ALGORITMO PARA LA MEDICIÓN AUTOMÁTICA DE LA LONGITUD CERVICAL A PARTIR DE IMÁGENES DE ULTRASONIDO TRANSVAGINAL
dc.contributor.advisor | Cancino Rey, William Andres | |
dc.contributor.advisor | Pertuz Arroyo, Said David | |
dc.contributor.author | Valenzuela Sánchez, María Fernanda | |
dc.contributor.evaluator | Cabeza Gutiérrez, Natalia Johana | |
dc.contributor.evaluator | Rodríguez Ferreira, Julián Gustavo | |
dc.date.accessioned | 2025-05-21T18:13:48Z | |
dc.date.available | 2025-05-21T18:13:48Z | |
dc.date.created | 2025-05-20 | |
dc.date.issued | 2025-05-20 | |
dc.description.abstract | El parto prematuro (PP) es un importante problema de salud pública a nivel mundial, que afecta aproximadamente a 15 millones de embarazos cada año. Uno de los indicadores más fiables del riesgo de PP es la longitud cervical (LC), la cual se mide manualmente en imágenes de ecografía transvaginal (ETV). Sin embargo, las mediciones manuales están sujetas a variabilidad entre operadores, lo que limita su fiabilidad. Para mejorar la consistencia y la automatización, este estudio propone un enfoque basado en aprendizaje profundo para la evaluaci ´on de la LC. Se desarrolló un modelo basado en redes neuronales convolucionales (CNN) para detectar las posiciones de los calibradores y estimar la LC. Para lograr esto, primero se segmentó el tercio medio del cuello uterino en imágenes ETV del primer trimestre utilizando una red U-Net. Estas segmentaciones se usaron luego para entrenar el modelo de detección de calibradores, permitiendo la medición automática de la LC. El conjunto de datos incluyó a 311 mujeres embarazadas de dos centros especializados en salud materno-fetal. El modelo de segmentación fue evaluado utilizando el coeficiente de Dice, la distancia media de superficie (MSD) y la tasa de error de area (AER), logrando una puntuación Dice de 0.83 (IC del 95 %: 0.78–0.88), una MSD de 8.89 mm (IC del 95 %: 5.47–12.31), y una AER de 607 mm² (IC del 95 %: 402–812). Para la medición de la LC, el modelo basado en CNN obtuvo un error relativo (RE) de 0.19 (IC del 95 %: 0.14, 0.25) en la fase de prueba. Si bien las estimaciones fueron cercanas a la longitud real, se observaron algunas discrepancias debido a errores de segmentación y a la variabilidad en la colocaci ´on de los calibradores. Este estudio representa un avance hacia la automatización de la medición de la LC, reduciendo la subjetividad. | |
dc.description.abstractenglish | Preterm birth (PTB) is a major global public health concern, affecting approximately 15 million pregnancies annually. One of the most reliable indicators of PTB risk is cervical length (CL), which is manually measured in transvaginal ultrasound (TVUS) images. However, manual measurements are subject to inter-operator variability, limiting their reliability. To improve consistency and automation, this study proposes a deep learning-based approach for CL evaluation. A CNN-based model was developed to detect caliper positions and estimate CL. To achieve this, the mid-third of the cervix in first-trimester TVUS images was first segmented using a U-Net network. These segmentations were then used to train the caliper detection model, enabling the automated measurement of CL. The dataset included 311 pregnant women from two specialized maternal-fetal health centers. The segmentation model was evaluated using Dice coefficient, mean surface distance (MSD), and area error rate (AER), achieving a Dice score of 0.83 (95 % CI: 0.78–0.88), an MSD of 8.89 mm (95 % CI: 5.47–12.31), and an AER of 607 mm² (95 % CI: 402–812). For CL measurement, the CNN-based model obtained a relative error (RE) of 0.19 (95 % CI: 0.14, 0.25) in the test phase. While the estimates were close to the actual length, some discrepancies remained due to segmentation errors and variability in caliper placement. This study represents a step toward automating CL measurement, reducing subjectivity, and improving PTB risk detection in early pregnancy. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electrónico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/45569 | |
dc.language.iso | eng | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Electrónica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Parto prematuro | |
dc.subject | longitud cervical | |
dc.subject | ecografía transvaginal | |
dc.subject | redes neuronales convolucionales | |
dc.subject | detección de calibrador | |
dc.subject | segmentación de imágenes | |
dc.subject.keyword | Preterm birth | |
dc.subject.keyword | cervical length | |
dc.subject.keyword | transvaginal ultrasound | |
dc.subject.keyword | convolutional neural networks | |
dc.subject.keyword | Caliper detection | |
dc.subject.keyword | image segmentation. | |
dc.title | ALGORITMO PARA LA MEDICIÓN AUTOMÁTICA DE LA LONGITUD CERVICAL A PARTIR DE IMÁGENES DE ULTRASONIDO TRANSVAGINAL | |
dc.title.english | ALGORITHM FOR THE AUTOMATIC MEASUREMENT OF CERVICAL LENGTH FROM TRANSVAGINAL ULTRASOUND IMAGES | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Apendices.pdf
- Size:
- 67.35 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 95.79 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 79.05 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: