Diseño a escala laboratorio de un sistema de tratamiento de aguas residuales contaminadas con residuos poliméricos

dc.contributor.advisorArenas Arenas, Adriana Isabel
dc.contributor.advisorCalderón Sarmiento, Hernán Camilo
dc.contributor.authorJiménez Mariño, Lady Tatiana
dc.contributor.authorMelo Ruiz, Jorge Milton
dc.date.accessioned2024-03-03T22:10:16Z
dc.date.available2015
dc.date.available2024-03-03T22:10:16Z
dc.date.created2015
dc.date.issued2015
dc.description.abstractLas aguas residuales generadas durante la etapa de producción y caracterización de materiales, en el laboratorio del Grupo de Investigación de Polímeros (GIP) de la Universidad Industrial de Santander, generan frecuentemente daños en la tubería de desagüe. Por tal razón fueron evaluadas mediante análisis fisicoquímicos tales como: pH, turbiedad, sólidos suspendidos totales (SST), grasas y aceites, y polímero disuelto. Los valores obtenidos se encuentran fuera de los rangos establecidos por la norma ambiental para el vertimiento de aguas residuales industriales al alcantarillado (resolución 0631 del 17 de Marzo de 2015). Como alternativa para el tratamiento de aguas residuales se usó la coagulación-floculación, probando tres coagulantes diferentes: Sulfato de Aluminio, Cloruro Férrico y Policloruro de Aluminio; siendo este último el único que consiguió mantener los valores de turbiedad y pH dentro de los límites establecidos, por lo tanto, presentó los mejores resultados y fue el coagulante seleccionado. Posteriormente, con base en las características del agua residual generada, se plantea el diseño de un sistema de tratamiento a escala laboratorio y se establecen las unidades de proceso necesarias para el mismo. Para comprobar la eficiencia del proceso se realizan pruebas con un volumen de 2 litros. Por último, se realizan los mismos análisis fisicoquímicos al agua tratada para garantizar que se cumple con los límites establecidos por la normatividad ambiental vigente, y al mismo tiempo, verificar la eficiencia del sistema
dc.description.abstractenglishThe wastewater generated during the production stage and characterization of materials in the laboratory of Grupo de Investigación en Polímeros (GIP) of the Universidad Industrial de Santander (UIS), commonly cause damage to the drain pipe. For this reason, it was evaluated by physical-chemical analysis such as: pH, turbidity, total suspended solids (TSS), fats and oils, and dissolved polymer. These values are outside the ranges established by the environmental standard for wastewater (resolution 0631 of March 17, 2015). As an alternative for treating wastewater coagulation-flocculation was used, testing three different coagulants: Ferric Chloride, Aluminum Sulfate and Polychloride of Aluminum; the latter being the only one who managed to keep the turbidity and pH values within established limits, therefore, it presented the best results and it was the selected coagulant. Subsequently, based on the characteristics of the wastewater generated, the design of a treatment system on laboratory scale and its respective process units are set. In order to check the efficiency of the process tests were conducted with a volume of 2 liters. Finally, the same physicochemical analyzes are performed to the treated water to ensure compliance with the established limits by current environmental regulations, and at the same time, check the efficiency of the proposed system.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/32988
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectAguas Residuales
dc.subjectPolímeros
dc.subjectCoagulante
dc.subjectSulfato De Aluminio
dc.subjectCloruro Férrico
dc.subjectPolicloruro De
dc.subject.keywordWastewater
dc.subject.keywordPolymers
dc.subject.keywordCoagulant
dc.subject.keywordAluminum Sulfate
dc.subject.keywordFerric Chloride
dc.subject.keywordPolychloride Of
dc.titleDiseño a escala laboratorio de un sistema de tratamiento de aguas residuales contaminadas con residuos poliméricos
dc.title.englishLaboratory scale design of a treatment system for wastewater contaminate with polymer
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
298.22 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
1.51 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
72.19 KB
Format:
Adobe Portable Document Format