Diseño de un sistema fotovoltaico en DC aislado para alimentar el telescopio de muones (mute) desarrollado por el Grupo de Investigación en Relatividad y Gravitación (GIRG)
dc.contributor.advisor | Bastidas Rodríguez, Juan David | |
dc.contributor.advisor | Quiroga Quiroga, Oscar Arnulfo | |
dc.contributor.author | Arenas Florez, Michael | |
dc.contributor.author | Perez Archila, Luis Miguel | |
dc.date.accessioned | 2024-03-03T23:22:52Z | |
dc.date.available | 2017 | |
dc.date.available | 2024-03-03T23:22:52Z | |
dc.date.created | 2017 | |
dc.date.issued | 2017 | |
dc.description.abstract | En la actualidad una de las soluciones utilizadas y de bajo impacto ambiental para suplir las necesidades del suministro de energía eléctrica para Zonas No Interconectas (ZNI), es la instalación de sistemas de generación fotovoltaica que operen de manera aislada. Si estos sistemas cuentan con una etapa de almacenamiento de energía y el suficiente recurso solar disponible en el sitio de instalación, pueden ser una alternativa técnica y ambientalmente viable para suplir las necesidades de suministro eléctrico en las zonas más apartadas del país. Con el desarrollo del telescopio de muones (MuTe) y su posterior implementación en una ZNI del territorio nacional, se presentó la necesidad de proyectar un sistema de alimentación que funcione de manera independiente del sistema interconectado. Es por esto que se planteó el diseño de un sistema fotovoltaico en DC aislado, con almacenamiento de energía. Teniendo en cuenta la reglamentación y normatividad colombiana (RETIE y NTC 2050) se realizó este diseño para hacer posible instalar y operar el MuTe en zonas apartadas del territorio nacional, en donde se encuentran localizados los volcanes activos que serán motivo de estudio por parte del grupo de investigación GIRG de la Universidad Industrial de Santander (UIS). Se encontró que los métodos generales de diseño de sistemas fotovoltaicos aislados no consideran dentro del proceso incluir el consumo de potencia de las protecciones eléctricas, debido a que el consumo de estas comparado con el consumo de la carga es muy bajo, sin embargo, para cargas de baja potencia y de régimen de uso permanente como las consideras en este proyecto o similares, es necesario considerar este consumo dentro del proceso del dimensionamiento. En este diseño se estimó que las pérdidas asociadas exclusivamente a las protecciones eléctricas corresponden aproximadamente al 50% de las pérdidas totales del sistema. | |
dc.description.abstractenglish | Currently, one of the solutions used and of low environmental impact to supply the needs of the electrical energy supply for Non-Interconnected Zones (NIZ), is the installation of photovoltaic generation systems that operate in stand-alone mode. If these systems have a stage of energy storage and sufficient solar resources available at the installation site, they can be a technically and environmentally viable alternative to meet the electricity supply needs in the most remote areas of the country. With the development of the muon telescope (MuTe) and its subsequent implementation in a Non-Interconnected Zone of the national territory, the need was presented to project a power system that works independently of the interconnected system. This is why the design of a stand-alone DC photovoltaic system with energy storage was proposed. Taking into account the Colombian regulations (RETIE and NTC 2050), this design was made to make it possible to install and operate the MuTe in remote areas of the national territory, where the active volcanoes are located, which will be the subject of study by the group of research GIRG of the Industrial University of Santander (UIS). It was found that the general design methods of stand-alone photovoltaic systems do not consider within the process to include the power consumption of the electrical protections, because the consumption of these compared to the consumption of the load is very low, however, for loads of low power and permanent use regime as considered in this project or similar, it is necessary to consider this consumption within the dimensioning process. In this design it was estimated that the losses associated exclusively with the electrical protections correspond to approximately 50% of the total losses of the system. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electricista | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/36698 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Eléctrica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Horas Pico Solares | |
dc.subject | Ideam | |
dc.subject | Mute | |
dc.subject | Nasa | |
dc.subject | Sistema Fotovoltaico En Dc Aislado. | |
dc.subject.keyword | Peak Sun Hours | |
dc.subject.keyword | Ideam | |
dc.subject.keyword | Mute | |
dc.subject.keyword | Nasa | |
dc.subject.keyword | Dc Stand-Alone Photovoltaic System. | |
dc.title | Diseño de un sistema fotovoltaico en DC aislado para alimentar el telescopio de muones (mute) desarrollado por el Grupo de Investigación en Relatividad y Gravitación (GIRG) | |
dc.title.english | Design of a dc stand-alone photovoltaic system for supplying de investigación en rela | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 782.35 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 231.87 KB
- Format:
- Adobe Portable Document Format