Sistema de adquisición automática de imágenes para microscopio óptico
dc.contributor.advisor | Silva Cruz, Edwin Alberto | |
dc.contributor.advisor | Duarte Gualdron, Cesar Antonio | |
dc.contributor.author | Pertuz Arroyo, Said David | |
dc.contributor.author | Ibanez Grandas, Hector Renee | |
dc.date.accessioned | 2024-03-03T16:33:26Z | |
dc.date.available | 2007 | |
dc.date.available | 2024-03-03T16:33:26Z | |
dc.date.created | 2007 | |
dc.date.issued | 2007 | |
dc.description.abstract | El presente documento contiene la descripción del desarrollo de un sistema que permite coordinar de manera autónoma desde PC los movimientos de la platina de un microcopio óptico en los ejes X, Y, y Z (enfoque), por medio de un conjunto de tres motores pasos a paso; el control se realiza empleando el puerto paralelo del computador. Acoplado al microscopio, se encuentra una cámara Web USB que envía las imágenes adquiridas al PC, para ser procesadas y determinar su grado relativo de enfoque por medio de técnicas basadas en tratamiento digital de imágenes. Éste sistema se elaboró pensando en desarrollar una herramienta que permita facilitar y agilizar el proceso de observación y adquisición de imágenes de microscopia óptica, en particular, imágenes de tejido humano. Para la determinación de las imágenes mejor enfocadas, se realizó el estudio, implementación y evaluación de varios algoritmos, los cuales incluyen modificaciones y propuestas propias; el resultado de éste proceso fue la selección de los algoritmos de mejor desempeño. Posteriormente se desarrolló el algoritmo de búsqueda; este algoritmo es el que permite reducir el número de movimientos en el eje Z (enfoque) para obtener la imagen de mejor enfoque. Como resultado final, después de algunos ajustes iniciales definidos por medio de una interfaz de usuario, el sistema inicia realizando los movimientos en el eje Z hasta lograr el punto de mejor enfoque. Posteriormente se realizan movimientos en los ejes X-Y para repetir el procedimiento en otras porciones de la muestra observada. El conjunto de imágenes adquiridas quedan a disposición del usuario para poder ser almacenadas de forma permanente. | |
dc.description.abstractenglish | In this document, the development of a system that allows driving from PC the movements of a microscope stage in the X, Y and Z (focus) axis is described. The movement of the stage is driven via stepper motors, through the PC parallel port. A USB Web Cam is coupled to the microscope that sends acquired images to the PC for processing and measuring their relative degree of focus, based on digital image processing. This system was made, thinking in the development of a tool that facilitate and agility the observation and acquisition process of optic microscopic images, particularly, human tissue images. For the determination of best focused images, the analysis, implementation and evaluation of several algorithms was made, which include modifications and own proposal algorithms; the selection of the best performance algorithms was the result of this process. Subsequently, the searching algorithm is developed; this algorithm allows reduce the movements in the Z axis (focus) to obtain the best focused image. As a final result, after the definition of some initial parameters by means of a user interface, the system starts doing the movement in the Z axis to focus the image and then, an X-Y movement takes place to repeat the focusing process in another portion of the sample. The acquired set of images is then available to the user for saving them permanently. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electrónico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/19778 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Electrónica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Microscopio óptico | |
dc.subject | Tratamiento digital de imágenes | |
dc.subject | Medida de enfoque | |
dc.subject | Autoenfoque | |
dc.subject | Algoritmo de búsqueda | |
dc.subject.keyword | Optic microscopy | |
dc.subject.keyword | Digital image processing | |
dc.subject.keyword | Focus measuring | |
dc.subject.keyword | Autofocusing | |
dc.subject.keyword | Searching algorithm | |
dc.title | Sistema de adquisición automática de imágenes para microscopio óptico | |
dc.title.english | Automatic image adquisition system for optic microcopy | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |