dc.description.abstract | La energía solar fotovoltaica ha sobresalido en los últimos años aumentando exponencialmente a nivel mundial. Aunque se han considerado eficientes en condiciones de campo, existe un fenómeno que causa efectos adversos en los módulos, este se conoce como degradación inducida por potencial (PID), por tanto, se hace indispensable implementar una metodología que pueda detectar esta alteración previniendo así daños irreversibles que conlleven a un cambio prematuro del mismo. Con este trabajo de grado se buscó analizar diversos métodos para determinar la PID en paneles de silicio cristalino y seleccionar el más adecuado para implementarlo en la instalación solar fotovoltaica del Centro de Tecnología de la Manufactura Avanzada (CTMA) ubicado en Medellín - Colombia. El desarrollo de este proyecto comprendió cuatro capítulos; en el primero se ahondó acerca del fenómeno de la degradación inducida por potencial (PID), sus posibles causas y las repercusiones que tiene, posteriormente se modelaron las corrientes de fuga responsables de la PID y se correlacionaron la humedad, el voltaje, la temperatura y los materiales que componen la celda fotovoltaica con la aparición de corrientes de fuga que originan dicho fenómeno. En el segundo se abordaron las metodologías en-sitio encontradas en la literatura técnica disponible, consecuentemente se realizó un cuadro comparativo en donde se mostraron diferencias, similitudes, ventajas y desventajas entre ellas. En el tercero se presentaron aspectos relevantes referentes a la latitud, altitud y climatología de la Ciudad en donde está ubicado el sistema fotovoltaico, posteriormente se mostró la descripción del sistema y las especificaciones técnicas que lo componen. En el cuarto se estructuró un plan para establecer cuál de los métodos fue el apropiado para detectar la PID en los módulos fotovoltaicos instalados en CTMA con el fin de sugerir un análisis para verificar el estado de operación de los paneles. | |
dc.description.abstractenglish | Solar photovoltaic energy has excelled in recent years, increasing exponentially worldwide. Although they have been considered efficient in field conditions, there is a phenomenon that causes adverse effects on the modules, this is known as potential induced degradation (PID), therefore, it is essential to implement a methodology that can detect this alteration thus preventing irreversible damage leading to a premature change of the same. With this degree work we sought to analyze various methods to determine PID in crystalline silicon panels and select the most appropriate to implement it in the solar photovoltaic installation of the Center for Advanced Manufacturing Technology located in Medellin - Colombia. The development of this project consisted of four chapters; in the first one, the phenomenon of potential induced degradation (PID), its possible causes and repercussions were studied in depth, then the leakage currents responsible for PID were modeled and the humidity, voltage, temperature and the materials that compose the photovoltaic cell were correlated with the appearance of leakage currents that originate this phenomenon. In the second one, the in-situ methodologies found in the available technical literature were discussed, and consequently, a comparative table was made showing differences, similarities, advantages and disadvantages among them. In the third part, relevant aspects related to the latitude, altitude and climatology of the city where the photovoltaic system is located were presented, then the description of the system and its technical specifications were shown. In the fourth, a plan was structured to establish which of the methods was the appropriate one to detect PID in the photovoltaic modules installed in the center of technology and advanced manufacturing in order to suggest an analysis to verify the operating status of the panels. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electricista | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/11704 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Eléctrica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Corrientes de fuga | |
dc.subject | PID | |
dc.subject | Degradación inducida por potencial | |
dc.subject | Módulos fotovoltaicos | |
dc.subject.keyword | leakage currents | |
dc.subject.keyword | PID | |
dc.subject.keyword | Potential Induced Degradation | |
dc.subject.keyword | photovoltaic modules | |
dc.title | Métodos para determinar la degradación inducida por potencial en paneles fotovoltaicos | |
dc.title.english | Methods to determine potential-induced degradation in photovoltaic panels | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 5 of 7
No Thumbnail Available
- Name:
- Apéndice D.pdf
- Size:
- 1.66 MB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 149.77 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: