Publicación: Espectros generalizados de deriva para Bucaramanga usando un modelo continuo
| dc.contributor.advisor | Maldonado Rondon, Esperanza | |
| dc.contributor.author | Gelvez Munévar, Jorge Fabian | |
| dc.contributor.author | Ortiz Aponte, Rony Alexander | |
| dc.date.accessioned | 2024-03-03T17:37:20Z | |
| dc.date.available | 2009 | |
| dc.date.available | 2024-03-03T17:37:20Z | |
| dc.date.created | 2009 | |
| dc.date.issued | 2009 | |
| dc.description.abstract | El espectro generalizado de derivas de entrepiso es una grafica del periodo fundamental del edificio, versus demanda máxima de deriva. Por lo tanto, este espectro ofrece una indicación directa de la máxima deriva de entrepiso en edificaciones con diferentes periodos de vibración (Miranda y Akkar, 2006). Muchos estudios han mostrado que la razón de deriva de entrepiso, definida como la diferencia en el desplazamiento de 2 pisos (niveles) consecutivos, es el parámetro que mejor está correlacionado con el daño en una estructura (Algan 1982; Sozen 1983; Moehle 1984; Qi y Moehle 1991; Moehle 1994; Gulkan y Sozen 1999; Bozorgnia y Bertero 2001). Por esta razón los espectros de derivas son herramientas muy útiles para los ingenieros estructurales. Para calcular los espectros generalizados de deriva se utilizo el modelo continuo simplificado propuesto por Miranda y Akkar (2006), que consiste en una viga de flexión en voladizo y una viga de cortante en voladizo que están conectadas por miembros axialmente rígidos. Este modelo continuo tiene en cuenta deformaciones tipo cortante, deformaciones tipo flexión, y deformaciones intermedias que son las que más se parecen a las deformaciones presentadas por los edificios de varios pisos. Se calcularon espectros generalizados de derivas para edificaciones cuyo sistema de resistencia lateral consiste en pórticos resistentes a momentos, muros estructurales, y sistemas que combinan pórticos resistentes a momentos y muros de cortante. Estos espectros se calcularon utilizando los registros de sismos propuestos como amenaza para Bucaramanga por Ingeominas (2001). | |
| dc.description.abstractenglish | The generalized interstory drift spectrum is a plot of the fundamental period of the building versusmaxIDR. Hence it provides a direct indication of the peak interstory drift in buildings with different periods of vibration (Miranda and Akkar, 2006). Many studies have shown that the intestory drift ratio, defined as the difference in lateral displacements in between two consecutives normalized by the interstory height, is the response parameter that is best correlated with damage in buildings (Algan 1982; Sozen 1983; Moehle 1984; Qi and Moehle 1991; Moehle 1994; Gülkan and Sozen 1999; Bozorgnia and Bertero 2001). That is the reason why drift spectrums are very useful tools for structural engineers. Generalized drift spectrums were calculated using the Simplified Continuous Model proposed by Miranda and Akkar (2006) it consist of a flexural cantiléver beam and a shear caltilever beam connected by axially rigid members. This continuous model takes into account shear deformations, flexural deformations, and combined overall shear and flexural deformations that represent more closely deformation of multistory buildings. Generalized drift spectrums were calculated for buildings whose lateral resisting systems consist in moment-resisting frames, shear walls, and buildings with a combination of moment-resisting frames and shear walls. These spectrums were calculated using the seismic registers proposed by Ingeominas (2001) as a menace for Bucaramanga City. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Civil | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/22840 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Civil | |
| dc.publisher.school | Escuela de Ingeniería Civil | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Espectro | |
| dc.subject | Deriva | |
| dc.subject | Acelerograma | |
| dc.subject | Demanda de deriva | |
| dc.subject | Viga de cortante | |
| dc.subject | Viga de flexión. | |
| dc.subject.keyword | Spectrum | |
| dc.subject.keyword | Drift | |
| dc.subject.keyword | Accelerogram | |
| dc.subject.keyword | Drift Demand | |
| dc.subject.keyword | Shear Beam | |
| dc.subject.keyword | Flexural | |
| dc.title | Espectros generalizados de deriva para Bucaramanga usando un modelo continuo | |
| dc.title.english | Generalized interstory drift spectrums for bucaramanga city using a continous model. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |