dc.description.abstractEste trabajo de grado analiza una estrategia backward-forward implementada en un sistema radial monofásico de baja tensión de 13 barras con luminarias LED de 15 W. Para ello, se modela el sistema utilizando modelos de carga en el dominio de la frecuencia como el de matriz de admitancias armónicamente acopladas (HCAM), y el equivalente de Norton (NEM), y en el dominio del tiempo un modelo circuital equivalente optimizado mediante la estimación de parámetros óptimos (OPE) y posteriormente implementado en MATLAB (Simulink). Para obtener las medidas, se realizan experimentos como el de un armónico a la vez para modelar la carga LED de 15 W. Además, este mismo sistema de 13 barras se implementa en el laboratorio con el fin de tomar medidas y comparar los resultados obtenidos en el dominio del tiempo, la frecuencia y las medidas de laboratorio en diferentes escenarios de carga y tensiones de alimentación. Se parte del estudio de trabajos de grado previos que sirven como base para plantear un marco teórico, metodológico y de resultados, representando las diferencias entre los resultados simulados y medidos. Para ello se propone la estimación de un error medio cuadrático (MSE) que se encuentra entre el 0,583% y el 13,99%. Estos valores de MSE indican que, aunque el modelo presenta una precisión aceptable en la mayoría de los casos, existen escenarios específicos donde la discrepancia entre los resultados simulados y medidos es más significativa.
dc.description.abstractenglishThis degree work analyzes a backward-forward strategy implemented in a 13-bar single-phase low voltage radial system with 15 W LED luminaires. For this purpose, the system is modeled using frequency domain load models such as the harmonically coupled admittance matrix (HCAM), and the Norton equivalent (NEM), and in the time domain an equivalent circuit model optimized by optimal parameter estimation (OPE) and subsequently implemented in MATLAB (Simulink). To obtain the measurements, experiments such as one harmonic at a time are performed to model the 15 W LED load. In addition, this same 13-bar system is implemented in the laboratory in order to take measurements and compare the results obtained in time domain, frequency and laboratory measurements in different load scenarios and supply voltages. We start from the study of previous degree works that serve as a basis to propose a theoretical, methodological and results framework, representing the differences between simulated and measured results. For this purpose, the estimation of a mean squared error (MSE) between 0.583% and 13.99% is proposed. These MSE values indicate that, although the model presents an acceptable accuracy in most cases, there are specific scenarios where the discrepancy between simulated and measured results is more significant.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Electricista
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/45500
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programIngeniería Eléctrica
dc.publisher.schoolEscuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectSistema radial
dc.subjectFlujo armónico
dc.subjectLuminarias tipo Led
dc.subjectEstrategia backward - forward
dc.subjectModelo en el dominio de la frecuencia
dc.subject.keywordRadial system
dc.subject.keywordHarmonic flow
dc.subject.keywordLED luminaries
dc.subject.keywordBackward - forward estrategy
dc.subject.keywordFrequency dominion model
dc.titleAnálisis de una Estrategia Backward – Fordward para el Flujo Armónico de un Sistema Radial Monofásico Utilizando Luminarias Tipo Led.
dc.title.englishAnalysis of a Backward-Forward Strategy for Harmonic Flow in a Single-Phase Radial System Using LED Luminaires.
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
260.48 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
340.39 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
1.54 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: