Predicción de los Niveles de Glucosa en Sangre para Pacientes Diabeticos a Partir de Redes Neuronales Recurrentes Tipo LSTM

dc.contributor.advisorVillamizar Mejía, Rodolfo
dc.contributor.advisorRodríguez Moreno, Edward Alfonso
dc.contributor.authorVega Rojas, Ismael
dc.contributor.evaluatorFajardo Ariza, Carlos Augusto
dc.contributor.evaluatorRamirez Silva, Ana Beatriz
dc.date.accessioned2023-08-08T19:38:20Z
dc.date.available2023-08-08T19:38:20Z
dc.date.created2023-08-08
dc.date.issued2023-08-08
dc.description.abstractEn este trabajo de grado se presenta un modelo de estimación de glucosa para pacientes con diabetes mellitus tipo 1, donde se usa el simulador T1DMS (Visentin et al., 2018) con el que se obtiene un conjunto de mediciones de insulina y glucosa para entrenar el modelo de predicción. Para realizar este entrenamiento del modelo se utilizan series de tiempo, tomando como entrada valores pasados de glucosa en sangre e insulina inyectada y generando a la salida instantes de tiempo futuro de glucosa en sangre. Las secuencias de entrada constan de un conjunto de 15 muestras (timesteps) medidas cada minuto, mientras que la secuencia de salida, 210 muestras de glucosa futuras predichas mediante el modelo de estimación que corresponde a la curva completa de un episodio de glucosa después de una ingesta de glucosa por parte del paciente. Con estas secuencias de entradas y salidas se entrenan los modelos de Recurrent Neural Network (RNN) tipo LSTM, para 10 pacientes cada uno con un modelo personalizado, usando solo los episodios o curvas de glucosa de cada paciente en cada modelo. Y otro modelo generalizado, es decir usando los episodios o curvas de glucosa de todos los pacientes en un solo modelo. Para estimar el rendimiento del modelo, se usan las métricas de error MAE y RMSE, se evalúa el ajuste del modelo, se define la arquitectura final utilizando el número de capas y celdas que permitan una mejor precisión, al igual que el optimizador que mejor funcione, como los inicializadores adecuados, y las funciones de activación en cada capa del modelo, para que se obtengan las predicciones más exactas. Donde se toma como base lo aprendido en el curso electivo de Deep learning, dictado en el 2022-2, en la Universidad Industrial de Santander.
dc.description.abstractenglishIn this degree project, a glucose estimation model for patients with type 1 diabetes mellitus is presented, where the T1DMS simulator (Visentin et al., 2018) is used to obtain a set of insulin and glucose measurements to train the prediction model. To carry out this training of the model, time series are used, taking as input past values of blood glucose and injected insulin and generating instants of future time of blood glucose as output. The input sequences consist of a set of 15 samples (timesteps) measured every minute, while the output sequence consists of 210 future glucose samples predicted by the estimation model that corresponds to the complete curve of a glucose episode after a glucose intake by the patient. With these sequences of inputs and outputs, the LSTM-type Recurrent Neural Network (RNN) models are trained for 10 patients each with a personalized model, using only the episodes or glucose curves of each patient in each model. And another generalized model, that is, using the episodes or glucose curves of all the patients in a single model. To estimate the performance of the model, the MAE and RMSE error metrics are used, the fit of the model is evaluated, the final architecture is defined using the number of layers and cells that allow better precision, as well as the optimizer that works best. , such as the proper initializers, and activation functions at each model layer, so that the most accurate predictions are obtained. Where what was learned in the Deep learning elective course, taught in 2022-2, at the Industrial University of Santander.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Electrónico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/14745
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programIngeniería Electrónica
dc.publisher.schoolEscuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectGlucosa
dc.subjectPrediccion
dc.subjectDiabetes
dc.subjectRedes Neuronales
dc.subjectIn silico
dc.subjectUva Padova
dc.subject.keywordGlucose
dc.subject.keywordPrediction
dc.subject.keywordDiabetes
dc.subject.keywordNeural Networks
dc.subject.keywordIn silico
dc.subject.keywordUva Padova
dc.titlePredicción de los Niveles de Glucosa en Sangre para Pacientes Diabeticos a Partir de Redes Neuronales Recurrentes Tipo LSTM
dc.title.englishPrediction of Blood Glucose Levels for Diabetic Patients from LSTM-Type Recurrent Neural Networks
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Documento.pdf
Size:
687.67 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
130.96 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
251.46 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: