Comparación de espectogramas de señales obtenidas mediante la técnica fed-sa sobre tejido mamario humano normal y anormal in-vivo

dc.contributor.advisorFernandez Pinto, Janeth
dc.contributor.advisorMiranda Mercado, David Alejandro
dc.contributor.authorMendoza Arias, Monica Andrea
dc.date.accessioned2024-03-04T00:15:57Z
dc.date.available2018
dc.date.available2024-03-04T00:15:57Z
dc.date.created2018
dc.date.issued2018
dc.description.abstractEl cáncer de mama solo se detecta en un estado avanzado, esto ocasiona que sea la principal causa de muerte por cáncer en mujeres en el mundo. Con el objetivo de disminuir las tasas de incidencia y mortalidad, en Colombia se emplea la mamografía. Sin embargo, esta no tiene el impacto que se requiere. En este trabajo se propone el uso de la técnica FED-SA para detectar anomalías bioquímicas relacionadas con el efecto de campo carcinogénico a través de un análisis espectral, con el cual se lograría detectar cambios desde los inicios del cáncer. Usando el dispositivo FED-SA, se iluminaron cuatro zonas de interés en cada mama, para 24 pacientes. Esta iluminación se hizo con luz láser en el infrarrojo cercano y durante 10 segundos se midió la luz retro-dispersada por el tejido. La toma de datos se realizó bajo el protocolo de medidas establecido por la técnica, el aval del comité de ética-CIENCI y el consentimiento de las pacientes. Para la cantidad de datos obtenidos, de intensidad en función del tiempo, se implementó un proceso para eliminar el ruido blanco, posteriormente se aplicó la transformada rápida de Fourier con dos ventanas de muestreo, 512 y 1024. Se construyeron 1152 espectrogramas, que corresponden a 48 espectrogramas por cada paciente. Para el análisis de los espectrogramas, los datos se ordenaron por ventana de muestreo, se establecieron en los espectrogramas rangos de frecuencias y se etiquetaron como anormal o normal de acuerdo a su historia clínica. Posteriormente se implementaron diagramas de caja y se realizó un análisis ANOVA. Dentro de los resultados obtenidos, se evidencian diferencias entre el tejido normal y anormal, en los cuadrantes: cuadrante inferior externo derecho e izquierdo, cuadrante superior externo derecho, cuadrante superior interno derecho, para los que se obtuvo un valor de p<0.05.
dc.description.abstractenglishBreast cancer is only detected at an advanced stage, what it causes to be the main cause of cancer death in women in the world. In order to reduce the incidence and mortality rates, mammography is used in Colombia. However, this does not have the impact that is required. In this project the use of the FED-SA technique is proposed to detect biochemical anomalies related to the field effect through a spectral analysis, which would detect changes from the beginning of cancer. By using the FED-SA device, four areas of interest were illuminated in each breast, for 24 patients. This illumination was done with laser light in the near infrared and for 10 seconds the light retro-dispersed by the tissue was measured. The data collection was made following the protocol of measures established by the technique, under the endorsement of the ethics committee of the Universidad Industrial de Santander and the According to the amount of obtained data, of intensity in function of time, a process was implemented to eliminate the white noise, later the fast Fourier transform was applied with two sampling windows, 512 and 1024. With the squared magnitude of FFT, they were built 1152 spectrograms, corresponding to 48 spectrograms for each patient. For the analysis of the spectrograms, the data was ordered by sampling window; frequency ranges were established in the spectrograms and were labeled as abnormal or normal according to their clinical history. Subsequently, box diagrams were implemented and an ANOVA analysis was carried out. Within the results obtained, there are differences between normal and abnormal tissue in the quadrants: left and right external lower quadrant, right external superior quadrant, right internal superior quadrant, for those the was obtained a value of p<0.05.
dc.description.degreelevelPregrado
dc.description.degreenameFísico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/39504
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ciencias
dc.publisher.programFísica
dc.publisher.schoolEscuela de Física
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectFed-Sa
dc.subjectCáncer De Mama
dc.subjectEfecto De Campo Carcinogénico
dc.subjectEspectrogramas
dc.subjectDiagrama De Cajas Y Bigotes
dc.subjectAnova.
dc.subject.keywordFed-Sa
dc.subject.keywordBreast Cancer
dc.subject.keywordCarcinogenic Field Effect
dc.subject.keywordSpectrograms
dc.subject.keywordBox-Plot
dc.subject.keywordAnova.
dc.titleComparación de espectogramas de señales obtenidas mediante la técnica fed-sa sobre tejido mamario humano normal y anormal in-vivo
dc.title.englishComparison of spectrograms of signals obtained by means of the fed-sa technique on normal and abnormal human breast tissue in-vivo.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
229.06 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
6.59 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
531.54 KB
Format:
Adobe Portable Document Format
Collections