Análisis radiómico multimodal con mamografía digital de campo completo e imágenes de seno basadas en ultrasonido
dc.contributor.advisor | Pertuz Arroyo, Said David | |
dc.contributor.advisor | Ramírez Silva, Ana Beatriz | |
dc.contributor.author | Vargas Molano, Andrés Felipe | |
dc.contributor.evaluator | Martínez Carrillo, Fabio | |
dc.contributor.evaluator | Miranda Mercado, David Alejandro | |
dc.date.accessioned | 2023-11-10T21:02:04Z | |
dc.date.available | 2023-11-10T21:02:04Z | |
dc.date.created | 2023-11-07 | |
dc.date.issued | 2023-11-07 | |
dc.description.abstract | La tomografía computarizada por ultrasonido es una nueva tecnología de imágenes actualmente investigada para la adquisición de imágenes médicas. Ha despertado interés porque es una técnica no invasiva que genera imágenes a partir de la propagación de ondas de ultrasonido a través del tejido, permitiendo así inferir propiedades del tejido de forma indolora y sin radiaciones ionizantes. Sin embargo, el estándar de oro para el cribado del cáncer de seno es la mamografía, a pesar de presentar algunas limitaciones como la alta tasa de falsos positivos y la exposicion a radiación. Aquí, investigamos si la combinación de características radiómicas de ambas modalidades de imágenes Tomografía computarizada por ultrasonido y mamografía puede mejorar el rendimiento en la detección de lesiones mamarias. Realizamos un ensayo in-silico para la detección de lesiones mamarias. Primero, construimos un conjunto de fantomas mamarios virtuales utilizando VICTRE: 58 fantomas con lesiones mamarias y 58 fantomas sin lesiones. Luego, simulamos la adquisición de imágenes de ultrasonido utilizando la técnica de inversión de forma de onda completa y la adquisición de imágenes mamográficas utilizando el software de simulación de imágenes de rayos X MCGPU. Posteriormente, extrajimos un conjunto de características radiómicas de ambas modalidades de imagen. Finalmente, se evaluó el rendimiento del análisis radiómico multimodal para la tarea de detección de lesiones en términos de AUC y se comparó con el uso de una sola modalidad de imagen. En general, la combinación de ambas modalidades mostró mejoras estadísticamente significativas con AUC de 0,88 (IC: 0,82-0,95) en comparación con el uso de una única modalidad de imagen, con AUC de 0,77 (IC: 0,68-0,86) y 0,81 (IC: 0,73-0,89) para mamografía y tomografía computarizada por ultrasonido, respectivamente. La tomografía computarizada por ultrasonido basada en inversión de onda completa mejoró la detección de lesiones mamarias en combinación con la mamografía. | |
dc.description.abstractenglish | Ultrasound computed tomography (USCT) is a new imaging technology currently investigated for the acquisition of medical images. It has drawn a lot of interest because it is a non invasive technique that generates images based on the propagation of ultrasound waves through the tissue, thus allowing to infer tissue properties painlessly and without ionizing radiation. However, the gold standard for breast cancer screening is mammography, despite presenting some limitations such as the high rate of false positives and the fact that the patient must undergo radiation. Here, we investigated whether the combination of radiomic features from both USCT imaging modalities and full-field digital mammography (FFDM) can improve performance in detecting breast lesions. We carried out an in-silico trial for breast lesion detection. First, we constructed a set of virtual breast phantoms (VBPs) using VICTRE (United States Food and Drugs Administration): 58 VBPs with breast lesions and 58 VBPs without lesions. Then, we simulated ultrasound image acquisition using the Full-Waveform Inversion technique, and mammographic image acquisition using the MCGPU X-ray imaging simulation software. Subsequently, we extracted a set of radiomic features from both imaging modalities. Finally, the performance of multimodal radiomic analysis for the lesion detection task in terms of AUC was evaluated and compared against using only one imaging modality. Overall, the combination of both modalities showed statistically significant improvements with AUC of 0.88 (CI: 0.82-0.95) compared to using a single imaging modality, with AUCs of 0.77 (CI: 0.68-0.86) and 0.81 (CI: 0.73-0.89) for mammography and USCT, respectively. FWI-based USCT improved the detection of breast lesions in combination with mammography. | |
dc.description.cvlac | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001784029 | |
dc.description.degreelevel | Maestría | |
dc.description.degreename | Magíster en Ingeniería Electrónica | |
dc.description.orcid | https://orcid.org/0000-0001-9828-4248 | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/15274 | |
dc.language.iso | eng | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Maestría en Ingeniería Electrónica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Análisis radiómico | |
dc.subject | Cáncer de seno | |
dc.subject | Análisis multimodal | |
dc.subject | Ultrasonido | |
dc.subject | Mamografía | |
dc.subject.keyword | Radiomic Analysis | |
dc.subject.keyword | Breast Cancer | |
dc.subject.keyword | Multimodal Analysis | |
dc.subject.keyword | Ultrasound | |
dc.subject.keyword | Mammography | |
dc.title | Análisis radiómico multimodal con mamografía digital de campo completo e imágenes de seno basadas en ultrasonido | |
dc.title.english | Multimodal Radiomic Analysis with Full-Field Digital Mammography and Ultrasound-Based Breast Imaging | |
dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Maestría |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 142.45 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 299.53 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: