Algoritmo computacional que permita caracterizar y analizar los parametros de la senal electrooculografica del movimiento sacadico en personas sanas del area metropolitana de bucaramanga
dc.contributor.advisor | Mendoza Castellanos, Alfonso | |
dc.contributor.author | Villar Torres, Julieta | |
dc.contributor.author | Saavedra Mejia, Ana Jimena Carolina | |
dc.date.accessioned | 2024-03-03T04:35:18Z | |
dc.date.available | 2004 | |
dc.date.available | 2024-03-03T04:35:18Z | |
dc.date.created | 2004 | |
dc.date.issued | 2004 | |
dc.description.abstract | Este trabajo describe un modelo matemático para caracterizar el comportamiento morfológico de la señal Electrooculográfica, en los dominios de tiempo y frecuencia, con el fundamento computacional de la transformada de Wavelet, ésta permitió el tratamiento y la estandarización de los siguientes parámetros electrofisiológicos: amplitud, velocidad de pico, duración y latencia. El proyecto de investigación contempló aspectos importantes como: la creación del montaje experimental para realizar la prueba de estimulación, captura y análisis de la señal, es decir, los criterios del Electrooculograma (EOG), test que registra los movimientos sacádicos oculares (los ojos llevan a cabo un desplazamiento en el plano horizontal). Dicho seguimiento programado requirió el diseño de un dispositivo (electroestimulador), al igual que el desarrollo del protocolo clínico para el muestreo de la población de estudio (110 pacientes), de acuerdo a la normatividad del especialista. Es apreciable en el software los hallazgos estadísticos de los parámetros. Así se estableció la plataforma para la proyección del estudio con posteriores trabajos de investigación clínica en alteraciones oculomotoras, donde el EOG es ampliamente aceptado como herramienta de complemento y apoyo en el diagnóstico oftalmológico. Es un estudio pionero en el país, por cuanto no existen referencias, constituyéndose en un método de bajo costo. | |
dc.description.abstractenglish | This study describes a mathematical model to characterize the morphological behaviour of the Electrooculography signal, in the domains of time and frequency, with the computational base of the Wavelet Transform. This allows the treatment and the standarization of the electrophysiologic parameters: Amplitude, Peak Velocity, Duration and latency. The research project contemplated important aspects such as: the creation of an experimental set-up to realize the stimulation test, capture and analysis of the signal. This means, the criteria for the Electrooculogram (EOG) test, registers the saccadic eye movements (the eyes make a shift in a horizontal plane). This scheduled follow-up requires a design of a device (electro-stimulator), as well as the development of the clinical protocol for sampling the population of the study (110 patient), according to the specialist standard. The statistics findings of the parameters are highlighted in the software. Thus, a platform was establish for the projection of the study and to conduct further clinical research in oculomotor pathology, where the EOG is widely accepted as a support tool in the ophthalmological diagnosis. This is a pioneer study in the country, since references do not exist, it constitutes a low cost method. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero de Sistemas | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/16043 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería de Sistemas | |
dc.publisher.school | Escuela de Ingeniería de Sistemas e Informática | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Electrooculografía | |
dc.subject | Wavelet | |
dc.subject | Sacádico | |
dc.subject.keyword | Electrooculography | |
dc.subject.keyword | Wavelet | |
dc.subject.keyword | Saccadic | |
dc.title | Algoritmo computacional que permita caracterizar y analizar los parametros de la senal electrooculografica del movimiento sacadico en personas sanas del area metropolitana de bucaramanga | |
dc.title.english | Standarization of parameters of the electrooculography signal of the saccadic movement in healthy people of the metropolitan area of bucaramanga | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |