Comparación de la rigidez y deformación del cartílago articular medidas a compresión en temperatura ambiente y temperatura controlada corporal.

dc.contributor.advisorVillegas Bermúdez, Diego Fernando
dc.contributor.authorCastaño Muñoz, Victor Manuel
dc.contributor.authorRiaño Ardila, Jose Alberto
dc.contributor.evaluatorPertuz Comas, Alberto David
dc.contributor.evaluatorDiaz Guerrero, Pedro Jose
dc.date.accessioned2025-09-02T11:54:35Z
dc.date.available2025-09-02T11:54:35Z
dc.date.created2025-08-20
dc.date.issued2025-08-20
dc.description.abstractEl cartílago articular es un tejido vital para la biomecánica del cuerpo, amortiguando cargas y facilitando el movimiento en las articulaciones. Su degeneración, principal causa de la osteoartritis que afecta a millones de personas, subraya la importancia de caracterizar sus propiedades mecánicas. Sin embargo, la falta de estandarización en los ensayos ha dificultado la comparación de estudios. Ante este desafío, este proyecto se enfoca en un factor crítico: la temperatura de ensayo, un aspecto que a menudo se pasa por alto pero que es fundamental para simular condiciones fisiológicas. El estudio se propuso evaluar la rigidez del cartílago bovino en dos escenarios: a temperatura ambiente (23 °C) y a una temperatura corporal controlada (37 °C). Para ello, se empleó un método de indentación instrumentada con un indentador esférico de 1.5875 mm, siguiendo las condiciones críticas de un ensayo estandarizado. A través del modelo elástico de Hayes et al., se calculó el módulo elástico del cartílago, una medida clave de su rigidez. Los resultados experimentales mostraron una clara dependencia de la temperatura en las propiedades mecánicas del cartílago. Los valores del módulo elástico calculados a temperatura ambiente fueron consistentemente mayores que los obtenidos a temperatura corporal. Esta diferencia se confirmó como estadísticamente significativa mediante la prueba de Wilcoxon de rangos con signo para muestras pareadas (p=0.05), lo que demuestra que la temperatura tiene un impacto relevante en el comportamiento biomecánico del tejido. En conclusión, este trabajo resalta la sensibilidad del cartílago a la temperatura, estableciendo que los ensayos de caracterización mecánica deben realizarse bajo condiciones controladas que se asemejen al ambiente fisiológico. Esta investigación contribuye a la estandarización de los ensayos y proporciona información valiosa para una comprensión más precisa de las propiedades mecánicas del cartílago, lo cual es crucial para el diagnóstico y el desarrollo de terapias para afecciones como la osteoartritis.
dc.description.abstractenglishArticular cartilage is a vital tissue for body biomechanics, as it cushions loads and facilitates movement in joints. Its degeneration, the primary cause of osteoarthritis affecting millions of people, underscores the importance of characterizing its mechanical properties. However, the lack of standardization in testing has made it difficult to compare studies. Facing this challenge, this project focuses on a critical factor: the testing temperature, an often-overlooked aspect that is fundamental for simulating physiological conditions. This study aimed to evaluate the stiffness of bovine cartilage in two scenarios: at room temperature (23 °C) and at a controlled body temperature (37 °C). For this, an instrumented indentation method with a 1.5875 mm spherical indenter was used, following the critical conditions of a standardized test. Through the elastic model of Hayes et al., the cartilage’s elastic modulus, a key measure of its stiffness, was calculated. The experimental results showed a clear dependence of the mechanical properties of the cartilage on temperature. The calculated elastic modulus values at room temperature were consistently higher than those obtained at body temperature. This difference was confirmed to be statistically significant using the Wilcoxon signed-rank test for paired samples (p=0.05), demonstrating that temperature has a relevant impact on the tissue’s biomechanical behavior. In conclusion, this work highlights the sensitivity of cartilage to temperature, establishing that mechanical characterization tests must be performed under controlled conditions that resemble the physiological environment. This research contributes to the standardization of tests and provides valuable information for a more accurate understanding of the mechanical properties of cartilage, which is crucial for the diagnosis and development of therapies for conditions such as osteoarthritis
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Mecánico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/46126
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programIngeniería Mecánica
dc.publisher.schoolEscuela de Ingeniería Mecánica
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCartílago articular
dc.subjectBiomecánica
dc.subjectIndentación
dc.subjectRigidez
dc.subjectModulo elástico
dc.subjectTemperatura
dc.subjectViscoelástico
dc.subject.keywordArticular cartilage
dc.subject.keywordBiomechanics
dc.subject.keywordIndentation
dc.subject.keywordstiffness
dc.subject.keywordElastic module
dc.subject.keywordTemperature
dc.subject.keywordViscoelastic
dc.titleComparación de la rigidez y deformación del cartílago articular medidas a compresión en temperatura ambiente y temperatura controlada corporal.
dc.title.englishComparison of the stiffness and deformation of articular cartilage measured under compression at room temperature and controlled body temperature.
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Nota de Proyecto.pdf
Size:
221.78 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de Autorización .pdf
Size:
186.76 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
3.42 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: