Alta Integración de Fuentes de Energía Renovable en Sistemas Eléctricos: Capacidad de Operación ante Fallas de Corta Duración
dc.contributor.advisor | Petit Suarez, Johann Farith | |
dc.contributor.advisor | Mantilla Villalobos, María Alejandra | |
dc.contributor.author | Nova Ardila, Alex David | |
dc.contributor.author | Rodríguez Tovar, Erick Davey | |
dc.contributor.author | Rueda García, Leonel Gerardo | |
dc.contributor.authorcontact | aldanoar98@gmail.com | |
dc.contributor.evaluator | Soto Rios, Edison Andres | |
dc.contributor.evaluator | Osorio Silva, Fausto | |
dc.date.accessioned | 2024-10-28T20:32:48Z | |
dc.date.available | 2024-10-28T20:32:48Z | |
dc.date.created | 2024-10-27 | |
dc.date.issued | 2024-10-27 | |
dc.description.abstract | La creciente integración de fuentes de energía renovable en el sistema eléctrico ofrece importantes beneficios, como la reducción de emisiones de gases de efecto invernadero, la menor dependencia de combustibles fósiles y la estabilización de los precios del suministro energético. No obstante, para asegurar su correcta integración y operación continua, especialmente durante situaciones de falla, es fundamental desarrollar estrategias de control adecuadas. Este trabajo analiza la integración de fuentes de generación de energías renovables, particularmente plantas basadas en inversores, dentro del sistema eléctrico y su comportamiento ante fallas de corta duración. Se definen y clasifican las fallas de corta duración según diferentes estándares internacionales y posteriormente se presentan los requisitos de conexión, capacidades de operación y funcionalidades de soporte que los generadores deben cumplir para alinearse con los requerimientos de los códigos de red en diferentes países. Se identifican requerimientos clave como el cumplimiento de las curvas de soportabilidad de tensión HVRT y LVRT, el control dinámico de tensión mediante la inyección de corriente, Asimismo, se subraya la importancia del diseño de algoritmos de control en los lazos de los inversores conectados a la red, tales como los algoritmos de sincronización, controladores de corriente y generación de la referencia, con especial énfasis en estos últimos. | |
dc.description.abstractenglish | The growing integration of renewable energy resources into the electrical system offers important benefits, such as the reduction of greenhouse gas emissions, reduced dependence on fossil fuels and stabilization of energy supply prices. However, to ensure their correct integration and continuous operation, especially during fault situations, it is essential to develop adequate control strategies. This paper analyzes the integration of renewable energy resources, particularly inverter-based generators, into the electrical system and their behavior in the event of short duration faults. Short-duration faults are defined and classified according to different international standards and then the connection requirements, operation capabilities and support functionalities that generators must meet to align with grid code requirements in different countries are presented. Key requirements such as compliance with HVRT and LVRT voltage withstand curves, dynamic voltage control by current injection, dynamic voltage control by current injection, and the importance of the design of control algorithms in grid-connected inverter loops, such as synchronization algorithms, current controllers and reference generation, are identified, with special emphasis on the last ones. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electricista | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/44405 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Eléctrica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Energías renovables | |
dc.subject | Inversor de potencia | |
dc.subject | Fallas eléctricas | |
dc.subject | Control de tensión | |
dc.subject.keyword | Renewable energies | |
dc.subject.keyword | Power inverter | |
dc.subject.keyword | Electrical faults | |
dc.subject.keyword | Voltage control | |
dc.title | Alta Integración de Fuentes de Energía Renovable en Sistemas Eléctricos: Capacidad de Operación ante Fallas de Corta Duración | |
dc.title.english | High Integration of Renewable Energy Resources in Electric Systems: Operation Capability During Short Duration Faults | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 124.31 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 274.29 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Apéndice.pdf
- Size:
- 371.81 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: