Diseño y construccion de un prototipo funcional de protesis transfemoral con mecanismo de rodilla basado en mecanismo de bloqueo en llave "screw home mechanism"
dc.contributor.advisor | Villegas Bermúdez, Diego Fernando | |
dc.contributor.advisor | Lopez Gualdron, Clara Isabel | |
dc.contributor.author | Arciniegas Hernandez, Kevin Yesid | |
dc.contributor.author | Cala Cala, Astrid Carolina | |
dc.date.accessioned | 2023-04-06T04:21:47Z | |
dc.date.available | 2023 | |
dc.date.available | 2023-04-06T04:21:47Z | |
dc.date.created | 2019 | |
dc.date.issued | 2019 | |
dc.description.abstract | En este proyecto de investigación se desarrolló el diseño y construcción de un prototipo funcional de prótesis transfemoral, al cual se implementó con el fin de aportar al mercado una nueva alternativa, que además busca proporcionar al paciente mayor estabilidad y una marcha más natural. Se tiene como objetivos que el diseño sea de bajo costo, permitiendo así que se encuentre al alcance de personas que no cuenten con muchos recursos económicos, esto es posible implementando materiales que no sean tan costosos y que se encuentren fácilmente en el mercado; también se busca que sea de mínimo mantenimiento y que a su vez se pueda garantizar un funcionamiento óptimo. metodología permitió ordenar la información dividiéndola en fases, para así poder tener clara la estructura a seguir y obtener un desarrollo eficiente del proyecto. Por otra parte se realizó el diseño y simulación de la alternativa ganadora mediante SOLIDWORK, que facilito la construcción y análisis de los diferentes componentes, caracterizándolos según sus diferentes propiedades y permitiendo realizar correcciones en el modelo simplemente editando el croquis inicial, de tal manera que se ajustara al requerimiento del diseñador. A partir de ese diseño realizado en Solidworks se procedió a crear una impresión 3D para tener una idea palpable de la prótesis y poder validar su movilidad. Una vez obtenido el prototipo funcional, se procedió a tomar las pruebas de laboratorio, donde se realizó un análisis de marcha, de tal manera que se pudo verificar el funcionamiento y movilidad que ofrece la prótesis en comparación con las que ofrece actualmente el mercado. * | |
dc.description.abstractenglish | In this research project, the construction and design of a functional prototype of transfemoral prosthesis was developed, to which the "screw home" locking mechanism is implemented. This was in order to provide the market with a new alternative, which also seeks to provide the patient with greater stability and a more natural gait. The main objective is that the design should be low cost, allowing it to be available to people who do not have many economic resources, this is possible by implementing materials that are not so expensive and that are easily found in the market; It is also intended to be of minimum maintenance and in turn can ensure optimal performance. The project was developed using the methodology "NASA ESMD capstone Design", the methodology allowed to organize the information by dividing it into phases, in order to be clear about the structure to follow and obtain an efficient development of the project. On the other hand, the design and simulation of the winning alternative was carried out using SOLIDWORK, which facilitated the construction and analysis of the different components, characterizing them according to their different properties and allowing to make corrections in the model by simply editing the initial sketch, in a way that will adjust to the requirement of the designer. From that design made in Solidworks, we proceeded to create a 3D impression to have a tangible idea of the prosthesis and be able to validate its mobility. Once the functional prototype was obtained, we proceeded to take the laboratory tests, where a gait analysis was carried out, in a way that the functioning and mobility offered by the prosthesis could be verified in comparison with those currently offered by the market. * Draft Degree ** Faculty of Physical-Mechanical Engineering. School of Mechanical Engineering. Director Diego Fernando Villegas, Doctor in Mechanical Engineering. Co-director Clara Isabel López Gualdron, PhD in | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Mecánico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/13594 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Mecánica | |
dc.publisher.school | Escuela de Ingeniería Mecánica | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Prótesis Transfemoral | |
dc.subject | Screw Home | |
dc.subject | Biomecánica | |
dc.subject.keyword | Transfemoral Prosthesis | |
dc.subject.keyword | Screw Home | |
dc.subject.keyword | Biomechanics | |
dc.title | Diseño y construccion de un prototipo funcional de protesis transfemoral con mecanismo de rodilla basado en mecanismo de bloqueo en llave "screw home mechanism" | |
dc.title.english | Construction and design of a functional prototype of transfemoral prosthesis based on the knee mechan* | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 149.95 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 142.64 KB
- Format:
- Adobe Portable Document Format