Análisis de los hábitos de uso del agua potable y su influencia sobre la producción y composición de las aguas grises claras generadas dentro de una vivienda residencial de Bucaramanga, caso de estudio: Barrio La Victoria

dc.contributor.advisorOcaña Oviedo, Édgar Ricardo
dc.contributor.advisorRey Romero, Daniela Cristina
dc.contributor.advisorBurgos Arias, Jessica Patricia
dc.contributor.authorFernández Acevedo, Lizeth Camila
dc.contributor.evaluatorParra Orobio, Brayan Alexis
dc.contributor.evaluatorPaz Soto, Jonathan
dc.date.accessioned2023-05-24T13:19:59Z
dc.date.available2023-05-24T13:19:59Z
dc.date.created2023-05-22
dc.date.issued2023-05-22
dc.description.abstractCon el fin de preservar el recurso hídrico, han surgido alternativas como la reutilización de aguas grises claras (AGC), sin embargo, a pesar de tener múltiples estudios sobre el tratamiento que requieren las AGC para poder ser reutilizadas, existe poca información sobre los factores que afectan su calidad y producción. Con el propósito de contribuir a reducir este vacío de información, esta investigación estudió los hábitos del uso del agua potable de la población del barrio La Victoria en la ciudad de Bucaramanga (Colombia) por medio de encuestas presenciales a 94 viviendas residenciales y analizó la producción y calidad de las AGC de una vivienda de dicho barrio por medio de jornadas de aforos y muestreos. Para determinar la calidad de las AGC se seleccionaron 5 parámetros fisicoquímicos: pH, turbidez, sólidos suspendidos totales (SST), demanda química de oxígeno (DQO) y demanda bioquímica de oxígeno (DBO5). Se registró que el 51% de las personas se bañan 2 veces al día y el 16% se lava las manos 5 veces al día. Se obtuvo un consumo promedio de AGC de 115 ± 33 [L/día], con un aporte promedio del 21.5 ± 0.06% respecto a las aguas residuales domésticas (ARD), el cual se dividió en 20% por duchas y 1.12% por lavamanos. Los parámetros SST (185.8 [mg/L]) y turbidez (223.9 ± 8.02 [NTU]) se vieron afectados por los aceites e intensificadores de espuma presentes en el champú y el jabón; el pH (7.5 ± 0.05) tuvo una leve tendencia alcalina por la presencia de sodio en el jabón corporal y los aumentos de DQO (769.5 ± 11.9 [mg/L]) y DBO5 (342.1 [mg/L]) se debe a ingredientes de origen orgánico que tienen productos de higiene personal como el champú.
dc.description.abstractenglishTo preserve the water resource, alternatives have emerged such as the reuse of light grey water (LGW), however, despite having multiple studies on the treatment that LGW requires to be reused, there is a few information on the factors affecting their quality and production. To help reduce this information gap, this research study studied the drinking water use habits of the population of the La Victoria neighborhood in the Bucaramanga city (Colombia) by means of face-to-face surveys of 94 residential dwellings and analyzed the production and quality of the LGW of a dwelling in that neighborhood by means of capacity days and sampling. Five physicochemical parameters were selected to determine the quality of the LGW: pH, turbidity, total suspended solids (TSS), chemical oxygen demand (COD) and biochemical oxygen demand (BOD5). It was recorded that 51% of people bathe twice a day and 16% wash their hands 5 times a day. We obtained an average consumption of AGC of 115 ± 33 [L/day], with an average contribution of 21.45 ± 0.06% compared to the domestic wastewater (DWW), which was divided into 20% by showers and 1.12% by sinks. TSS parameters (185.8 [mg/L]) and turbidity (223.9 ± 8.02 [NTU]) were affected by the foam oils and intensifiers present in shampoo and soap; pH (7.5 ± 0.05) had a slight alkaline tendency for the presence of sodium in body soap and increases in COD (769.5 ± 11.9 [mg/L]) and BOD5 (342.1 [mg/L]) are due to ingredients of organic origin that have personal hygiene products such as shampoo.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Civil
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/14327
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programIngeniería Civil
dc.publisher.schoolEscuela de Ingenieria Civil
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectAguas grises claras
dc.subjectParámetros fisicoquímicos
dc.subjectHábitos del uso del agua
dc.subject.keywordLight Grey Water
dc.subject.keywordPhysicochemical Parameters
dc.subject.keywordWater Use Habits
dc.titleAnálisis de los hábitos de uso del agua potable y su influencia sobre la producción y composición de las aguas grises claras generadas dentro de una vivienda residencial de Bucaramanga, caso de estudio: Barrio La Victoria
dc.title.englishAnalysis of Potable Water Use Habits and its Influence on the Production and Composition of Light Grey Water generated inside a Residential House in Bucaramanga, Case Study: La Victoria Neighborhood
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.type
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Documento.pdf
Size:
751.58 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
171.66 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
545.28 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: