Efecto de la capacidad de disipación de energía seleccionada en el desempeño sísmico por desplazamiento de edificaciones con sistema muros de carga en zonas de sismicidad intermedia

dc.contributor.advisorSotelo Monroy, Fredy Saúl
dc.contributor.advisorBenjumea Royero, José Miguel
dc.contributor.authorUribe Hernández, Sandra Liliana
dc.contributor.evaluatorOsorio Bustamante, Edison
dc.contributor.evaluatorValencia Mina, William
dc.date.accessioned2022-04-01T04:04:19Z
dc.date.available2022-04-01T04:04:19Z
dc.date.created2021
dc.date.issued2021
dc.description.abstractEl reglamento colombiano de construcción sismo resistente (NSR-10) permite reducir las fuerzas sísmicas durante el diseño de edificaciones. Para esto se usa el coeficiente de disipación de energía (R), el cual depende del sistema de resistencia sísmica y la capacidad de disipación de energía esperada. La NSR-10 asocia un grado mínimo de capacidad de disipación de energía (mínima, moderada y especial) a cada zona de amenaza sísmica (baja, intermedia y alta, respectivamente).Esto deja abierta la posibilidad de usar un mayor grado de disipación al mínimo establecido en la norma para una determinada amenaza sísmica. Estudios previos han demostrado que el uso de un coeficiente de disipación de energía y requisitos detallados para capacidades superiores al grado mínimo en zonas de amenaza sísmica intermedia, puede resultar en la reducción de las cantidades de obra de la estructura; sin embargo, el efecto de este enfoque de diseño en el desempeño sísmico de la edificación no ha sido investigado. Por tal razón, en este trabajo se compara la capacidad de desplazamiento de una edificación de 15 pisos diseñados para una zona de amenaza sísmica intermedia con capacidades de disipación moderada y especial. El sistema estructural del edifico consiste en muros de concreto reforzado diseñado de acuerdo con las disposiciones del reglamento colombiano NSR-10. La edificación fue modelada mediante elementos finitos. La capacidad de desplazamiento para los casos moderado y especial se calcularon mediante un análisis no lineal estático siguiendo los requisitos de la guía ASCE / SEI 41-17. Entre los resultados encontrados se evidenció que la edificación con capacidad especial presentó una mayor capacidad de desplazamiento que la de capacidad moderada.
dc.description.abstractenglishThe Colombian Seismic Code (NSR-10) allows reducing seismic forces during the design of buildings. For this, the energy dissipation coefficient (R) is used, which depends on the seismic resistance system and the expected energy dissipation capacity. The NSR-10 associates a minimum seismic energy dissipation capacity (Ordinary, moderate and special) to each zone of seismic hazard (low, intermediate and high, respectively). This leaves open the possibility of using a higher degree of dissipation than the minimum established in the standard for a given seismic hazard. Previous studies have shown that the use of an energy dissipation coefficient and detailed requirements for capacities higher than the minimum seismic energy dissipation for a region with intermediate seismic hazard, can result in the reduction of the quantity of materials of the structure; however, the effect of this design approach on the building's seismic performance has not been investigated. For this reason, this work compares the displacement ductility capacity of a 15-stories building designed for an intermediate seismic hazard zone with moderate and special dissipation capabilities. The building's structural system consists of reinforced concrete walls designed in accordance with the provisions of the Colombian regulation NSR-10. The building was modeled by finite elements. The displacement capacity for the moderate and special cases were calculated using a static non-linear analysis following the requirements of the ASCE / SEI 41-17. Among the results found, it was evidenced that the building with special dissipation presented a greater displacement ductility capacity than the building with moderate dissipation.
dc.description.degreelevelMaestría
dc.description.degreenameMagíster en Ingeniería Estructural
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/9488
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programMaestría en Ingeniería Estructural
dc.publisher.schoolEscuela de Ingenieria Civil
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCapacidad de disipación de energía
dc.subjectCapacidad de desplazamiento
dc.subjectMuros de concreto
dc.subjectZona de amenaza sísmica
dc.subjectAnálisis no lineal estático
dc.subject.keywordEnergy Dissipation Capacity
dc.subject.keywordDisplacement Ductility Capacity
dc.subject.keywordRC Walls
dc.subject.keywordRegion Seismic Hazard
dc.subject.keywordNonlinear Static Analysis
dc.titleEfecto de la capacidad de disipación de energía seleccionada en el desempeño sísmico por desplazamiento de edificaciones con sistema muros de carga en zonas de sismicidad intermedia
dc.title.englishEffect of the select seismic energy dissipation capacity on displacement ductility capacity for buildings with shear wall system in a region with intermediate seismic hazard
dc.type.coarhttp://purl.org/coar/resource_type/c_bdcc
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Maestría
dspace.entity.type
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
180759_licence.pdf
Size:
134.93 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
180759_nota.pdf
Size:
488.38 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
180759_trabajo.pdf
Size:
22.51 MB
Format:
Adobe Portable Document Format