Análisis Energético, Exergético y Ambiental de un Sistema de Refrigeración Booster con R744 (CO2) Basado en Eyector con Recuperación de Calor Interna Integrado con un Sistema Rankine Orgánico para Cadenas de Supermercados
dc.contributor.advisor | Amaris Castilla, Carlos Fidel | |
dc.contributor.author | Mora Roa, Sergio Felipe | |
dc.contributor.author | Dominguez Garcia, Diego Alejandro | |
dc.contributor.evaluator | Silva Ortiz, Pablo Andres | |
dc.contributor.evaluator | Rueda Ordoñez, Yesid Javier | |
dc.date.accessioned | 2025-09-04T16:05:49Z | |
dc.date.available | 2025-09-04T16:05:49Z | |
dc.date.created | 2025-08-30 | |
dc.date.issued | 2025-08-30 | |
dc.description.abstract | La creciente presión legislativa para mitigar el cambio climático ha promovido la adopción de tecnologías de refrigeración más sostenibles, como los sistemas basados en CO₂ (R-744). La investigación de estas soluciones resulta esencial para reducir el impacto ambiental del sector, mejorar la eficiencia energética y avanzar hacia una economía circular. En este estudio, se evalúa el rendimiento energético, exergético y ambiental de un sistema de refrigeración tipo booster con CO₂ (R-744), basado en eyector e integrado con un ciclo Rankine orgánico. El análisis se realiza considerando condiciones climáticas de Bucaramanga y una capacidad de enfriamiento total de 80 kW. Para ello, se desarrollaron modelos termodinámicos detallados para dos configuraciones: una que integra el ciclo Rankine orgánico con recuperación de calor interna (REF+ORC) y otra correspondiente al sistema booster basado en eyector, sin dicha integración (SOLO REF). El análisis comparativo muestra que el sistema con integración ORC presenta un mejor desempeño global a temperaturas inferiores a 25 °C, lo que lo hace inviable para Bucaramanga, pero adecuado para ciudades con climas más fríos. La incorporación de un eyector de alta efectividad representa un incremento de 22.3% en el rendimiento global del sistema (COP) debido a que reduce el consumo del compresor de media temperatura, sin afectar la cogeneración del ORC. Aunque la integración del ORC implica ciertos consumos auxiliares, el análisis exergético evidenció una mayor efectividad global del sistema al reducir pérdidas irreversibles. En el análisis ambiental no se evidencian diferencias significativas (<1%) entre los resultados del TEWI y del LCCP. Esto se debe a que la mayor parte de las emisiones del sistema se generan durante la fase operativa, mientras que las emisiones embebidas incluidas en el LCCP representan una fracción mínima del total. En consecuencia, el TEWI se consolida como una métrica suficiente y representativa para evaluar el desempeño ambiental del sistema. | |
dc.description.abstractenglish | The growing legislative pressure to mitigate climate change has encouraged the adoption of more sustainable refrigeration technologies, such as CO₂ (R-744)-based systems. Research on these solutions is essential to reducing the environmental impact of the sector, improving energy efficiency, and advancing toward a circular economy. In this study, the energy, exergy, and environmental performance of a CO₂ (R-744) booster refrigeration system, based on an ejector and integrated with an Organic Rankine Cycle (ORC), is evaluated. The analysis is conducted under the climatic conditions of Bucaramanga, with a total cooling capacity of 80 kW. To this end, detailed thermodynamic models were developed for two configurations: one integrating the Organic Rankine Cycle with internal heat recovery (REF+ORC), and another corresponding to the ejector-based booster system without such integration (REF ONLY). The comparative analysis shows that the ORC-integrated system performs better at ambient temperatures below 25 °C, making it unfeasible for Bucaramanga but suitable for cities with colder climates. The incorporation of a high-effectiveness ejector represents a 22.3% increase in the overall system performance (COP), as it reduces the medium-temperature compressor consumption without affecting ORC cogeneration. Although ORC integration involves certain auxiliary consumptions, the exergy analysis revealed greater overall system effectiveness by reducing irreversible losses. The environmental assessment did not show significant differences (<1%) between the TEWI and LCCP results. This is explained by the fact that most system-related emissions occur during the operational phase, while the embedded emissions included in the LCCP account for only a minimal fraction of the total. Consequently, TEWI is consolidated as a sufficient and representative metric for assessing the environmental performance of the system. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Mecánico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/46182 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Mecánica | |
dc.publisher.school | Escuela de Ingeniería Mecánica | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Eyector | |
dc.subject | Sistema de refrigeración tipo Booster | |
dc.subject | Ciclo Rankine orgánico | |
dc.subject | Dióxido de carbono | |
dc.subject | Impacto ambiental | |
dc.subject.keyword | Booster refrigeration system | |
dc.subject.keyword | Ejector | |
dc.subject.keyword | Organic Rankine cycle | |
dc.subject.keyword | Carbon dioxide | |
dc.subject.keyword | Environmental impact | |
dc.title | Análisis Energético, Exergético y Ambiental de un Sistema de Refrigeración Booster con R744 (CO2) Basado en Eyector con Recuperación de Calor Interna Integrado con un Sistema Rankine Orgánico para Cadenas de Supermercados | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 354.93 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de Autorizacion .pdf
- Size:
- 153.63 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de Autorización.pdf
- Size:
- 153.17 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: