Caracterización dinámica de puentes en concreto de grandes luces de sección viga cajón construidos por voladizos sucesivos
dc.contributor.advisor | Riveros Jerez, Carlos Alberto | |
dc.contributor.advisor | Vivivescas Jaimes, Álvaro | |
dc.contributor.author | Hernández Sierra, Wilson Alexander | |
dc.contributor.evaluator | Chío Cho, Gustavo | |
dc.contributor.evaluator | Salgado Estrada, Rolando | |
dc.date.accessioned | 2022-04-01T03:57:00Z | |
dc.date.available | 2022-04-01T03:57:00Z | |
dc.date.created | 2021 | |
dc.date.issued | 2021 | |
dc.description.abstract | El monitoreo de salud estructural basado en vibraciones (SHM) es una herramienta útil para evaluar, verificar y estudiar el estado estructural de los puentes. Generalmente, las pruebas de vibración ambiental (AVT) o las pruebas de vibración forzada (FVT) se utilizan comúnmente para caracterizar la respuesta dinámica de los puentes, donde la selección de la prueba está en función del tipo de puente seleccionado y los recursos económicos disponibles, tanto AVT como FVT tienen ventajas y limitaciones que se han investigado en puentes con diferentes configuraciones estructurales. La ubicación, el número de sensores (acelerómetros) y el tiempo de recopilación de datos juegan un papel importante en la caracterización dinámica de los puentes. A nivel nacional, la construcción de puentes segmentales de concreto con vanos que van desde 50m 200m, o incluso con vanos mayores, se está convirtiendo recientemente en la tipología de puentes predominante. Por lo tanto, esta tipología está atrayendo más atención y, por lo tanto, el estudio de las ventajas y limitaciones de la caracterización dinámica de puentes utilizando AVT y / o FVT es vital en el contexto de una definición de un conjunto de ubicaciones óptimas para maximizar los recursos disponibles (número de acelerómetros y tiempo de recolección de datos entre otros). En esta investigación, AVT y FTV basados en fuentes de excitación seleccionadas de la revisión de la literatura y las simulaciones numéricas se llevan a cabo utilizando varias configuraciones de sensores. La metodología propuesta basada en la colocación óptima del sensor (OSP) muestra que los AVT que utilizan configuraciones de OSP proporcionan resultados similares a los obtenidos con los FVT sin considerar las configuraciones de OSP. Además, la relación de costo económico de FVT / AVT se reduce a 2 se logra un tiempo de recopilación de datos más corto con mejoras en los resultados. | |
dc.description.abstractenglish | Vibration-based structural health monitoring (SHM) is a useful tool for evaluating, verifying and studying structural condition of bridges. Generally, ambient vibration tests (AVT) or forced vibration tests (FVT) are commonly used to characterize the dynamic response of bridges, where the selection of the test is a function of the type of the selected bridge and available economic resources. Both AVT and FVT have advantages and limitations which have been investigated in bridges with different structural configurations. The location and number of sensors (accelerometers) and the data collection time play an important role in the dynamic characterization of bridges. At the national level, the construction of segmental concrete bridges with spans ranging from 50 m to 200 m, or even with larger spans is recently becoming the predominant bridge typology. Therefore, this typology is attracting more attention and thus the study of the advantages and limitations of bridge dynamic characterization using AVT and/or FVT is vital in the context of a definition of a set of optimal locations to maximize available resources (number of accelerometers and data collection time among others). In this research AVTs and FTVs based on excitation sources selected from the literature review and numerical simulations are conducted using various sensor configurations (dense array of sensors using longer data collection time and refined array of sensors optimally located using shorter data collection time). The proposed methodology based on optimal sensor placement (OSP) shows that AVTs using OSP configurations provide similar results to those obtained from FVTs without considering OSP configurations. Additionally, the FVT / AVT cost ratio is reduced to 2 since a shorter data collection time is achieved leading to improvements in AVT identification results, especially in vertical modes. | |
dc.description.degreelevel | Maestría | |
dc.description.degreename | Magíster en Ingeniería Civil | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/9450 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Maestría en Ingeniería Civil | |
dc.publisher.school | Escuela de Ingenieria Civil | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Identificación modal | |
dc.subject | Pruebas de vibración forzada | |
dc.subject | Vehículos | |
dc.subject | Óptima ubicación de sensores | |
dc.subject | Simulaciones numéricas | |
dc.subject.keyword | Modal Identification | |
dc.subject.keyword | Forced Vibration Test | |
dc.subject.keyword | Optimal Sensor Placement | |
dc.subject.keyword | Vehicles | |
dc.subject.keyword | Numerical Simulations | |
dc.title | Caracterización dinámica de puentes en concreto de grandes luces de sección viga cajón construidos por voladizos sucesivos | |
dc.title.english | Dynamic characterization of box girder bridges in concrete with large span built by successive cantilevers | |
dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Maestría | |
dspace.entity.type |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- 183168_licence.pdf
- Size:
- 1.02 MB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- 183168_nota.pdf
- Size:
- 1.62 MB
- Format:
- Adobe Portable Document Format
- Description: