Reforzamiento estructural de columnas con la adición de muro patín

dc.contributor.advisorCruz Hernandez, Ricardo Alfredo
dc.contributor.authorRincón Ayala, Miguel Antonio
dc.date.accessioned2024-03-03T16:16:39Z
dc.date.available2006
dc.date.available2024-03-03T16:16:39Z
dc.date.created2006
dc.date.issued2006
dc.description.abstractEn la práctica cada vez más son efectuadas conexiones entre elementos de concreto reforzado con varillas de refuerzo postinstaladas con un mortero adhesivo en huecos perforados en el concreto existente. Existen en la práctica de diseño criterios diversos respecto al cálculo del anclaje de las varillas y la tendencia es usar longitudes de anclaje pequeñas, mucho menores a las que normalmente exigen los códigos de diseño de concreto reforzado (DIN1045/EC2/NSR-98). El objetivo es dar información sobre el comportamiento de anclajes postinstalados con morteros adhesivos y criterios de diseño de varillas ancladas al concreto. Usando morteros apropiados no hay diferencia significativa en la capacidad de carga de una conexión con respecto a refuerzo preinstalado. (Excepciones: fisuras longitudinales, refuerzo transversal insuficiente, temperatura) Diseño de anclaje de varillas simplificado: dimensionado de las longitudes de traslapo según DIN1045/EC2/NSR98. Con estas longitudes se garantiza falla del acero o falla dúctil. Diseño de anclaje de varillas más exacto. Las características geométricas existentes son tenidas en cuenta y no las distancias mínimas entre ejes y al borde dadas por los códigos de concreto reforzado: menores longitudes de anclaje y traslapo. La resistencia de adherencia depende de la limpieza del hueco, especialmente en concreto húmedo. Anclaje de varillas sin refuerzo de conexión solo se permite en varillas a compresión. Anclajes con longitudes de anclaje pequeñas, menores a aproximadamente 15 ds, y sin refuerzo de conexión se comportan como anclajes adheridos y deben diseñarse como tal. En tal caso la falla puede ser dúctil o frágil. No puede generalizaser el diseño de un sistema de anclaje; según el caso el diseñador analizará el comportamiento del sistema de anclaje y de acuerdo a esto efectuar el diseño, elección del personal de obra, el uso de equipos especiales, de adhesivos que cumplen especificaciones para el caso de anclajes estructurales.
dc.description.abstractenglishConnections between reinforced concrete elements and post-installed reinforcing rods in an adhesive mortar in holes drilled in the existing concrete are conducted and completed in the practice with more frequency each time. Design practice includes diverse criteria regarding anchoring calculation of rods. The current trend is to utilize small anchoring lengths, much less to the lengths normally demanded by reinforced concrete design codes ( (DIN1045/EC2/NSR-98). The objective is to provide information about the behavior of post-installed anchoring with adhesive mortars and design criteria for anchored rods into the concrete. No significant differences in load capacity of a connection regarding a pre-installed reinforcement has been observed using the appropriate mortars (exception: longitudinal fissuring, insufficient transversal reinforcement, temperature). Simplified anchoring design of rods: dimensioning of overlap according to DIN1045/EC2/NSR-98. These lengths ensure steel fault or ductile fault. Design of a more accurate rod anchoring. Geometric characteristics are considered and not the minimum distances between axis and the edge given by the reinforced concrete codes: less anchoring and overlap lengths. Adherence strength depends on hole cleanness, specially in wet concrete. Anchoring of rods without connection reinforcement is only allowed in compression rods. Small Πlength anchoring of approximately 15 ds,, without connection reinforcement, behave as adhered anchoring and must be designed as such. In this case, faults can be ductile or fragile. Design of an anchoring system cannot be generalized. According to the case, designers analyze the behavior of the anchoring system and, based on that, proceed to design, select work personnel, utilization of special equipment and adhesives conforming to the specifications for structural anchoring.
dc.description.degreelevelEspecialización
dc.description.degreenameEspecialista en Estructuras
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/19393
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programEspecialización en Estructuras
dc.publisher.schoolEscuela de Ingeniería Civil
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectAnclajes Postinstalados
dc.subjectMorteros Adhesivos
dc.subjectRefuerzo De Conexión
dc.subjectResistencia De
dc.subject.keywordPost-Installed Anchoring
dc.subject.keywordAdhesive Mortars. Connection Reinforcement. Adherence Strength
dc.titleReforzamiento estructural de columnas con la adición de muro patín
dc.title.englishStructural reinforcement of columns with the addition of flange wallfl.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Documento.pdf
Size:
917.86 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
75.39 KB
Format:
Adobe Portable Document Format