Estimación de la Succión Total en Muestras Compactadas de Materiales Granulares Marginales (4-5-6) Mediante la Técnica del Papel Filtro
dc.contributor.advisor | Jaimes Merchán, Vladimir Ernesto | |
dc.contributor.advisor | Álvarez Lugo, Allez Eduardo | |
dc.contributor.author | Parra Rondon, Alvaro Javier | |
dc.contributor.evaluator | Rondon, José Alberto | |
dc.contributor.evaluator | Del Toro Rodríguez, Wilfrido | |
dc.date.accessioned | 2024-05-15T21:29:43Z | |
dc.date.available | 2024-05-15T21:29:43Z | |
dc.date.created | 2024-05-14 | |
dc.date.embargoEnd | 2029-05-22 | |
dc.date.issued | 2024-05-14 | |
dc.description.abstract | El presente artículo contiene el análisis asociado al comportamiento hidráulico desde la perspectiva de la succión total de materiales granulares marginales de subbase (MGMs), denominados así por no cumplir con la normatividad INVIAS; esto con el fin de estudiar la influencia de la plasticidad en el comportamiento mecánico e hidráulico de los MGMs 4-5-6. Para este análisis se realiza el proceso de medición de succión total presente en muestras de desempeño compactadas en la humedad óptima, por medio de la técnica del papel filtro establecida por el INVIAS. Por otra parte, Se realizaron trayectorias de secado y humedecimiento para evaluar la curva de retención de agua en los MGMs 4-5-6. En estos procesos, se van verificando en el tiempo la evolución de la masa y dimensiones de manera que el contenido de agua y el grado de saturación se calculan progresivamente hasta alcanzar valores objetivo. Alcanzado un grado de saturación objetivo en secado o humedecimiento las muestras se aíslan del ambiente de laboratorio y se equilibran por 15 días. Transcurrido este tiempo, se realiza la determinación de la succión total y matricial. El análisis de resultados sugiere preliminarmente, que no existe una influencia contundente en el intervalo de grados de saturación entre el 30% y 70% de las variaciones del Índice de plasticidad (IP) estudiadas para las muestras con un porcentaje de finos constante del 21% sobre las curvas de retención de agua del suelo. Por otra parte, los valores del valor de entrada de aire de las curvas de retención están por encima de lo esperado para materiales convencionales sin plasticidad reportados en la literatura. | |
dc.description.abstractenglish | This article contains the analysis associated with the hydraulic behavior from the perspective of the total suction of subbase marginal granular materials (MGMs), so called because they do not comply with the INVIAS regulations; This was done in order to study the influence of plasticity on the mechanical and hydraulic behavior of 4-5-6 MGMs. For this analysis, the process of measuring the total suction present in performance samples compacted in the optimal humidity is carried out, by means of the filter paper technique established by INVIAS. On the other hand, drying and wetting trajectories were performed to evaluate the water retention curve in the 4-5-6 MGMs. In these processes, the evolution of the mass and dimensions are verified over time so that the water content and the degree of saturation are calculated progressively until target values are reached. Once a target degree of saturation is reached in drying or wetting, the samples are isolated from the laboratory environment and balanced for 15 days. After this time, the determination of total and matrix suction is carried out. The analysis of the results preliminarily suggests that there is no conclusive influence in the range of saturation degrees between 30% and 70% of the variations of the Plasticity Index (PI) studied for samples with a constant percentage of fines of 21% on the soil water retention curves. On the other hand, the values of the air inlet value of the retention curves are above what is expected for conventional materials without plasticity reported in the literature. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Civil | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/42384 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Civil | |
dc.publisher.school | Escuela de Ingenieria Civil | |
dc.rights | info:eu-repo/semantics/embargoedAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_f1cf | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Material granular marginal (MGM) | |
dc.subject | Índice de plasticidad (IP) | |
dc.subject | Succión total | |
dc.subject | Secado | |
dc.subject | Humedecimiento | |
dc.subject | Curva de retención de agua del suelo | |
dc.subject.keyword | Marginal Granular Material (MGM) | |
dc.subject.keyword | Plasticity Index (PI) | |
dc.subject.keyword | Total Suction | |
dc.subject.keyword | Drying | |
dc.subject.keyword | Wetting | |
dc.subject.keyword | Soil Water Retention Curve | |
dc.title | Estimación de la Succión Total en Muestras Compactadas de Materiales Granulares Marginales (4-5-6) Mediante la Técnica del Papel Filtro | |
dc.title.english | Estimation of Total Suction in Compacted Samples of Marginal Granular Materials (4-5-6) Using the Filter Paper Technique | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Carta de Autorizacion .pdf
- Size:
- 87.46 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta Confidencialidad.pdf
- Size:
- 97.96 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota del proyecto.pdf
- Size:
- 227.52 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Documento.pdf
- Size:
- 631.51 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: