Validacion clinica de un diagnostico de enfermeria en neonatologia : patron respiratorio ineficaz
dc.contributor.advisor | Orozco, Luis Carlos | |
dc.contributor.author | Rivera Parra, Maria Del Pilar | |
dc.date.accessioned | 2024-03-03T04:45:23Z | |
dc.date.available | 2004 | |
dc.date.available | 2024-03-03T04:45:23Z | |
dc.date.created | 2004 | |
dc.date.issued | 2004 | |
dc.description.abstract | La validación clínica de un diagnóstico de enfermería, es de vital importancia, por que brinda una base conceptual a los diagnósticos y mide la intensidad con la que éstos reflejan realmente las respuestas del paciente. Se aplicó el método de Fehring para la validación clínica. Dos enfermeras expertas valoraron simultáneamente la presencia o ausencia de las características definitorias: movimiento torácico asincrónico, frecuencia respiratoria aumentada, respiración con labios fruncidos, alteración en la relación I/E, uso de músculos accesorios; se adicionó alteración en la pulsoximetría. La muestra la constituyó recién nacidos ingresados en la unidad de neonatología de la Clínica Materno Infantil San Luis. Se aplicó la formula de Fehring en donde razones mayores o iguales de 0.8 correspondían a características definitorias tentativamente mayores; razones mayores de 0.5 y menores de 0.79 se catalogaron como características tentativamente menores. Se concluyó que en recién nacidos la única característica tentativamente mayor fue el uso de músculos accesorios (0.89); tentativamente menores : frecuencia respiratoria aumentada (0.6 ), alteración en el coeficiente I/E( 0.65 ).No indicativas del diagnóstico: respiración con labios fruncidos ( 0.077 ) y alteraciones en la pulsoximetría (0.5 ). la característica definitoria aleteo nasal , no se analizó aparte como tal, si no que durante el proceso de evaluación clínica de las expertas, la analizaron como parte de la evaluación del Silverman en la característica uso de músculos accesorios para respirar; lo cual debe ser corregido en futuras investigaciones porque es una característica definitoria aparte. | |
dc.description.abstractenglish | The clinical validation of an infirmary diagnosis, is of vital importance for that it offers a conceptual base to the diagnoses and it measures the intensity with which these really reflect the patient's answers. The method of Fehring was applied for the clinical validation. Two expert nurses valued the presence or absence of the characteristic definitorias simultaneously: asynchronous thoracic movement, increased breathing frequency, breathing with puckered lips, alteration in the relationship I/E, use of accessory muscles; alteration was added in the pulsoximetría. The sample constituted it newly born entered in the unit of neonatología of the Infantile Maternal Clinic San Luis. It was applied the it formulates of Fehring where you reason bigger or similar of 0.8 they corresponded tentatively to characteristic definitorias bigger; reason bigger than 0.5 and smaller than 0.79 they were classified tentatively as characteristic smaller. You concluded that in newly born the only characteristic tentatively bigger it was the one use of accessory muscles (0.89); tentatively smaller: increased breathing frequency (0.6), alteration in the coefficient I/E (0.65). Not indicative of the diagnosis: breathing with puckered lips (0.077) and alterations in the pulsoximetría (0.5). the characteristic definitoria nasal flapping, was not analyzed separated as such, if not that during the process of the experts' clinical evaluation, they analyzed it like part of the evaluation of the Silverman in the characteristic use of accessory muscles to breathe; that which should | |
dc.description.degreelevel | Especialización | |
dc.description.degreename | Especialista en Atención de Enfermería de Cuidado Crítico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/16936 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Salud | |
dc.publisher.program | Especialización en Atención de Enfermería en Cuidados Críticos | |
dc.publisher.school | Escuela de Enfermería | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Validación clínica | |
dc.subject | Diagnóstico de Enfermería | |
dc.subject | Método de | |
dc.subject.keyword | Clinical validation | |
dc.subject.keyword | Diagnostic of Infirmary | |
dc.subject.keyword | Method of | |
dc.title | Validacion clinica de un diagnostico de enfermeria en neonatologia : patron respiratorio ineficaz | |
dc.title.english | Clinical validation of an i diagnose of infirmary: ineffective breathing pattern | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |