Evaluación de métodos para la estabilización estructural de la cimentación de la catedral del Socorro – Santander
dc.contributor.advisor | Cruz Hernández, Ricardo Alfredo | |
dc.contributor.author | Peña Garcés, Sergio Alejandro | |
dc.contributor.author | Granadillo Ramos, José Armando | |
dc.contributor.evaluator | Zapata Orduz, Luis Eduardo | |
dc.contributor.evaluator | Benjumea Royero, José Miguel | |
dc.date.accessioned | 2022-06-08T11:31:26Z | |
dc.date.available | 2022-06-08T11:31:26Z | |
dc.date.created | 2021 | |
dc.date.issued | 2021 | |
dc.description.abstract | La Basílica Catedral de Nuestra Señora del Socorro se localiza en Socorro - Santander, es una estructura de patrimonio nacional que presenta una complejidad arquitectónica y estructural única en todo el país. Actualmente cuenta con una problemática estructural relacionada con su cimentación por tratarse de cimientos antiguos, con falencias en la estabilidad, un nivel freático cercano a la superficie, materiales de construcción con muy poca resistencia y una composición del subsuelo muy inestable. Además de factores constructivos también interviene un factor geológico, afectado en mayor grado por la actividad sísmica, debido a la localización geográfica con un alto grado de sismicidad. A lo largo del tiempo estos factores se han manifestado en forma de grietas en diferentes puntos de la cimentación con aberturas considerables que ponen en riesgo su integridad estructural. En este trabajo se evaluaron alternativas de métodos de estabilización estructural para una posible solución de la problemática. Los métodos que se evaluaron fueron los pilotes hincados a presión, recalce mediante inyecciones de compactación, hidro-fracturación, método de Jet Grouting y micropilotes. La evaluación fue realizada bajo los criterios de disponibilidad de equipos, eficiencia, compatibilidad con el tipo de terreno, facilidad de construcción, sosiego público y prefactibilidad según costos unitarios. El resultado de la evaluación es que el método recomendado para la rehabilitación de la cimentación de la catedral es la técnica de inyecciones de resinas expansivas de poliuretano. | |
dc.description.abstractenglish | The Cathedral Basilica of Our Lady of Socorro, located in Socorro - Santander, is a national heritage structure that presents a unique architectural and structural complexity. At the moment, the cathedral has a structural problem related to its old foundations, with weaknesses in stability, a water table close to the surface, construction materials with very little resistance and a very unstable subsoil composition. In addition to constructive factors, a geological factor also intervenes, affected to a greater degree by seismic activity, due to the geographical location with a high degree of seismicity. Through the time, these factors have manifested themselves in the form of cracks in different points of the foundation with considerable fractures that put its structural integrity at risk. In this work, alternative structural stabilization methods were evaluated for a possible solution of the problem. Five methods were evaluated like pressure driven piles, underlined by compaction injections, hydro-fracturing, Jet Grouting method and micropiles. The evaluation was carried out under the criteria of equipment availability, efficiency, compatibility with the type of land, ease of construction, public tranquility and pre-feasibility according to unit costs. As result, the compaction injection technique with expansive polyurethane resins is the recommended method for the rehabilitation of the Cathedral foundation. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Civil | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/11160 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Civil | |
dc.publisher.school | Escuela de Ingeniería Civil | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Estabilidad estructural | |
dc.subject | Cimentación | |
dc.subject | Edificaciones históricas | |
dc.subject | Riesgo | |
dc.subject | Rehabilitación estructural | |
dc.subject.keyword | Structural Stability | |
dc.subject.keyword | Foundations | |
dc.subject.keyword | Historic Buildings | |
dc.subject.keyword | Risk | |
dc.subject.keyword | Structural Rehabilitation | |
dc.title | Evaluación de métodos para la estabilización estructural de la cimentación de la catedral del Socorro – Santander | |
dc.title.english | Evaluation of methods for the structural stabilization of the foundation of the Socorro Cathedral – Santander | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- 183094_licence.pdf
- Size:
- 117.51 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- 183094_nota.pdf
- Size:
- 51.79 KB
- Format:
- Adobe Portable Document Format