Diseño de un banco de medida de parámetros eléctricos usando medidores comerciales
dc.contributor.advisor | Osma Pinto, German Alfonso | |
dc.contributor.advisor | Ordoñez Plata, Gabriel | |
dc.contributor.author | González Laverde, Julián Andrés | |
dc.contributor.author | Prince Acelas, Juán Sebastián | |
dc.contributor.author | Ibarra Manzano, Carlos Eduardo | |
dc.contributor.evaluator | Duarte Gualdrón, Cesar Antonio | |
dc.contributor.evaluator | Adarme López, Edinson Fabián | |
dc.date.accessioned | 2024-08-20T14:40:57Z | |
dc.date.available | 2024-08-20T14:40:57Z | |
dc.date.created | 2024-08-16 | |
dc.date.issued | 2024-08-16 | |
dc.description.abstract | En este trabajo de investigación se desarrolla el diseño de un banco de medida de parámetros eléctricos que tiene como fin la caracterización de cargas monofásicas, la comparación de los datos obtenidos usando el medidor comercial YTL DDS 1Y y un medidor de referencia, que en este caso es el analizador de redes PQube 3, para así por medio de una interfaz lograr la visualización de los parámetros establecidos en el Standard IEEE 1459-2010 para sistemas monofásicos, que permite cuantificar diferentes parámetros de potencia allí expuestos; se hace posible el análisis de magnitudes de potencia y mediante el uso de gráficas lograr visualizar formas de onda y la influencia de armónicos en la carga medida. El diseño del banco de medida cuenta con espacios destinados a la instalación de cargas como lo son luminarias mediante tres plafones rosca E27, dos tomacorrientes para la conexión de electrodomésticos de uso diario y se dispone de una bornera tipo jack banana para la conexión de otra carga que se requiera medir. El uso de un medidor como lo es el analizador de redes PQube 3 permite tener una referencia de gran exactitud para que el usuario pueda crear una comparación de la precisión de los datos medidos con el medidor comercial YTL DDS 1Y, conectado mediante puerto RS485 utilizando un concentrador de datos para permitir la transferencia de las medidas mediante protocolo MODBUS RTU, estos datos se procesan, se muestran al usuario y se genera un reporte de comparación de los parámetros medidos tanto con el medidor PQube 3 como con el medidor comercial en la interfaz de usuario desarrollada. | |
dc.description.abstractenglish | In this research work, the design of a bank for measuring electrical parameters is developed, whose purpose is the characterization of single-phase loads, the comparison of the data obtained using a commercial meter YTL DDS 1Y and a reference meter, which in this case is the grid analyzer PQube 3, in order to achieve, through an interface, the visualization of the parameters established in the IEEE Standard 1459-2010 for single-phase systems, which allows quantifying different power parameters exposed there; allowing he analysis of power magnitudes and through the use of graphs it is possible to visualize waveforms and the influence of harmonics on the measured load. The design of the measurement bank has spaces intended for the installation of loads such as luminaires using E27 threaded ceiling lights, outlets for connecting appliances for daily use and is available of a banana jack type terminal block for connecting any other load that requires measurement. The use of a meter such as the PQube 3 network analyzer allows for a highly accurate reference so that the user can create a comparison of the precision of the measured data with the commercial meter YTL DDS 1Y, connected through an RS485 port using a data concentrator to allow measure transfer via MODBUS RTU protocol, these data are processed, shown to the user and a comparison report of the parameters measured with both the PQube 3 meter and the commercial meter is generated in the developed user interface. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electricista | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/43787 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Eléctrica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-SinDerivadas 2.5 Colombia (CC BY-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Medidor de energía | |
dc.subject | MODBUS | |
dc.subject | Interfaz | |
dc.subject | PQube3 | |
dc.subject | YTL DDS 1Y | |
dc.subject.keyword | Energy meter | |
dc.subject.keyword | MODBUS | |
dc.subject.keyword | Interface | |
dc.subject.keyword | PQube3 | |
dc.subject.keyword | YTL DDS 1Y | |
dc.title | Diseño de un banco de medida de parámetros eléctricos usando medidores comerciales | |
dc.title.english | Design of a Measurement Bench for Electrical Parameters Using Commercial Meters | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 218.33 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 91.05 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: