Implementación de un montaje experimental para la técnica libs (laser induced breakdown spectroscopy) basado en el espectrómetro hr4000 de ocean optics
dc.contributor.advisor | Cabanzo Hernández, Rafael | |
dc.contributor.author | López Suarez, Ella Karina | |
dc.date.accessioned | 2024-03-03T16:13:19Z | |
dc.date.available | 2006 | |
dc.date.available | 2024-03-03T16:13:19Z | |
dc.date.created | 2006 | |
dc.date.issued | 2006 | |
dc.description.abstract | La técnica LIBS (Laser Induced Breakdown Spectroscopy - Espectro_x0002_scopía de Plasma Inducido por Láser), es un tipo de espectroscopía de emisión atómica, la cual utiliza como fuente de excitación un pulso láser de alta potencia. Para obtener la información espectral, el Laboratorio de Espectroscopía Atómica y Molecular (LEAM), de la Universidad Industrial de Santander, ha venido empleando los espectrómetros Jarrell-Ash, tipo Ebert (f = 3.4m) y DK480 tipo Czerny Turner (f = 0.5m) de Spectral Products, a los cuales se les ha implementado como sistema de detección una cámara CCD, la cual registra, en una adquisición, una región espectral de tamaño limitado; 12.5 y 35nm, respectivamente. El espectrómetro HR4000 de Ocean Optics, es un equipo muy compacto, de baja resolución y alta sensibilidad; por lo cual se desean identificar ventajas y limitaciones del equipo cuando se utiliza en la aplicación de la técnica LIBS. En este trabajo se presentan los resultados obtenidos cuando se realiza análisis cualita_x0002_tivo de muestras sólidas, tales como: Al, Cu, Pb, Zn, Caolín, Carbón y vidrio. Así mismo se presentan las limitaciones encontradas cuando se realiza análisis de muestras que son muy ricas en líneas espectrales, tales como: Fe, Ni, Acero y Pirita. Con el fin de agilizar el análisis cualitativo de muestras, se elaboró un algoritmo interac_x0002_tivo que permite realizar análisis de espectros adquiridos con el espectrómetro HR4000. Este algoritmo asiste al operario en la identificación de las líneas espectrales, de tal forma que es el operario quien en última instancia toma la decisión sobre la asignación de una línea espectral a un elemento atómico particular. Como el equipo posee conexiones para temporización de la adquisición del espectro, se implementó un sistema de retardo que permite controlar externamente el inicio del proceso de adquisición del espectro. | |
dc.description.abstractenglish | The technique LIBS (Laser Induced Breakdown Spectroscopy), itis a type of atomic emission spectroscopy, which uses as excitation source a high powerlaser pulse. To obtain the spectral information, the Laboratorio de Espectroscopia Atémica y Molecular (LEAM), of the Universidad Industrial de Santander has come employing thespectrometers Jarrell-Ash, type Ebert (f = 3.4m) and DK480 type Czerny Turner (f= 0.5m) of Spectral Products, to which have been implemented as detection systema camera CCD, which registers, in one acquisition, a spectral region of limited size;12.5 and 35nm, respectively. The HR4000 spectrometer of Ocean Optics is a very compact equipment, of low resolution and high sensibility; reason why we want to identifyadvantages and limitations of the equipment when it is used in the application of theLIBS technique . In this work we present the obtained results of realized qualitative analysis of suchsolid samples as: Al, Cu, Pb, Zn, kaolin, coal and glass. However we found several limitations when we realize analysis of samples as: Fe, Ni and Steel and Pyre. With the purpose of speeding up the qualitative analysis of samples, we elaboratedan interactive algorithm that allows carrying out analysis of acquired spectra with thespectrometer HR4000. This algorithm assists the operative in the identification of thespectral lines, in such a way that is the operative who ultimately takes the decision onthe assignment of a spectral line to a particular atomic element. As the equipment possesses connections for temporize the acquisition of the spectrum,we implemented a retard system that allows controlling externally the beginning of theprocess of acquisition of the spectrum. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Físico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/19094 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ciencias | |
dc.publisher.program | Física | |
dc.publisher.school | Escuela de Física | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | LIBS | |
dc.subject | Espectroscopía | |
dc.subject | Espectrómetro | |
dc.subject | Análisis cualitativo. | |
dc.subject.keyword | LIBS | |
dc.subject.keyword | Spectroscopy | |
dc.subject.keyword | Spectrometer | |
dc.subject.keyword | Qualitative analysis. | |
dc.title | Implementación de un montaje experimental para la técnica libs (laser induced breakdown spectroscopy) basado en el espectrómetro hr4000 de ocean optics | |
dc.title.english | Implementation of an experimental assembly for thetechnique libs (laser induced breakdown spectroscopy) basedon the spectrometer hr4000 of ocean optics | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |