Dimensionamiento de un sistema fotovoltaico conectado a la red para un usuario regulado caso AGPE
dc.contributor.advisor | Osma Pinto, Germán Alfonso | |
dc.contributor.author | Páez Alarcón, Brayan Ferney | |
dc.contributor.author | Castellanos Calvache, Érika Nathalia | |
dc.contributor.evaluator | Jiménez Vargas, Iván Edgardo | |
dc.contributor.evaluator | Rodríguez Velásquez, Rusber Octavio | |
dc.date.accessioned | 2022-04-22T15:45:55Z | |
dc.date.available | 2022-04-22T15:45:55Z | |
dc.date.created | 2022-04-22 | |
dc.date.issued | 2022-04-22 | |
dc.description.abstract | Este trabajo de grado se basa en el dimensionamiento de un sistema fotovoltaico conectado a la red para el hotel Arizona ubicado en Puerto Araujo, Santander. Se realiza la consulta de las condiciones ambientales de irradiancia, temperatura y velocidad del viento, en las fuentes de información establecidas. Y se determina el consumo eléctrico con la factura de energía. Se hace la consulta de las disposiciones legales, regulatorias y reglamentarias vigentes en Colombia y se identifican las aplicables para este proyecto. A partir de la información recolectada se realizan los cálculos matemáticos y se obtienen los datos de potencia fotovoltaica, capacidad del inversor, numero de paneles, entre otros. Además, se realiza la simulación del dimensionado en el software de PVsyst. Posteriormente, se desarrolla un análisis técnico-financiero basado en las curvas de generación hora a hora, éstas se proyectan para los 25 años de vida útil del sistema y se determina si el usuario entrega excedentes al operador de red permitiendo crédito de energía según lo establece la Resolución CREG 174 de 2021. Se realiza el cálculo de los ingresos y los egresos para realizar el flujo de caja durante la vida útil del sistema y se evalúa el valor actual neto, la tasa interna de retorno y el PAYBACK, para determinar la viabilidad del sistema. | |
dc.description.abstractenglish | This degree work is based on the dimensioning of a photovoltaic system connected to the network for the Arizona hotel located in Puerto Araujo, Santander. The environmental conditions of irradiance, temperature and wind speed are consulted in the established information sources. And the electricity consumption is determined with the energy bill. The legal, regulatory and regulatory provisions in force in Colombia are consulted and those applicable to this project are identified. From the information collected, mathematical calculations are made and data on photovoltaic power, inverter capacity, number of panels, among others, are obtained. In addition, the dimensioning simulation is performed in the PVsyst software. Subsequently, a technical-financial analysis is developed based on the generation curves hour by hour, these are projected for the 25-year useful life of the system and it is determined if the user delivers surpluses to the network operator, allowing energy credit as established. CREG resolution 174 of 2021. The calculation of income and expenses is carried out to realize the cash flow during the useful life of the system and the net present value, the internal rate of return and the PAYBACK are evaluated, to determine the viability of the system. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electricista | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/10147 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Eléctrica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Autogenerador | |
dc.subject | Sistema fotovoltaico | |
dc.subject | Análisis técnico-financiero | |
dc.subject.keyword | Autogenerator | |
dc.subject.keyword | Photovoltaic system | |
dc.subject.keyword | Technical-financial analysis | |
dc.title | Dimensionamiento de un sistema fotovoltaico conectado a la red para un usuario regulado caso AGPE | |
dc.title.english | Sizing of a Photovoltaic System Connected to the Grid for a User AGPE Regulated Case | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 344.19 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 232.68 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: