELBA y en los costos extras por incumplimiento en el porcentaje permisible por Ecopetrol. Se realizaron comparativos en los balances de la planta, teniendo en cuenta las perdidas por evaporación con y sin membrana interna. Y finalmente se propusieron dos estrategias para analizar y verificar de manera muy sencilla la viabilidad de invertir en membranas internas para los tanques de almacenamiento y/o la implementación vitalicia de una herramienta informática en Excel propiedad de Bureau Veritas, que sería menos costosa. Teniendo esta última estrategia más viabilidad que la primera, como lo demuestran los resultados obtenidos en el presente estudio.
dc.description.abstractenglishThe purpose of this study was to analyze evaporation losses in gasoline stored in tanks 1002 and 1004 of TELBA plant, for a period of 6 months and then propose and analyze strategies to minimize costs caused by these losses. Initially, Bureau Veritas Colombia Ltda. inspectors collected daily data from operational fields in the execution of the quantity and quality certification service, which is currently provided to the TELBA plant, and also characterized the product in the Bureau Veritas laboratory to know and ensure that the quality of the product is as contractually stipulated by Ecopetrol. Static measurements were taken in the tanks, such as product level, liquid temperature and ambient temperature, to certify the volumes received, transferred and delivered by Ecopetrol. These data were used to calculate the evaporation losses of the gasoline stored daily in the aforementioned tanks. The results of evaporation losses for tank 1002 for stationary storage were 48.23 bbls and for emptying and filling 268.93 bbls for a total of 317.16 bbls. For tank 1004, stationary storage losses were calculated at 50.08 bbls and emptying and filling losses at 274.6 bbls for a total of 324.68 bbls. Evaporation losses were then calculated, assuming that the tanks had internal membranes. These last mentioned calculations yielded lower numbers that improved the percentages of unidentified operating losses in the TELBA plant and in the extra costs due to non-compliance with the percentage allowed by Ecopetrol. Comparisons were made in the balances of the plant, taking into account evaporation losses with and without internal membrane. And finally, two strategies were proposed to analyze and verify in a very simple way the feasibility of investing in internal membranes for the storage tanks and/or the lifetime implementation of an Excel software tool owned by Bureau Veritas, which would be less costly. The latter strategy was more feasible than the former, as demonstrated by the results obtained in this study.
dc.description.degreelevelEspecialización
dc.description.degreenameEspecialista en Gerencia de Hidrocarburos
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/15535
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programEspecialización en Gerencia de Hidrocarburos
dc.publisher.schoolEscuela de Ingeniería de Petróleos
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_f1cf
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectPerdidas por evaporación
dc.subjectReducción de costos
dc.subject.keywordEvaporation Losses
dc.subject.keywordCost Reduction
dc.titleEstrategias para minimizar costos por perdidas por evaporación en la gasolina corriente almacenada en tanques de la planta TELBA de Barranquilla
dc.title.englishStrategies to Minimize the Cost of Evaporation Losses in Gasoline Storade in Tanks at the TELBA Plant in Barranquilla
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Especialización
Files
Original bundle
Now showing 1 - 4 of 4
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
506.16 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
128.81 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de confidencialidad.pdf
Size:
160.98 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
1.36 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: