Comparación de la curva de capacidad de muros estructurales con diferentes relaciones de aspecto, diseñados utilizando el método tradicional y el método puntal-tensor
dc.contributor.advisor | Zapata Orduz, Luis Eduardo | |
dc.contributor.advisor | Cotes Prieto, David Sebastián | |
dc.contributor.author | Chávez Villamizar, Leonardo Enrique | |
dc.contributor.author | Gutiérrez Mantilla, Juan Pablo | |
dc.contributor.evaluator | Begambre Carrillo, Óscar Javier | |
dc.contributor.evaluator | Viviescas Jaimes, Álvaro | |
dc.date.accessioned | 2022-06-08T11:31:07Z | |
dc.date.available | 2022-06-08T11:31:07Z | |
dc.date.created | 2021 | |
dc.date.issued | 2021 | |
dc.description.abstract | Esta investigación compara la respuesta de 3 muros estructurales en concreto reforzado con diferentes valores de razón de aspecto (R.A), diseñados con los métodos: tradicional y Puntal-Tensor. Los diseños obtenidos se compararon con base en las propiedades mecánicas de cada elemento: ductilidad, tenacidad, resistencia, cantidad de acero a fluencia para una condición de deriva del 1%, y su estado de daño según el FEMA-356 a través de los diagramas Momento-Curvatura obtenidos mediante un análisis no lineal de carga incremental realizado con el software SAP2000vs.22. Al comparar los resultados de la curva de capacidad se infiere que los muros diseñados por el método Puntal-Tensor son más dúctiles con valores mayores al 59% respecto al método tradicional, mientras que los diseñados por el método Tradicional son más resistentes (con un rango de 21%-39%) y tenaces (superior a 1.2% para el caso de muro R.A=3.96 y mayores al 28% para demás casos), así pues, las mayores diferencias de los métodos se presentan en la capacidad de ductilidad llegando a valores hasta del 90.2% para muros de R.A=1.86, en tanto que, la menor diferencia se presenta en la deformación última y la razón demanda-capacidad de ductilidad con valores menores al 27% y 21.3% respectivamente. Asimismo, se infiere que los muros diseñados por el método Puntal-Tensor tienden a situarse en un estado de daño de prevención al colapso para las diferentes razones de aspecto, por otra parte, los muros diseñados usando el método tradicional se localizan en distintos rangos de estado de daño para sus diferentes razones de aspecto. En general se observa que los muros con R.A=3.96 presentan las diferencias más bajas en las categorías de: resistencia, tenacidad y volumen de aceros, siendo consecuente con su baja diferencia en volumen de acero, mientras que los muros con R.A=6.78 presentan las diferencias más bajas en las demás propiedades evaluadas: capacidad de ductilidad, deformación ultima y razón demanda-capacidad de ductilidad. | |
dc.description.abstractenglish | This research compares the response from 3 structural walls in reinforced concrete with different aspect ratios (A.R) each, designed with the methods: traditional and Strut and Tie, analyzing the mechanical properties of each element: ductility, toughness, strength, quantity of yielded steel for a 1% drift condition, and its damage state according to the FEMA-356, through the curves Moment-Curvature obtained from a non-linear incremental load analysis performed with the software SAP2000vs.22. When comparing the results of the capacity curve it is inferred that the walls designed by the Strut and Tie method are more ductile with values greater than 59.2% compared to the traditional method, while those designed by the Traditional method are more resistant (with a range between 21%-39%)-and tough (greater than1.2% for the walls with A.R=3.96 and greater than 28% for the other cases), thus, the greatest difference of the methods are presented in the ductility capacity reaching values up to 90.2% for walls with A.R=1.86, while, the least difference is presented in the ultimate deformation and the demand-capacity ratio of ductility with values lower than 27% and 21.3% respectively. Likewise, it is inferred that the walls designed by the Strut and Tie method tend to be in a state of collapse prevention damage for the different aspect ratios, on the other hand, the walls designed using the traditional method are in different ranges of damage state for each different aspect ratio. In general, it is observed that walls with A.R=3.96 present the lowest differences in the categories of: strength, toughness and steel volume, being consistent with their low difference in steel volume, while walls with R.A=6.78 present the lowest differences in the other evaluated properties: ductility capacity, ultimate deformation and ductility demand-capacity ratio. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Civil | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/11086 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Civil | |
dc.publisher.school | Escuela de Ingeniería Civil | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Muros de concreto reforzado | |
dc.subject | Razón de aspecto | |
dc.subject | Diseño tradicional | |
dc.subject | Diseño Puntal-Tensor | |
dc.subject | Diagrama Momento-Curvatura | |
dc.subject | Análisis no lineal | |
dc.subject | Curva de capacidad | |
dc.subject | Ductilidad | |
dc.subject | Tenacidad | |
dc.subject | Capacidad | |
dc.subject | Demanda | |
dc.subject | Estado de daño | |
dc.subject.keyword | Structural concrete walls | |
dc.subject.keyword | Aspect ratio | |
dc.subject.keyword | Traditional design | |
dc.subject.keyword | Strut and tie design | |
dc.subject.keyword | Curve Moment-Curvature | |
dc.subject.keyword | Non-linear analysis | |
dc.subject.keyword | Capacity curve | |
dc.subject.keyword | Damage state | |
dc.title | Comparación de la curva de capacidad de muros estructurales con diferentes relaciones de aspecto, diseñados utilizando el método tradicional y el método puntal-tensor | |
dc.title.english | Comparing the structural wall capacity curve with different aspect ratios, designed using the traditional method and strut-tensioner method | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |